CALIBRATION OF ULTRASONIC FLOWMETER FOR WI-FI NETWORK WITH THE HELP OF WEB BROWSER

Objectives. The purpose of the work was to change the method of signal transmission containing metrological information from industrial time-pulse ultrasonic gas flow meter to a compu-ting device (CD). It was planned to expand the range of devices serving as gas flow calculators. A hardware-software...

Full description

Bibliographic Details
Main Authors: M. A. Velichko, Yu. P. Gladkikh, O. N. Satler
Format: Article
Language:Russian
Published: Dagestan State Technical University 2019-05-01
Series:Вестник Дагестанского государственного технического университета: Технические науки
Subjects:
Online Access:https://vestnik.dgtu.ru/jour/article/view/594
_version_ 1797697844860157952
author M. A. Velichko
Yu. P. Gladkikh
O. N. Satler
author_facet M. A. Velichko
Yu. P. Gladkikh
O. N. Satler
author_sort M. A. Velichko
collection DOAJ
description Objectives. The purpose of the work was to change the method of signal transmission containing metrological information from industrial time-pulse ultrasonic gas flow meter to a compu-ting device (CD). It was planned to expand the range of devices serving as gas flow calculators. A hardware-software complex (HSC) for automatic calibration / verification of ultrasonic flowmeters was to be developed. This HSC should work equally well on different operating systems. The information exchange between the CD and the flowmeter was to be carried out wirelessly.Method. The Wi-Fi Pro-tocol was used as a wireless Protocol. The energy-efficient ESP8266 controller was chosen as micro-controller to provide the functionality of Wi-Fi. The ESP8266 board acted as a Wi-Fi access point on the network to which CD was connected for data exchange. The ESP8266 microcontroller also served as a HTTP server. Exchange of metrological and other information was carried out by GET-requests. Given the need for continuous flow measurements and simultaneous communication between the user and the flow meter, requests to the server were transmitted using AJAX technology. The software part of the APK consisted of 3 programs: a program that measured the flow and transmitted the information further to the ESP8266 microcontroller, a server program recorded in ESP8266, providing a response to the requests of CD users, and the client program installed on the CD. The article discusses the key points of the HSC.Result. As a result of this work, the HSC was processed for calibration/verification of ultrasonic gas flow meters. For the first time this process for industrial flow meters was implemented using the ESP8266Wi-Fi controller as an access point. As a WU, it became possible to use any desktop or laptop computer or mobile device with a modern browser.Conclusion. The method proposed in the paper significantly simplified the data exchange between the VU and the flowmeter, reduced the cost of software development due to the common approach for different operating systems.
first_indexed 2024-03-12T03:45:54Z
format Article
id doaj.art-ca744c96b61844c09da16463e41bc4fc
institution Directory Open Access Journal
issn 2073-6185
2542-095X
language Russian
last_indexed 2024-03-12T03:45:54Z
publishDate 2019-05-01
publisher Dagestan State Technical University
record_format Article
series Вестник Дагестанского государственного технического университета: Технические науки
spelling doaj.art-ca744c96b61844c09da16463e41bc4fc2023-09-03T12:57:58ZrusDagestan State Technical UniversityВестник Дагестанского государственного технического университета: Технические науки2073-61852542-095X2019-05-014539410210.21822/2073-6185-2018-45-3-94-102452CALIBRATION OF ULTRASONIC FLOWMETER FOR WI-FI NETWORK WITH THE HELP OF WEB BROWSERM. A. Velichko0Yu. P. Gladkikh1O. N. Satler2Белгородский государственный национальный исследовательский университет.Белгородский государственный национальный исследовательский университет.Белгородский государственный национальный исследовательский университет.Objectives. The purpose of the work was to change the method of signal transmission containing metrological information from industrial time-pulse ultrasonic gas flow meter to a compu-ting device (CD). It was planned to expand the range of devices serving as gas flow calculators. A hardware-software complex (HSC) for automatic calibration / verification of ultrasonic flowmeters was to be developed. This HSC should work equally well on different operating systems. The information exchange between the CD and the flowmeter was to be carried out wirelessly.Method. The Wi-Fi Pro-tocol was used as a wireless Protocol. The energy-efficient ESP8266 controller was chosen as micro-controller to provide the functionality of Wi-Fi. The ESP8266 board acted as a Wi-Fi access point on the network to which CD was connected for data exchange. The ESP8266 microcontroller also served as a HTTP server. Exchange of metrological and other information was carried out by GET-requests. Given the need for continuous flow measurements and simultaneous communication between the user and the flow meter, requests to the server were transmitted using AJAX technology. The software part of the APK consisted of 3 programs: a program that measured the flow and transmitted the information further to the ESP8266 microcontroller, a server program recorded in ESP8266, providing a response to the requests of CD users, and the client program installed on the CD. The article discusses the key points of the HSC.Result. As a result of this work, the HSC was processed for calibration/verification of ultrasonic gas flow meters. For the first time this process for industrial flow meters was implemented using the ESP8266Wi-Fi controller as an access point. As a WU, it became possible to use any desktop or laptop computer or mobile device with a modern browser.Conclusion. The method proposed in the paper significantly simplified the data exchange between the VU and the flowmeter, reduced the cost of software development due to the common approach for different operating systems.https://vestnik.dgtu.ru/jour/article/view/594ультразвуковой расходомерhttpuartwi-fiмикроконтроллерesp8266arduino
spellingShingle M. A. Velichko
Yu. P. Gladkikh
O. N. Satler
CALIBRATION OF ULTRASONIC FLOWMETER FOR WI-FI NETWORK WITH THE HELP OF WEB BROWSER
Вестник Дагестанского государственного технического университета: Технические науки
ультразвуковой расходомер
http
uart
wi-fi
микроконтроллер
esp8266
arduino
title CALIBRATION OF ULTRASONIC FLOWMETER FOR WI-FI NETWORK WITH THE HELP OF WEB BROWSER
title_full CALIBRATION OF ULTRASONIC FLOWMETER FOR WI-FI NETWORK WITH THE HELP OF WEB BROWSER
title_fullStr CALIBRATION OF ULTRASONIC FLOWMETER FOR WI-FI NETWORK WITH THE HELP OF WEB BROWSER
title_full_unstemmed CALIBRATION OF ULTRASONIC FLOWMETER FOR WI-FI NETWORK WITH THE HELP OF WEB BROWSER
title_short CALIBRATION OF ULTRASONIC FLOWMETER FOR WI-FI NETWORK WITH THE HELP OF WEB BROWSER
title_sort calibration of ultrasonic flowmeter for wi fi network with the help of web browser
topic ультразвуковой расходомер
http
uart
wi-fi
микроконтроллер
esp8266
arduino
url https://vestnik.dgtu.ru/jour/article/view/594
work_keys_str_mv AT mavelichko calibrationofultrasonicflowmeterforwifinetworkwiththehelpofwebbrowser
AT yupgladkikh calibrationofultrasonicflowmeterforwifinetworkwiththehelpofwebbrowser
AT onsatler calibrationofultrasonicflowmeterforwifinetworkwiththehelpofwebbrowser