Locating partial discharge in insulation of high voltage electric machines using circuit-field model analysis
This paper uses circuit and field models incorporated into the finite element analysis to detect and locate partial discharges (PDs) in winding insulation of high voltage electric machines. Locating PDs with KHz-MHz frequency components is enabled by fast transient models. For this purpose, a PD cur...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | fas |
Published: |
Semnan University
2021-06-01
|
Series: | مجله مدل سازی در مهندسی |
Subjects: | |
Online Access: | https://modelling.semnan.ac.ir/article_5209_5dee8974074c91f420d6618ad1e1b468.pdf |
_version_ | 1797296559714467840 |
---|---|
author | hamidreza khezri hamidreza akbari seyedamin saied |
author_facet | hamidreza khezri hamidreza akbari seyedamin saied |
author_sort | hamidreza khezri |
collection | DOAJ |
description | This paper uses circuit and field models incorporated into the finite element analysis to detect and locate partial discharges (PDs) in winding insulation of high voltage electric machines. Locating PDs with KHz-MHz frequency components is enabled by fast transient models. For this purpose, a PD current pulse with MHz frequency component is injected into each winding turn of the very fast transient model of a squirrel cage induction machine 6KV/250KW. To detect the PD pulse, all field and circuit equations are presented and solved to obtain the system final matrix. In addition, to investigate the model accuracy, the induction machine windings are also simulated using the multi conductor transmission line circuit model. After injecting the PD pulse, the discharge locations are estimated using current analysis. The results are then compared with the proposed model, confirming the reasonable accuracy of the model in estimating the location of PD with high frequency components. |
first_indexed | 2024-03-07T22:06:31Z |
format | Article |
id | doaj.art-cb193b3aaf394cbda0b82f5f4906c28b |
institution | Directory Open Access Journal |
issn | 2008-4854 2783-2538 |
language | fas |
last_indexed | 2024-03-07T22:06:31Z |
publishDate | 2021-06-01 |
publisher | Semnan University |
record_format | Article |
series | مجله مدل سازی در مهندسی |
spelling | doaj.art-cb193b3aaf394cbda0b82f5f4906c28b2024-02-23T19:08:35ZfasSemnan Universityمجله مدل سازی در مهندسی2008-48542783-25382021-06-0119658110110.22075/jme.2021.21684.19875209Locating partial discharge in insulation of high voltage electric machines using circuit-field model analysishamidreza khezri0hamidreza akbari1seyedamin saied2Department of Electrical Engineering, Yazd Branch, Islamic Azad University, Yazd, IranDepartment of Electrical Engineering, Yazd Branch, Islamic Azad University, Yazd, IranDepartment of Electrical Engineering, Yazd Branch, Islamic Azad University, Yazd, IranThis paper uses circuit and field models incorporated into the finite element analysis to detect and locate partial discharges (PDs) in winding insulation of high voltage electric machines. Locating PDs with KHz-MHz frequency components is enabled by fast transient models. For this purpose, a PD current pulse with MHz frequency component is injected into each winding turn of the very fast transient model of a squirrel cage induction machine 6KV/250KW. To detect the PD pulse, all field and circuit equations are presented and solved to obtain the system final matrix. In addition, to investigate the model accuracy, the induction machine windings are also simulated using the multi conductor transmission line circuit model. After injecting the PD pulse, the discharge locations are estimated using current analysis. The results are then compared with the proposed model, confirming the reasonable accuracy of the model in estimating the location of PD with high frequency components.https://modelling.semnan.ac.ir/article_5209_5dee8974074c91f420d6618ad1e1b468.pdfmulti-conductor transmission line modelcircuit and field transient equationsfinite element analysispartial discharge locationhigh-voltage machines insulationcurrent analysis |
spellingShingle | hamidreza khezri hamidreza akbari seyedamin saied Locating partial discharge in insulation of high voltage electric machines using circuit-field model analysis مجله مدل سازی در مهندسی multi-conductor transmission line model circuit and field transient equations finite element analysis partial discharge location high-voltage machines insulation current analysis |
title | Locating partial discharge in insulation of high voltage electric machines using circuit-field model analysis |
title_full | Locating partial discharge in insulation of high voltage electric machines using circuit-field model analysis |
title_fullStr | Locating partial discharge in insulation of high voltage electric machines using circuit-field model analysis |
title_full_unstemmed | Locating partial discharge in insulation of high voltage electric machines using circuit-field model analysis |
title_short | Locating partial discharge in insulation of high voltage electric machines using circuit-field model analysis |
title_sort | locating partial discharge in insulation of high voltage electric machines using circuit field model analysis |
topic | multi-conductor transmission line model circuit and field transient equations finite element analysis partial discharge location high-voltage machines insulation current analysis |
url | https://modelling.semnan.ac.ir/article_5209_5dee8974074c91f420d6618ad1e1b468.pdf |
work_keys_str_mv | AT hamidrezakhezri locatingpartialdischargeininsulationofhighvoltageelectricmachinesusingcircuitfieldmodelanalysis AT hamidrezaakbari locatingpartialdischargeininsulationofhighvoltageelectricmachinesusingcircuitfieldmodelanalysis AT seyedaminsaied locatingpartialdischargeininsulationofhighvoltageelectricmachinesusingcircuitfieldmodelanalysis |