THE EFFICACY OF THE CABLES OF 6–110 KW WITH XLPE INSULATION. Part 2

The assessment of the suitability of cables of 6–110 kW with XLPE insulation in comparison with cables of the same voltage but possessing paper-oil insulation has been fulfilled on the basis of the method of multi-objective optimization that makes it possible to account not only the quantitative cha...

Full description

Bibliographic Details
Main Authors: M. A. Korotkevich, S. I. Podgaiskiy, A. V. Golomuzdov
Format: Article
Language:Russian
Published: Belarusian National Technical University 2017-11-01
Series:Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
Subjects:
Online Access:https://energy.bntu.by/jour/article/view/1094
_version_ 1797879763429228544
author M. A. Korotkevich
S. I. Podgaiskiy
A. V. Golomuzdov
author_facet M. A. Korotkevich
S. I. Podgaiskiy
A. V. Golomuzdov
author_sort M. A. Korotkevich
collection DOAJ
description The assessment of the suitability of cables of 6–110 kW with XLPE insulation in comparison with cables of the same voltage but possessing paper-oil insulation has been fulfilled on the basis of the method of multi-objective optimization that makes it possible to account not only the quantitative characteristics (of reduced costs), but also qualitative ones. As an indicator of the reliability of the cable line the maximum mean time to failure (the value inversely proportional to the parameter of succession of failures), which is an order more for cable lines with XLPE insulation than for cable lines with paper insulation, is adopted. A comprehensive assessment of the convenience of installation of cable lines revealed that the installation of cable with XLPE insulation features a 1.2–1.6 times easier installation as compared to three-wire (voltage 10 kW) and 1.4 times easier installation as compared to single-core oil-filled cables (voltage of 110 kW). The efficacy of the cables 6–110 kW with XLPE insulation is proved on the basis on the method of multi-objective optimization, that took into account as the costs for the construction and operation of cable lines and the reliability of its operation, ease of its installation and other quality indicators. If the goals taken into account are considered as equally important, the polyethylene-insulated cables for a voltage of 10–110 kW is more efficient as compared to three-wire (voltage 10 kW) and solid (110 kW) cables with paper insulation. Herewith, the cost of the cable with XLPE insulation may exceed the cost of cable with paper insulation up to two times. If the most important aim is to provide the minimum reduced costs for the construction and operation of the cable line, the use of cables with XLPE insulation for voltage of 10 kW is most advisable in individual cases.
first_indexed 2024-04-10T02:53:35Z
format Article
id doaj.art-cb589c4f65204c74b67fe54b1ea9eba6
institution Directory Open Access Journal
issn 1029-7448
2414-0341
language Russian
last_indexed 2024-04-10T02:53:35Z
publishDate 2017-11-01
publisher Belarusian National Technical University
record_format Article
series Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
spelling doaj.art-cb589c4f65204c74b67fe54b1ea9eba62023-03-13T07:41:50ZrusBelarusian National Technical UniversityIzvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika1029-74482414-03412017-11-0160650552210.21122/1029-7448-2017-60-6-505-5221055THE EFFICACY OF THE CABLES OF 6–110 KW WITH XLPE INSULATION. Part 2M. A. Korotkevich0S. I. Podgaiskiy1A. V. Golomuzdov2Белорусский национальный технический университетЭнергокомплектЭнергокомплектThe assessment of the suitability of cables of 6–110 kW with XLPE insulation in comparison with cables of the same voltage but possessing paper-oil insulation has been fulfilled on the basis of the method of multi-objective optimization that makes it possible to account not only the quantitative characteristics (of reduced costs), but also qualitative ones. As an indicator of the reliability of the cable line the maximum mean time to failure (the value inversely proportional to the parameter of succession of failures), which is an order more for cable lines with XLPE insulation than for cable lines with paper insulation, is adopted. A comprehensive assessment of the convenience of installation of cable lines revealed that the installation of cable with XLPE insulation features a 1.2–1.6 times easier installation as compared to three-wire (voltage 10 kW) and 1.4 times easier installation as compared to single-core oil-filled cables (voltage of 110 kW). The efficacy of the cables 6–110 kW with XLPE insulation is proved on the basis on the method of multi-objective optimization, that took into account as the costs for the construction and operation of cable lines and the reliability of its operation, ease of its installation and other quality indicators. If the goals taken into account are considered as equally important, the polyethylene-insulated cables for a voltage of 10–110 kW is more efficient as compared to three-wire (voltage 10 kW) and solid (110 kW) cables with paper insulation. Herewith, the cost of the cable with XLPE insulation may exceed the cost of cable with paper insulation up to two times. If the most important aim is to provide the minimum reduced costs for the construction and operation of the cable line, the use of cables with XLPE insulation for voltage of 10 kW is most advisable in individual cases.https://energy.bntu.by/jour/article/view/1094кабельные линии электропередачинапряжение 6–110 квизоляция из сшитого полиэтиленабумажно-масляная изоляциянадежностьудобство монтажамногоцелевая оптимизация
spellingShingle M. A. Korotkevich
S. I. Podgaiskiy
A. V. Golomuzdov
THE EFFICACY OF THE CABLES OF 6–110 KW WITH XLPE INSULATION. Part 2
Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
кабельные линии электропередачи
напряжение 6–110 кв
изоляция из сшитого полиэтилена
бумажно-масляная изоляция
надежность
удобство монтажа
многоцелевая оптимизация
title THE EFFICACY OF THE CABLES OF 6–110 KW WITH XLPE INSULATION. Part 2
title_full THE EFFICACY OF THE CABLES OF 6–110 KW WITH XLPE INSULATION. Part 2
title_fullStr THE EFFICACY OF THE CABLES OF 6–110 KW WITH XLPE INSULATION. Part 2
title_full_unstemmed THE EFFICACY OF THE CABLES OF 6–110 KW WITH XLPE INSULATION. Part 2
title_short THE EFFICACY OF THE CABLES OF 6–110 KW WITH XLPE INSULATION. Part 2
title_sort efficacy of the cables of 6 110 kw with xlpe insulation part 2
topic кабельные линии электропередачи
напряжение 6–110 кв
изоляция из сшитого полиэтилена
бумажно-масляная изоляция
надежность
удобство монтажа
многоцелевая оптимизация
url https://energy.bntu.by/jour/article/view/1094
work_keys_str_mv AT makorotkevich theefficacyofthecablesof6110kwwithxlpeinsulationpart2
AT sipodgaiskiy theefficacyofthecablesof6110kwwithxlpeinsulationpart2
AT avgolomuzdov theefficacyofthecablesof6110kwwithxlpeinsulationpart2
AT makorotkevich efficacyofthecablesof6110kwwithxlpeinsulationpart2
AT sipodgaiskiy efficacyofthecablesof6110kwwithxlpeinsulationpart2
AT avgolomuzdov efficacyofthecablesof6110kwwithxlpeinsulationpart2