Comparative study of old and new versions of treatment planning system using dose volume histogram indices of clinical plans

Recently, Eclipse treatment planning system (TPS) version 8.8 was upgraded to the latest version 13.6. It is customary that the vendor gives training on how to upgrade the existing software to the new version. However, the customer is provided less inner details about changes in the new software ver...

Full description

Bibliographic Details
Main Authors: Gangarapu Sri Krishna, Vuppu Srinivas, K M Ayyangar, Palreddy Yadagiri Reddy
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2016-01-01
Series:Journal of Medical Physics
Subjects:
Online Access:http://www.jmp.org.in/article.asp?issn=0971-6203;year=2016;volume=41;issue=3;spage=192;epage=197;aulast=Krishna
_version_ 1819202196735000576
author Gangarapu Sri Krishna
Vuppu Srinivas
K M Ayyangar
Palreddy Yadagiri Reddy
author_facet Gangarapu Sri Krishna
Vuppu Srinivas
K M Ayyangar
Palreddy Yadagiri Reddy
author_sort Gangarapu Sri Krishna
collection DOAJ
description Recently, Eclipse treatment planning system (TPS) version 8.8 was upgraded to the latest version 13.6. It is customary that the vendor gives training on how to upgrade the existing software to the new version. However, the customer is provided less inner details about changes in the new software version. According to manufacturer, accuracy of point dose calculations and irregular treatment planning is better in the new version (13.6) compared to the old version (8.8). Furthermore, the new version uses voxel-based calculations while the earlier version used point dose calculations. Major difference in intensity-modulated radiation therapy (IMRT) plans was observed between the two versions after re-optimization and re-calculations. However, minor difference was observed for IMRT cases after performing only re-calculations. It is recommended TPS quality assurance to be performed after any major upgrade of software. This can be done by performing dose calculation comparisons in TPS. To assess the difference between the versions, 25 clinical cases from the old version were compared keeping all the patient data intact including the monitor units and comparing the differences in dose calculations using dose volume histogram (DVH) analysis. Along with DVH analysis, uniformity index, conformity index, homogeneity index, and dose spillage index were also compared for both versions. The results of comparative study are presented in this paper.
first_indexed 2024-12-23T04:00:11Z
format Article
id doaj.art-cd4d7f406f254bac8cfb6afaea8ac9d2
institution Directory Open Access Journal
issn 0971-6203
1998-3913
language English
last_indexed 2024-12-23T04:00:11Z
publishDate 2016-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Journal of Medical Physics
spelling doaj.art-cd4d7f406f254bac8cfb6afaea8ac9d22022-12-21T18:00:45ZengWolters Kluwer Medknow PublicationsJournal of Medical Physics0971-62031998-39132016-01-0141319219710.4103/0971-6203.189489Comparative study of old and new versions of treatment planning system using dose volume histogram indices of clinical plansGangarapu Sri KrishnaVuppu SrinivasK M AyyangarPalreddy Yadagiri ReddyRecently, Eclipse treatment planning system (TPS) version 8.8 was upgraded to the latest version 13.6. It is customary that the vendor gives training on how to upgrade the existing software to the new version. However, the customer is provided less inner details about changes in the new software version. According to manufacturer, accuracy of point dose calculations and irregular treatment planning is better in the new version (13.6) compared to the old version (8.8). Furthermore, the new version uses voxel-based calculations while the earlier version used point dose calculations. Major difference in intensity-modulated radiation therapy (IMRT) plans was observed between the two versions after re-optimization and re-calculations. However, minor difference was observed for IMRT cases after performing only re-calculations. It is recommended TPS quality assurance to be performed after any major upgrade of software. This can be done by performing dose calculation comparisons in TPS. To assess the difference between the versions, 25 clinical cases from the old version were compared keeping all the patient data intact including the monitor units and comparing the differences in dose calculations using dose volume histogram (DVH) analysis. Along with DVH analysis, uniformity index, conformity index, homogeneity index, and dose spillage index were also compared for both versions. The results of comparative study are presented in this paper.http://www.jmp.org.in/article.asp?issn=0971-6203;year=2016;volume=41;issue=3;spage=192;epage=197;aulast=KrishnaConformity index; dose spillage index; dose volume histogram; homogeneity index; treatment planning version; uniformity index
spellingShingle Gangarapu Sri Krishna
Vuppu Srinivas
K M Ayyangar
Palreddy Yadagiri Reddy
Comparative study of old and new versions of treatment planning system using dose volume histogram indices of clinical plans
Journal of Medical Physics
Conformity index; dose spillage index; dose volume histogram; homogeneity index; treatment planning version; uniformity index
title Comparative study of old and new versions of treatment planning system using dose volume histogram indices of clinical plans
title_full Comparative study of old and new versions of treatment planning system using dose volume histogram indices of clinical plans
title_fullStr Comparative study of old and new versions of treatment planning system using dose volume histogram indices of clinical plans
title_full_unstemmed Comparative study of old and new versions of treatment planning system using dose volume histogram indices of clinical plans
title_short Comparative study of old and new versions of treatment planning system using dose volume histogram indices of clinical plans
title_sort comparative study of old and new versions of treatment planning system using dose volume histogram indices of clinical plans
topic Conformity index; dose spillage index; dose volume histogram; homogeneity index; treatment planning version; uniformity index
url http://www.jmp.org.in/article.asp?issn=0971-6203;year=2016;volume=41;issue=3;spage=192;epage=197;aulast=Krishna
work_keys_str_mv AT gangarapusrikrishna comparativestudyofoldandnewversionsoftreatmentplanningsystemusingdosevolumehistogramindicesofclinicalplans
AT vuppusrinivas comparativestudyofoldandnewversionsoftreatmentplanningsystemusingdosevolumehistogramindicesofclinicalplans
AT kmayyangar comparativestudyofoldandnewversionsoftreatmentplanningsystemusingdosevolumehistogramindicesofclinicalplans
AT palreddyyadagirireddy comparativestudyofoldandnewversionsoftreatmentplanningsystemusingdosevolumehistogramindicesofclinicalplans