Evaluation of balloon and satellite water vapour measurements in the Southern tropical and subtropical UTLS during the HIBISCUS campaign

Balloon water vapour in situ and remote measurements in the tropical upper troposphere and lower stratosphere (UTLS) obtained during the HIBISCUS campaign around 20° S in Brazil in February–March 2004 using a tunable diode laser (μSDLA), a surface acoustic wave (SAW) and a Vis-NIR solar...

Full description

Bibliographic Details
Main Authors: N. Montoux, B. Morel, H. Bencherif, J. P. Burrows, S. Dhomse, A. Rozanov, R. L. Jones, G. Durry, F. Lefèvre, J.-P. Pommereau, A. Hauchecorne
Format: Article
Language:English
Published: Copernicus Publications 2009-07-01
Series:Atmospheric Chemistry and Physics
Online Access:http://www.atmos-chem-phys.net/9/5299/2009/acp-9-5299-2009.pdf
_version_ 1818205948455419904
author N. Montoux
B. Morel
H. Bencherif
J. P. Burrows
S. Dhomse
A. Rozanov
R. L. Jones
G. Durry
F. Lefèvre
J.-P. Pommereau
A. Hauchecorne
author_facet N. Montoux
B. Morel
H. Bencherif
J. P. Burrows
S. Dhomse
A. Rozanov
R. L. Jones
G. Durry
F. Lefèvre
J.-P. Pommereau
A. Hauchecorne
author_sort N. Montoux
collection DOAJ
description Balloon water vapour in situ and remote measurements in the tropical upper troposphere and lower stratosphere (UTLS) obtained during the HIBISCUS campaign around 20° S in Brazil in February–March 2004 using a tunable diode laser (μSDLA), a surface acoustic wave (SAW) and a Vis-NIR solar occultation spectrometer (SAOZ) on a long duration balloon, have been used for evaluating the performances of satellite borne remote water vapour instruments available at the same latitude and measurement period. In the stratosphere, HALOE displays the best precision (2.5%), followed by SAGE II (7%), MIPAS (10%), SAOZ (20–25%) and SCIAMACHY (35%), all of which show approximately constant H<sub>2</sub>O mixing ratios between 20–25 km. Compared to HALOE of ±10% accuracy between 0.1–100 hPa, SAGE II and SAOZ show insignificant biases, MIPAS is wetter by 10% and SCIAMACHY dryer by 20%. The currently available GOMOS profiles of 25% precision show a positive vertical gradient in error for identified reasons. Compared to these, the water vapour of the Reprobus Chemistry Transport Model, forced at pressures higher than 95 hPa by the ECMWF analyses, is dryer by about 1 ppmv (20%). <br><br> In the lower stratosphere between 16–20 km, most notable features are the steep degradation of MIPAS precision below 18 km, and the appearance of biases between instruments far larger than their quoted total uncertainty. HALOE and SAGE II (after spectral adjustment for reducing the bias with HALOE at northern mid-latitudes) both show decreases of water vapour with a minimum at the tropopause not seen by other instruments or the model, possibly attributable to an increasing error in the HALOE altitude registration. Between 16–18 km where the water vapour concentration shows little horizontal variability, and where the μSDLA balloon measurements are not perturbed by outgassing, the average mixing ratios reported by the remote sensing instruments are substantially lower than the 4–5 ppmv observed by the μSDLA. Differences between μSDLA and HALOE and SAGE II (of the order of −2 ppmv), SCIAMACHY, MIPAS and GOMOS (−1 ppmv) and SAOZ (−0.5 ppmv), exceed the 10% uncertainty of μSDLA, implying larger systematic errors than estimated for the various instruments. <br><br> In the upper troposphere, where the water vapour concentration is highly variable, AIRS v5 appears to be the most consistent within its 25% uncertainty with balloon in-situ measurements as well as ECMWF. Most of the remote measurements show less reliability in the upper troposphere, losing sensitivity possibly because of absorption line saturation in their spectral ranges (HALOE, SAGE II and SCIAMACHY), instrument noise exceeding 100% (MIPAS) or imperfect refraction correction (GOMOS). An exception is the SAOZ-balloon, employing smaller H<sub>2</sub>O absorption bands in the troposphere.
first_indexed 2024-12-12T04:05:14Z
format Article
id doaj.art-cc7ac91986c34064b0a20a529f3d593a
institution Directory Open Access Journal
issn 1680-7316
1680-7324
language English
last_indexed 2024-12-12T04:05:14Z
publishDate 2009-07-01
publisher Copernicus Publications
record_format Article
series Atmospheric Chemistry and Physics
spelling doaj.art-cc7ac91986c34064b0a20a529f3d593a2022-12-22T00:38:48ZengCopernicus PublicationsAtmospheric Chemistry and Physics1680-73161680-73242009-07-0191452995319Evaluation of balloon and satellite water vapour measurements in the Southern tropical and subtropical UTLS during the HIBISCUS campaignN. MontouxB. MorelH. BencherifJ. P. BurrowsS. DhomseA. RozanovR. L. JonesG. DurryF. LefèvreJ.-P. PommereauA. HauchecorneBalloon water vapour in situ and remote measurements in the tropical upper troposphere and lower stratosphere (UTLS) obtained during the HIBISCUS campaign around 20° S in Brazil in February–March 2004 using a tunable diode laser (μSDLA), a surface acoustic wave (SAW) and a Vis-NIR solar occultation spectrometer (SAOZ) on a long duration balloon, have been used for evaluating the performances of satellite borne remote water vapour instruments available at the same latitude and measurement period. In the stratosphere, HALOE displays the best precision (2.5%), followed by SAGE II (7%), MIPAS (10%), SAOZ (20–25%) and SCIAMACHY (35%), all of which show approximately constant H<sub>2</sub>O mixing ratios between 20–25 km. Compared to HALOE of ±10% accuracy between 0.1–100 hPa, SAGE II and SAOZ show insignificant biases, MIPAS is wetter by 10% and SCIAMACHY dryer by 20%. The currently available GOMOS profiles of 25% precision show a positive vertical gradient in error for identified reasons. Compared to these, the water vapour of the Reprobus Chemistry Transport Model, forced at pressures higher than 95 hPa by the ECMWF analyses, is dryer by about 1 ppmv (20%). <br><br> In the lower stratosphere between 16–20 km, most notable features are the steep degradation of MIPAS precision below 18 km, and the appearance of biases between instruments far larger than their quoted total uncertainty. HALOE and SAGE II (after spectral adjustment for reducing the bias with HALOE at northern mid-latitudes) both show decreases of water vapour with a minimum at the tropopause not seen by other instruments or the model, possibly attributable to an increasing error in the HALOE altitude registration. Between 16–18 km where the water vapour concentration shows little horizontal variability, and where the μSDLA balloon measurements are not perturbed by outgassing, the average mixing ratios reported by the remote sensing instruments are substantially lower than the 4–5 ppmv observed by the μSDLA. Differences between μSDLA and HALOE and SAGE II (of the order of −2 ppmv), SCIAMACHY, MIPAS and GOMOS (−1 ppmv) and SAOZ (−0.5 ppmv), exceed the 10% uncertainty of μSDLA, implying larger systematic errors than estimated for the various instruments. <br><br> In the upper troposphere, where the water vapour concentration is highly variable, AIRS v5 appears to be the most consistent within its 25% uncertainty with balloon in-situ measurements as well as ECMWF. Most of the remote measurements show less reliability in the upper troposphere, losing sensitivity possibly because of absorption line saturation in their spectral ranges (HALOE, SAGE II and SCIAMACHY), instrument noise exceeding 100% (MIPAS) or imperfect refraction correction (GOMOS). An exception is the SAOZ-balloon, employing smaller H<sub>2</sub>O absorption bands in the troposphere.http://www.atmos-chem-phys.net/9/5299/2009/acp-9-5299-2009.pdf
spellingShingle N. Montoux
B. Morel
H. Bencherif
J. P. Burrows
S. Dhomse
A. Rozanov
R. L. Jones
G. Durry
F. Lefèvre
J.-P. Pommereau
A. Hauchecorne
Evaluation of balloon and satellite water vapour measurements in the Southern tropical and subtropical UTLS during the HIBISCUS campaign
Atmospheric Chemistry and Physics
title Evaluation of balloon and satellite water vapour measurements in the Southern tropical and subtropical UTLS during the HIBISCUS campaign
title_full Evaluation of balloon and satellite water vapour measurements in the Southern tropical and subtropical UTLS during the HIBISCUS campaign
title_fullStr Evaluation of balloon and satellite water vapour measurements in the Southern tropical and subtropical UTLS during the HIBISCUS campaign
title_full_unstemmed Evaluation of balloon and satellite water vapour measurements in the Southern tropical and subtropical UTLS during the HIBISCUS campaign
title_short Evaluation of balloon and satellite water vapour measurements in the Southern tropical and subtropical UTLS during the HIBISCUS campaign
title_sort evaluation of balloon and satellite water vapour measurements in the southern tropical and subtropical utls during the hibiscus campaign
url http://www.atmos-chem-phys.net/9/5299/2009/acp-9-5299-2009.pdf
work_keys_str_mv AT nmontoux evaluationofballoonandsatellitewatervapourmeasurementsinthesoutherntropicalandsubtropicalutlsduringthehibiscuscampaign
AT bmorel evaluationofballoonandsatellitewatervapourmeasurementsinthesoutherntropicalandsubtropicalutlsduringthehibiscuscampaign
AT hbencherif evaluationofballoonandsatellitewatervapourmeasurementsinthesoutherntropicalandsubtropicalutlsduringthehibiscuscampaign
AT jpburrows evaluationofballoonandsatellitewatervapourmeasurementsinthesoutherntropicalandsubtropicalutlsduringthehibiscuscampaign
AT sdhomse evaluationofballoonandsatellitewatervapourmeasurementsinthesoutherntropicalandsubtropicalutlsduringthehibiscuscampaign
AT arozanov evaluationofballoonandsatellitewatervapourmeasurementsinthesoutherntropicalandsubtropicalutlsduringthehibiscuscampaign
AT rljones evaluationofballoonandsatellitewatervapourmeasurementsinthesoutherntropicalandsubtropicalutlsduringthehibiscuscampaign
AT gdurry evaluationofballoonandsatellitewatervapourmeasurementsinthesoutherntropicalandsubtropicalutlsduringthehibiscuscampaign
AT flefevre evaluationofballoonandsatellitewatervapourmeasurementsinthesoutherntropicalandsubtropicalutlsduringthehibiscuscampaign
AT jppommereau evaluationofballoonandsatellitewatervapourmeasurementsinthesoutherntropicalandsubtropicalutlsduringthehibiscuscampaign
AT ahauchecorne evaluationofballoonandsatellitewatervapourmeasurementsinthesoutherntropicalandsubtropicalutlsduringthehibiscuscampaign