The Effect of Air Parameters on the Evaporation Loss in a Natural Draft Counter-Flow Wet Cooling Tower

The measures to reduce the impact of evaporation loss in a natural draft counter-flow wet cooling tower (NDWCT) have important implications for water conservation and emissions reduction. A mathematical model of evaporation loss in the NDWCT was established by using a modified Merkel method. The NDW...

Full description

Bibliographic Details
Main Authors: Wei Yuan, Fengzhong Sun, Ruqing Liu, Xuehong Chen, Ying Li
Format: Article
Language:English
Published: MDPI AG 2020-11-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/13/23/6174
_version_ 1797546925395804160
author Wei Yuan
Fengzhong Sun
Ruqing Liu
Xuehong Chen
Ying Li
author_facet Wei Yuan
Fengzhong Sun
Ruqing Liu
Xuehong Chen
Ying Li
author_sort Wei Yuan
collection DOAJ
description The measures to reduce the impact of evaporation loss in a natural draft counter-flow wet cooling tower (NDWCT) have important implications for water conservation and emissions reduction. A mathematical model of evaporation loss in the NDWCT was established by using a modified Merkel method. The NDWCTs in the 300 MW and 600 MW power plant were taken as the research objects. Comparing experimental values with calculated values, the relative error was less than 3%. Then, the effect of air parameters on evaporation loss of NDWCT was analyzed. The results showed that, with the increase of dry bulb temperature, the evaporation heat dissipation and the evaporation loss decreased, while the rate of evaporation loss caused by unit temperature difference increased. The ambient temperature increased by 1 °C and the evaporation loss was reduced by nearly 26.65 t/h. When the relative air humidity increased, the evaporation heat dissipation and evaporation loss decreased, and the rate of evaporation loss caused by unit temperature difference decreased. When relative air humidity increased by 1%, the outlet water temperature rose by about 0.08 °C, and the evaporation loss decreased by about 5.63 t/h.
first_indexed 2024-03-10T14:36:20Z
format Article
id doaj.art-cd82fece91b7420281be1484902dafb1
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-03-10T14:36:20Z
publishDate 2020-11-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-cd82fece91b7420281be1484902dafb12023-11-20T22:09:57ZengMDPI AGEnergies1996-10732020-11-011323617410.3390/en13236174The Effect of Air Parameters on the Evaporation Loss in a Natural Draft Counter-Flow Wet Cooling TowerWei Yuan0Fengzhong Sun1Ruqing Liu2Xuehong Chen3Ying Li4School of Energy and Power Engineering, Shandong University, Jinan 250061, ChinaSchool of Energy and Power Engineering, Shandong University, Jinan 250061, ChinaSchool of Energy and Power Engineering, Shandong University, Jinan 250061, ChinaSchool of Energy and Power Engineering, Shandong University, Jinan 250061, ChinaSchool of Energy and Power Engineering, Shandong University, Jinan 250061, ChinaThe measures to reduce the impact of evaporation loss in a natural draft counter-flow wet cooling tower (NDWCT) have important implications for water conservation and emissions reduction. A mathematical model of evaporation loss in the NDWCT was established by using a modified Merkel method. The NDWCTs in the 300 MW and 600 MW power plant were taken as the research objects. Comparing experimental values with calculated values, the relative error was less than 3%. Then, the effect of air parameters on evaporation loss of NDWCT was analyzed. The results showed that, with the increase of dry bulb temperature, the evaporation heat dissipation and the evaporation loss decreased, while the rate of evaporation loss caused by unit temperature difference increased. The ambient temperature increased by 1 °C and the evaporation loss was reduced by nearly 26.65 t/h. When the relative air humidity increased, the evaporation heat dissipation and evaporation loss decreased, and the rate of evaporation loss caused by unit temperature difference decreased. When relative air humidity increased by 1%, the outlet water temperature rose by about 0.08 °C, and the evaporation loss decreased by about 5.63 t/h.https://www.mdpi.com/1996-1073/13/23/6174natural transfermathematical modelingMerkel approachevaporation lossdry bulb temperaturerelative air humidity
spellingShingle Wei Yuan
Fengzhong Sun
Ruqing Liu
Xuehong Chen
Ying Li
The Effect of Air Parameters on the Evaporation Loss in a Natural Draft Counter-Flow Wet Cooling Tower
Energies
natural transfer
mathematical modeling
Merkel approach
evaporation loss
dry bulb temperature
relative air humidity
title The Effect of Air Parameters on the Evaporation Loss in a Natural Draft Counter-Flow Wet Cooling Tower
title_full The Effect of Air Parameters on the Evaporation Loss in a Natural Draft Counter-Flow Wet Cooling Tower
title_fullStr The Effect of Air Parameters on the Evaporation Loss in a Natural Draft Counter-Flow Wet Cooling Tower
title_full_unstemmed The Effect of Air Parameters on the Evaporation Loss in a Natural Draft Counter-Flow Wet Cooling Tower
title_short The Effect of Air Parameters on the Evaporation Loss in a Natural Draft Counter-Flow Wet Cooling Tower
title_sort effect of air parameters on the evaporation loss in a natural draft counter flow wet cooling tower
topic natural transfer
mathematical modeling
Merkel approach
evaporation loss
dry bulb temperature
relative air humidity
url https://www.mdpi.com/1996-1073/13/23/6174
work_keys_str_mv AT weiyuan theeffectofairparametersontheevaporationlossinanaturaldraftcounterflowwetcoolingtower
AT fengzhongsun theeffectofairparametersontheevaporationlossinanaturaldraftcounterflowwetcoolingtower
AT ruqingliu theeffectofairparametersontheevaporationlossinanaturaldraftcounterflowwetcoolingtower
AT xuehongchen theeffectofairparametersontheevaporationlossinanaturaldraftcounterflowwetcoolingtower
AT yingli theeffectofairparametersontheevaporationlossinanaturaldraftcounterflowwetcoolingtower
AT weiyuan effectofairparametersontheevaporationlossinanaturaldraftcounterflowwetcoolingtower
AT fengzhongsun effectofairparametersontheevaporationlossinanaturaldraftcounterflowwetcoolingtower
AT ruqingliu effectofairparametersontheevaporationlossinanaturaldraftcounterflowwetcoolingtower
AT xuehongchen effectofairparametersontheevaporationlossinanaturaldraftcounterflowwetcoolingtower
AT yingli effectofairparametersontheevaporationlossinanaturaldraftcounterflowwetcoolingtower