Development of a Contact Glass-Break Detector for the Highest Security Level
The main object of this research was to develop a security system to evaluate the intrusion into an object through a glass pane. More specifically, this study deals with sensing and evaluating signals from a contact glass-break detector, which is part of an intruder alarm system. Each alarm detector...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2023-12-01
|
Series: | Sensors |
Subjects: | |
Online Access: | https://www.mdpi.com/1424-8220/24/1/97 |
_version_ | 1827384502959210496 |
---|---|
author | Vaclav Mach Ales Mizera Pavel Stoklasek Michaela Karhankova Milan Adamek Martin Bednarik |
author_facet | Vaclav Mach Ales Mizera Pavel Stoklasek Michaela Karhankova Milan Adamek Martin Bednarik |
author_sort | Vaclav Mach |
collection | DOAJ |
description | The main object of this research was to develop a security system to evaluate the intrusion into an object through a glass pane. More specifically, this study deals with sensing and evaluating signals from a contact glass-break detector, which is part of an intruder alarm system. Each alarm detector in an alarm system must accomplish certain security level requirements that strictly describe the requirements for the area of use and the detector’s reliability. To date, no contact glass-break detector has been developed and fully tested to meet the stringent requirements of the highest security level. A contact glass-break detector was developed whose main part is an accelerometer that transmits signals from the glass pane. These signals were evaluated according to the developed methodology. It was verified that the proposed system can distinguish at the highest security level between false alarms and situations where the building has been intruded. |
first_indexed | 2024-03-08T14:57:44Z |
format | Article |
id | doaj.art-cde1ad2a9b9543959cc91b200b37e643 |
institution | Directory Open Access Journal |
issn | 1424-8220 |
language | English |
last_indexed | 2024-03-08T14:57:44Z |
publishDate | 2023-12-01 |
publisher | MDPI AG |
record_format | Article |
series | Sensors |
spelling | doaj.art-cde1ad2a9b9543959cc91b200b37e6432024-01-10T15:08:33ZengMDPI AGSensors1424-82202023-12-012419710.3390/s24010097Development of a Contact Glass-Break Detector for the Highest Security LevelVaclav Mach0Ales Mizera1Pavel Stoklasek2Michaela Karhankova3Milan Adamek4Martin Bednarik5Faculty of Applied Informatics, Tomas Bata University in Zlin, Nad Stranemi 4511, 760 05 Zlin, Czech RepublicFaculty of Applied Informatics, Tomas Bata University in Zlin, Nad Stranemi 4511, 760 05 Zlin, Czech RepublicFaculty of Applied Informatics, Tomas Bata University in Zlin, Nad Stranemi 4511, 760 05 Zlin, Czech RepublicFaculty of Applied Informatics, Tomas Bata University in Zlin, Nad Stranemi 4511, 760 05 Zlin, Czech RepublicFaculty of Applied Informatics, Tomas Bata University in Zlin, Nad Stranemi 4511, 760 05 Zlin, Czech RepublicFaculty of Technology, Tomas Bata University in Zlin, Vavreckova 5669, 760 01 Zlin, Czech RepublicThe main object of this research was to develop a security system to evaluate the intrusion into an object through a glass pane. More specifically, this study deals with sensing and evaluating signals from a contact glass-break detector, which is part of an intruder alarm system. Each alarm detector in an alarm system must accomplish certain security level requirements that strictly describe the requirements for the area of use and the detector’s reliability. To date, no contact glass-break detector has been developed and fully tested to meet the stringent requirements of the highest security level. A contact glass-break detector was developed whose main part is an accelerometer that transmits signals from the glass pane. These signals were evaluated according to the developed methodology. It was verified that the proposed system can distinguish at the highest security level between false alarms and situations where the building has been intruded.https://www.mdpi.com/1424-8220/24/1/97glass breakdetectoraccelerometeralarm systemsurveillance |
spellingShingle | Vaclav Mach Ales Mizera Pavel Stoklasek Michaela Karhankova Milan Adamek Martin Bednarik Development of a Contact Glass-Break Detector for the Highest Security Level Sensors glass break detector accelerometer alarm system surveillance |
title | Development of a Contact Glass-Break Detector for the Highest Security Level |
title_full | Development of a Contact Glass-Break Detector for the Highest Security Level |
title_fullStr | Development of a Contact Glass-Break Detector for the Highest Security Level |
title_full_unstemmed | Development of a Contact Glass-Break Detector for the Highest Security Level |
title_short | Development of a Contact Glass-Break Detector for the Highest Security Level |
title_sort | development of a contact glass break detector for the highest security level |
topic | glass break detector accelerometer alarm system surveillance |
url | https://www.mdpi.com/1424-8220/24/1/97 |
work_keys_str_mv | AT vaclavmach developmentofacontactglassbreakdetectorforthehighestsecuritylevel AT alesmizera developmentofacontactglassbreakdetectorforthehighestsecuritylevel AT pavelstoklasek developmentofacontactglassbreakdetectorforthehighestsecuritylevel AT michaelakarhankova developmentofacontactglassbreakdetectorforthehighestsecuritylevel AT milanadamek developmentofacontactglassbreakdetectorforthehighestsecuritylevel AT martinbednarik developmentofacontactglassbreakdetectorforthehighestsecuritylevel |