Radiometric Cross-Calibration of Wide-Field-of-View Cameras Based on Gaofen-1/6 Satellite Synergistic Observations Using Landsat-8 Operational Land Imager Images: A Solution for Off-Nadir Wide-Field-of-View Associated Problems

The Gaofen-1 satellite is equipped with four wide-field-of-view (WFV) instruments, enabling an impressive spatial resolution of 16 m and a combined swath exceeding 800 km. These WFV images have shown their valuable applications across diverse fields. However, achieving accurate radiometric calibrati...

Full description

Bibliographic Details
Main Authors: Jiadan Dong, Yepei Chen, Xiaoling Chen, Qiangqiang Xu
Format: Article
Language:English
Published: MDPI AG 2023-08-01
Series:Remote Sensing
Subjects:
Online Access:https://www.mdpi.com/2072-4292/15/15/3851
_version_ 1797586053610078208
author Jiadan Dong
Yepei Chen
Xiaoling Chen
Qiangqiang Xu
author_facet Jiadan Dong
Yepei Chen
Xiaoling Chen
Qiangqiang Xu
author_sort Jiadan Dong
collection DOAJ
description The Gaofen-1 satellite is equipped with four wide-field-of-view (WFV) instruments, enabling an impressive spatial resolution of 16 m and a combined swath exceeding 800 km. These WFV images have shown their valuable applications across diverse fields. However, achieving accurate radiometric calibration is an essential prerequisite for establishing reliable connections between satellite signals and biophysical, as well as biochemical, parameters. However, observations with large viewing angles (>20°) pose new challenges due to the bidirectional reflectance distribution function (BRDF) effect having a pronounced impact on the accuracy of cross-radiation calibrations, especially for the off-nadir WFV1 and WFV4 cameras. To overcome this challenge, a novel approach was introduced utilizing the combined observations from the Gaofen-1 and Gaofen-6 satellites, with Landsat-8 OLI serving as a reference sensor. The key advantage of this synergistic observation strategy is the ability to obtain a greater number of image pairs that closely resemble Landsat-8 OLI reference images in terms of geometry and observation dates. This increased availability of matching images ensures a more representative dataset of the observation geometry, enabling the derived calibration coefficients to be applicable across various sun–target–sensor geometries. Then, the geometry angles and bidirectional reflectance information were put into a Particle Swarm Optimization (PSO) algorithm incorporating radiative transfer modeling. This PSO-based approach formulates cross-calibration as an optimization problem, eliminating the reliance on complex BRDF models and satellite-based BRDF products that can be affected by cloud contamination. Extensive validation experiments involving satellite data and in situ measurements demonstrated an average uncertainty of less than eight percent for the proposed cross-radiation calibration scheme. Comparisons of top-of-atmosphere (TOA) results calibrated using our proposed scheme, the previous traditional radiative transfer modeling using MODIS BRDF products for BRDF correction (RTM-BRDF) method, and official coefficients reveal the superior accuracy of our method. The proposed scheme achieves a 36.99% decrease in root mean square error (RMSE) and a 38.13% increase in mean absolute error (MAE) compared to official coefficients. Moreover, it achieves comparable accuracy to the RTM-BRDF method while eliminating the need for MODIS BRDF products, with a decrease in RMSE exceeding 14% for the off-nadir WFV1 and WFV4 cameras. The results substantiate the efficacy of the proposed scheme in enhancing cross-calibration accuracy by improving image match-up selection, efficiently removing BRDF effects, and expanding applicability to diverse observation geometries.
first_indexed 2024-03-11T00:17:50Z
format Article
id doaj.art-cd97894509ac4032bb9a994bef4fd188
institution Directory Open Access Journal
issn 2072-4292
language English
last_indexed 2024-03-11T00:17:50Z
publishDate 2023-08-01
publisher MDPI AG
record_format Article
series Remote Sensing
spelling doaj.art-cd97894509ac4032bb9a994bef4fd1882023-11-18T23:31:43ZengMDPI AGRemote Sensing2072-42922023-08-011515385110.3390/rs15153851Radiometric Cross-Calibration of Wide-Field-of-View Cameras Based on Gaofen-1/6 Satellite Synergistic Observations Using Landsat-8 Operational Land Imager Images: A Solution for Off-Nadir Wide-Field-of-View Associated ProblemsJiadan Dong0Yepei Chen1Xiaoling Chen2Qiangqiang Xu3State Key Laboratory of Information Engineering in Surveying, Mapping and Remote Sensing, Wuhan University, Wuhan 430079, ChinaSchool of Computer Science, Hubei University of Technology, Wuhan 430068, ChinaState Key Laboratory of Information Engineering in Surveying, Mapping and Remote Sensing, Wuhan University, Wuhan 430079, ChinaThe Northwest Institute of Eco-Environment and Resources (NIEER), Chinese Academy of Sciences (CAS), Lanzhou 730000, ChinaThe Gaofen-1 satellite is equipped with four wide-field-of-view (WFV) instruments, enabling an impressive spatial resolution of 16 m and a combined swath exceeding 800 km. These WFV images have shown their valuable applications across diverse fields. However, achieving accurate radiometric calibration is an essential prerequisite for establishing reliable connections between satellite signals and biophysical, as well as biochemical, parameters. However, observations with large viewing angles (>20°) pose new challenges due to the bidirectional reflectance distribution function (BRDF) effect having a pronounced impact on the accuracy of cross-radiation calibrations, especially for the off-nadir WFV1 and WFV4 cameras. To overcome this challenge, a novel approach was introduced utilizing the combined observations from the Gaofen-1 and Gaofen-6 satellites, with Landsat-8 OLI serving as a reference sensor. The key advantage of this synergistic observation strategy is the ability to obtain a greater number of image pairs that closely resemble Landsat-8 OLI reference images in terms of geometry and observation dates. This increased availability of matching images ensures a more representative dataset of the observation geometry, enabling the derived calibration coefficients to be applicable across various sun–target–sensor geometries. Then, the geometry angles and bidirectional reflectance information were put into a Particle Swarm Optimization (PSO) algorithm incorporating radiative transfer modeling. This PSO-based approach formulates cross-calibration as an optimization problem, eliminating the reliance on complex BRDF models and satellite-based BRDF products that can be affected by cloud contamination. Extensive validation experiments involving satellite data and in situ measurements demonstrated an average uncertainty of less than eight percent for the proposed cross-radiation calibration scheme. Comparisons of top-of-atmosphere (TOA) results calibrated using our proposed scheme, the previous traditional radiative transfer modeling using MODIS BRDF products for BRDF correction (RTM-BRDF) method, and official coefficients reveal the superior accuracy of our method. The proposed scheme achieves a 36.99% decrease in root mean square error (RMSE) and a 38.13% increase in mean absolute error (MAE) compared to official coefficients. Moreover, it achieves comparable accuracy to the RTM-BRDF method while eliminating the need for MODIS BRDF products, with a decrease in RMSE exceeding 14% for the off-nadir WFV1 and WFV4 cameras. The results substantiate the efficacy of the proposed scheme in enhancing cross-calibration accuracy by improving image match-up selection, efficiently removing BRDF effects, and expanding applicability to diverse observation geometries.https://www.mdpi.com/2072-4292/15/15/3851wide-field-of-viewsynergistic observationradiometric cross-calibrationbidirectional reflectance distribution function correction
spellingShingle Jiadan Dong
Yepei Chen
Xiaoling Chen
Qiangqiang Xu
Radiometric Cross-Calibration of Wide-Field-of-View Cameras Based on Gaofen-1/6 Satellite Synergistic Observations Using Landsat-8 Operational Land Imager Images: A Solution for Off-Nadir Wide-Field-of-View Associated Problems
Remote Sensing
wide-field-of-view
synergistic observation
radiometric cross-calibration
bidirectional reflectance distribution function correction
title Radiometric Cross-Calibration of Wide-Field-of-View Cameras Based on Gaofen-1/6 Satellite Synergistic Observations Using Landsat-8 Operational Land Imager Images: A Solution for Off-Nadir Wide-Field-of-View Associated Problems
title_full Radiometric Cross-Calibration of Wide-Field-of-View Cameras Based on Gaofen-1/6 Satellite Synergistic Observations Using Landsat-8 Operational Land Imager Images: A Solution for Off-Nadir Wide-Field-of-View Associated Problems
title_fullStr Radiometric Cross-Calibration of Wide-Field-of-View Cameras Based on Gaofen-1/6 Satellite Synergistic Observations Using Landsat-8 Operational Land Imager Images: A Solution for Off-Nadir Wide-Field-of-View Associated Problems
title_full_unstemmed Radiometric Cross-Calibration of Wide-Field-of-View Cameras Based on Gaofen-1/6 Satellite Synergistic Observations Using Landsat-8 Operational Land Imager Images: A Solution for Off-Nadir Wide-Field-of-View Associated Problems
title_short Radiometric Cross-Calibration of Wide-Field-of-View Cameras Based on Gaofen-1/6 Satellite Synergistic Observations Using Landsat-8 Operational Land Imager Images: A Solution for Off-Nadir Wide-Field-of-View Associated Problems
title_sort radiometric cross calibration of wide field of view cameras based on gaofen 1 6 satellite synergistic observations using landsat 8 operational land imager images a solution for off nadir wide field of view associated problems
topic wide-field-of-view
synergistic observation
radiometric cross-calibration
bidirectional reflectance distribution function correction
url https://www.mdpi.com/2072-4292/15/15/3851
work_keys_str_mv AT jiadandong radiometriccrosscalibrationofwidefieldofviewcamerasbasedongaofen16satellitesynergisticobservationsusinglandsat8operationallandimagerimagesasolutionforoffnadirwidefieldofviewassociatedproblems
AT yepeichen radiometriccrosscalibrationofwidefieldofviewcamerasbasedongaofen16satellitesynergisticobservationsusinglandsat8operationallandimagerimagesasolutionforoffnadirwidefieldofviewassociatedproblems
AT xiaolingchen radiometriccrosscalibrationofwidefieldofviewcamerasbasedongaofen16satellitesynergisticobservationsusinglandsat8operationallandimagerimagesasolutionforoffnadirwidefieldofviewassociatedproblems
AT qiangqiangxu radiometriccrosscalibrationofwidefieldofviewcamerasbasedongaofen16satellitesynergisticobservationsusinglandsat8operationallandimagerimagesasolutionforoffnadirwidefieldofviewassociatedproblems