A study of brackish water membrane with ultrafiltration pretreatment in Indonesia’s coastal area

Water pollution and sea water intrusion to water sources in coastal areas result lack of provision safe drinking water by the drinking water regional company or coastal community. The existing water treatment plant that operated on brackish surface water or groundwater feed requires improving proces...

Full description

Bibliographic Details
Main Authors: Elis Hastuti, Made Widiadnyana Wardiha
Format: Article
Language:English
Published: University of Paraiba 2012-06-01
Series:Journal of Urban and Environmental Engineering
Subjects:
Online Access:http://dx.doi.org/10.4090/juee.2012.v6n1.010017
_version_ 1819113022624366592
author Elis Hastuti
Made Widiadnyana Wardiha
author_facet Elis Hastuti
Made Widiadnyana Wardiha
author_sort Elis Hastuti
collection DOAJ
description Water pollution and sea water intrusion to water sources in coastal areas result lack of provision safe drinking water by the drinking water regional company or coastal community. The existing water treatment plant that operated on brackish surface water or groundwater feed requires improving process. Membrane process could be a choice to treat the quality of brackish water to the level of potable water that designed to lower cost with high stabil flux and longer lifetime. This research focus on application of pilot plant of brackish water treatment using Ultrafiltration (UF) membrane-air lift system as pretreatment of Reverse Osmosis (RO) membrane-low pressure. Brackish water sources contain high colloidal and suspended solids that can cause fouling load of RO membranes and impair its performance. UF pretreatment operation tested by addition of compressed air into the feed (air lift system), resulted stable flux, reduces membrane fouling and low feed pressure. A flux of RO with UF pretreatment can produce drinking water of 30–61 L/m2∙hour. It was observed, the good quality of RO permeate resulted by using a pretreatment of UF–PS (Polysulfone-UF) with total dissolved solid rejection about 96–98% and color rejection about 99–100% at 5 or 8 bars of operation pressure. This paper concludes that performance of membrane technology with UF–air lift system pretreatment and RO membrane-low pressure could be accepted as condition of brackish water source in Indonesia coastal areas in producing drinking water.
first_indexed 2024-12-22T04:22:48Z
format Article
id doaj.art-cd168887470341b685abd1a9deff8847
institution Directory Open Access Journal
issn 1982-3932
language English
last_indexed 2024-12-22T04:22:48Z
publishDate 2012-06-01
publisher University of Paraiba
record_format Article
series Journal of Urban and Environmental Engineering
spelling doaj.art-cd168887470341b685abd1a9deff88472022-12-21T18:39:14ZengUniversity of ParaibaJournal of Urban and Environmental Engineering1982-39322012-06-01611017A study of brackish water membrane with ultrafiltration pretreatment in Indonesia’s coastal areaElis HastutiMade Widiadnyana WardihaWater pollution and sea water intrusion to water sources in coastal areas result lack of provision safe drinking water by the drinking water regional company or coastal community. The existing water treatment plant that operated on brackish surface water or groundwater feed requires improving process. Membrane process could be a choice to treat the quality of brackish water to the level of potable water that designed to lower cost with high stabil flux and longer lifetime. This research focus on application of pilot plant of brackish water treatment using Ultrafiltration (UF) membrane-air lift system as pretreatment of Reverse Osmosis (RO) membrane-low pressure. Brackish water sources contain high colloidal and suspended solids that can cause fouling load of RO membranes and impair its performance. UF pretreatment operation tested by addition of compressed air into the feed (air lift system), resulted stable flux, reduces membrane fouling and low feed pressure. A flux of RO with UF pretreatment can produce drinking water of 30–61 L/m2∙hour. It was observed, the good quality of RO permeate resulted by using a pretreatment of UF–PS (Polysulfone-UF) with total dissolved solid rejection about 96–98% and color rejection about 99–100% at 5 or 8 bars of operation pressure. This paper concludes that performance of membrane technology with UF–air lift system pretreatment and RO membrane-low pressure could be accepted as condition of brackish water source in Indonesia coastal areas in producing drinking water.http://dx.doi.org/10.4090/juee.2012.v6n1.010017Brackish waterUFPretreatmentAir lift systemRO
spellingShingle Elis Hastuti
Made Widiadnyana Wardiha
A study of brackish water membrane with ultrafiltration pretreatment in Indonesia’s coastal area
Journal of Urban and Environmental Engineering
Brackish water
UF
Pretreatment
Air lift system
RO
title A study of brackish water membrane with ultrafiltration pretreatment in Indonesia’s coastal area
title_full A study of brackish water membrane with ultrafiltration pretreatment in Indonesia’s coastal area
title_fullStr A study of brackish water membrane with ultrafiltration pretreatment in Indonesia’s coastal area
title_full_unstemmed A study of brackish water membrane with ultrafiltration pretreatment in Indonesia’s coastal area
title_short A study of brackish water membrane with ultrafiltration pretreatment in Indonesia’s coastal area
title_sort study of brackish water membrane with ultrafiltration pretreatment in indonesia s coastal area
topic Brackish water
UF
Pretreatment
Air lift system
RO
url http://dx.doi.org/10.4090/juee.2012.v6n1.010017
work_keys_str_mv AT elishastuti astudyofbrackishwatermembranewithultrafiltrationpretreatmentinindonesiascoastalarea
AT madewidiadnyanawardiha astudyofbrackishwatermembranewithultrafiltrationpretreatmentinindonesiascoastalarea
AT elishastuti studyofbrackishwatermembranewithultrafiltrationpretreatmentinindonesiascoastalarea
AT madewidiadnyanawardiha studyofbrackishwatermembranewithultrafiltrationpretreatmentinindonesiascoastalarea