Comparison of Two Techniques of Measuring Activated Clotting Time During Cardiac Surgery
Objective: To compare two techniques of activated clotting time (ACT) measurement by two different devices to evaluate the correlation and agreement between these techniques at different points of time during cardiac surgery. Study Design: Comparative Cross-sectional Study. Study settings: Ca...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Army Medical College Rawalpindi
2022-11-01
|
Series: | Pakistan Armed Forces Medical Journal |
Subjects: | |
Online Access: | https://pafmj.org/index.php/PAFMJ/article/view/9550 |
_version_ | 1828048824099143680 |
---|---|
author | Waqas Alam Syed Aqeel Hussain Muhammad Ali Muhammad Adnan Akram Muhammad Umar Farooq Rehan Masroor Hafsa Khalil Ayesha Sana |
author_facet | Waqas Alam Syed Aqeel Hussain Muhammad Ali Muhammad Adnan Akram Muhammad Umar Farooq Rehan Masroor Hafsa Khalil Ayesha Sana |
author_sort | Waqas Alam |
collection | DOAJ |
description |
Objective: To compare two techniques of activated clotting time (ACT) measurement by two different devices to evaluate the correlation and agreement between these techniques at different points of time during cardiac surgery.
Study Design: Comparative Cross-sectional Study.
Study settings: Cardiac Anesthesia Department, Armed Forces Institute of Cardiology and National Institute of Heart Diseases, Rawalpindi Pakistan, from Feb 2022 to Apr 2022.
Methodology: 100 patients undergoing CABG surgery on pump were included by non-probability consecutive sampling technique. Two devices operating on different techniques of measurement were used to measure ACT at four different points of time during surgery. Same sample was used to measure ACT from both devices. Data was collected and analysed by SPSS V.20.0. Pearson's chi square test and paired sample t-test were applied to measure the significance. Linear regression analysis was done to find correlation and Bland Altman plot was used for checking agreement between ACT values from both devices.p-value less than 0.05 was considered significant.
Results: Out of 100, male patients were 79 and female patients were 21. Their mean age was 54.18±11.91 years and mean weight was 79.06±18.49 kg. Moderate positive correlation was found with Pearson r value of 0.55. There was poor agreement between the ACTs measured by two devices. On average Hem R measures ACT 63.54±50.83 seconds higher than Hem JSP. Average mean and median values for Hem R group are 400.03±59.39 sec and 397.75sec respectively and for Hem JSP group are 336.49±44.63 sec and 340.5 sec respectively.
Conclusion: There is moderate positive correlation but poor agreement between the values of ACT measured by Hem R and
Hem JSP due to different techniques of measurement so these should not be used interchangeably.
|
first_indexed | 2024-04-10T19:01:38Z |
format | Article |
id | doaj.art-cdaa09a58e4746489caf4b6488c9b6fc |
institution | Directory Open Access Journal |
issn | 0030-9648 2411-8842 |
language | English |
last_indexed | 2024-04-10T19:01:38Z |
publishDate | 2022-11-01 |
publisher | Army Medical College Rawalpindi |
record_format | Article |
series | Pakistan Armed Forces Medical Journal |
spelling | doaj.art-cdaa09a58e4746489caf4b6488c9b6fc2023-01-31T08:22:58ZengArmy Medical College RawalpindiPakistan Armed Forces Medical Journal0030-96482411-88422022-11-0172SUPPL-310.51253/pafmj.v72iSUPPL-3.9550Comparison of Two Techniques of Measuring Activated Clotting Time During Cardiac SurgeryWaqas Alam0Syed Aqeel Hussain1Muhammad Ali2Muhammad Adnan Akram3Muhammad Umar Farooq4Rehan Masroor5Hafsa Khalil6Ayesha Sana7Armed Forces Institute of Cardiology/National Institute of Heart Diseases (AFIC/NIHD)/National University of Medical Sciences (NUMS) Rawalpindi, PakistanArmed Forces Institute of Cardiology/National Institute of Heart Diseases (AFIC/NIHD)/National University of Medical Sciences (NUMS) Rawalpindi, PakistanArmed Forces Institute of Cardiology/National Institute of Heart Diseases (AFIC/NIHD)/National University of Medical Sciences (NUMS) Rawalpindi, PakistanArmed Forces Institute of Cardiology/National Institute of Heart Diseases (AFIC/NIHD)/National University of Medical Sciences (NUMS) Rawalpindi, PakistanArmed Forces Institute of Cardiology/National Institute of Heart Diseases (AFIC/NIHD)/National University of Medical Sciences (NUMS) Rawalpindi, PakistanArmed Forces Institute of Cardiology/National Institute of Heart Diseases (AFIC/NIHD)/National University of Medical Sciences (NUMS) Rawalpindi, PakistanArmed Forces Institute of Cardiology/National Institute of Heart Diseases (AFIC/NIHD)/National University of Medical Sciences (NUMS) Rawalpindi, PakistanArmed Forces Institute of Cardiology/National Institute of Heart Diseases (AFIC/NIHD)/National University of Medical Sciences (NUMS) Rawalpindi, Pakistan Objective: To compare two techniques of activated clotting time (ACT) measurement by two different devices to evaluate the correlation and agreement between these techniques at different points of time during cardiac surgery. Study Design: Comparative Cross-sectional Study. Study settings: Cardiac Anesthesia Department, Armed Forces Institute of Cardiology and National Institute of Heart Diseases, Rawalpindi Pakistan, from Feb 2022 to Apr 2022. Methodology: 100 patients undergoing CABG surgery on pump were included by non-probability consecutive sampling technique. Two devices operating on different techniques of measurement were used to measure ACT at four different points of time during surgery. Same sample was used to measure ACT from both devices. Data was collected and analysed by SPSS V.20.0. Pearson's chi square test and paired sample t-test were applied to measure the significance. Linear regression analysis was done to find correlation and Bland Altman plot was used for checking agreement between ACT values from both devices.p-value less than 0.05 was considered significant. Results: Out of 100, male patients were 79 and female patients were 21. Their mean age was 54.18±11.91 years and mean weight was 79.06±18.49 kg. Moderate positive correlation was found with Pearson r value of 0.55. There was poor agreement between the ACTs measured by two devices. On average Hem R measures ACT 63.54±50.83 seconds higher than Hem JSP. Average mean and median values for Hem R group are 400.03±59.39 sec and 397.75sec respectively and for Hem JSP group are 336.49±44.63 sec and 340.5 sec respectively. Conclusion: There is moderate positive correlation but poor agreement between the values of ACT measured by Hem R and Hem JSP due to different techniques of measurement so these should not be used interchangeably. https://pafmj.org/index.php/PAFMJ/article/view/9550Activated clotting timeCABGCardiac surgeryHemochronHeparin |
spellingShingle | Waqas Alam Syed Aqeel Hussain Muhammad Ali Muhammad Adnan Akram Muhammad Umar Farooq Rehan Masroor Hafsa Khalil Ayesha Sana Comparison of Two Techniques of Measuring Activated Clotting Time During Cardiac Surgery Pakistan Armed Forces Medical Journal Activated clotting time CABG Cardiac surgery Hemochron Heparin |
title | Comparison of Two Techniques of Measuring Activated Clotting Time During Cardiac Surgery |
title_full | Comparison of Two Techniques of Measuring Activated Clotting Time During Cardiac Surgery |
title_fullStr | Comparison of Two Techniques of Measuring Activated Clotting Time During Cardiac Surgery |
title_full_unstemmed | Comparison of Two Techniques of Measuring Activated Clotting Time During Cardiac Surgery |
title_short | Comparison of Two Techniques of Measuring Activated Clotting Time During Cardiac Surgery |
title_sort | comparison of two techniques of measuring activated clotting time during cardiac surgery |
topic | Activated clotting time CABG Cardiac surgery Hemochron Heparin |
url | https://pafmj.org/index.php/PAFMJ/article/view/9550 |
work_keys_str_mv | AT waqasalam comparisonoftwotechniquesofmeasuringactivatedclottingtimeduringcardiacsurgery AT syedaqeelhussain comparisonoftwotechniquesofmeasuringactivatedclottingtimeduringcardiacsurgery AT muhammadali comparisonoftwotechniquesofmeasuringactivatedclottingtimeduringcardiacsurgery AT muhammadadnanakram comparisonoftwotechniquesofmeasuringactivatedclottingtimeduringcardiacsurgery AT muhammadumarfarooq comparisonoftwotechniquesofmeasuringactivatedclottingtimeduringcardiacsurgery AT rehanmasroor comparisonoftwotechniquesofmeasuringactivatedclottingtimeduringcardiacsurgery AT hafsakhalil comparisonoftwotechniquesofmeasuringactivatedclottingtimeduringcardiacsurgery AT ayeshasana comparisonoftwotechniquesofmeasuringactivatedclottingtimeduringcardiacsurgery |