COMPARISON BETWEEN DECISION TREE AND OPTIMAL POWER FLOW TECHNIQUES APPLIED TO VOLTAGE CORRECTIVE CONTROL IN ELECTRIC SYSTEMS

This article presents a comparison of using techniques of optimal load flow and decision tree in making corrective voltage control actions for electrical power systems under insecure operation condition, that is, with voltage constraints violated. The decision tree technique is used in conjunction w...

Full description

Bibliographic Details
Main Authors: Joabe Chaves Nogueira, Benedito da Graças Duarte Rodrigues, Amanda Thais dos Reis Fernandes, Werbeston Douglas de Oliveira, Ubiratan Holanda Bezerra
Format: Article
Language:English
Published: Institute of Technology and Education Galileo da Amazônia 2020-02-01
Series:ITEGAM-JETIA
Online Access:https://itegam-jetia.org/journal/index.php/jetia/article/view/617
_version_ 1828235407602483200
author Joabe Chaves Nogueira
Benedito da Graças Duarte Rodrigues
Amanda Thais dos Reis Fernandes
Werbeston Douglas de Oliveira
Ubiratan Holanda Bezerra
author_facet Joabe Chaves Nogueira
Benedito da Graças Duarte Rodrigues
Amanda Thais dos Reis Fernandes
Werbeston Douglas de Oliveira
Ubiratan Holanda Bezerra
author_sort Joabe Chaves Nogueira
collection DOAJ
description This article presents a comparison of using techniques of optimal load flow and decision tree in making corrective voltage control actions for electrical power systems under insecure operation condition, that is, with voltage constraints violated. The decision tree technique is used in conjunction with a technique of sensitivity analysis in such a way that control actions are taken to be more effective to eliminate the voltage constraints violation in each case of contingency analyzed. A comparison is made between the control actions suggested by the optimal load flow strategy and those suggested by the decision tree for the same operating condition, discussing the achievement of implementing these actions in a real power system. The analysis methodology proposed here is tested in a real power system of a Brazilian utility, which operates in the State of Amapá - Brazil. The results showed how both methodologies can be used as operational tools in power system supervision and control centers.
first_indexed 2024-04-12T20:14:12Z
format Article
id doaj.art-ce4bb5f933e44f5bb84cea67a554b444
institution Directory Open Access Journal
issn 2447-0228
language English
last_indexed 2024-04-12T20:14:12Z
publishDate 2020-02-01
publisher Institute of Technology and Education Galileo da Amazônia
record_format Article
series ITEGAM-JETIA
spelling doaj.art-ce4bb5f933e44f5bb84cea67a554b4442022-12-22T03:18:10ZengInstitute of Technology and Education Galileo da AmazôniaITEGAM-JETIA2447-02282020-02-01621COMPARISON BETWEEN DECISION TREE AND OPTIMAL POWER FLOW TECHNIQUES APPLIED TO VOLTAGE CORRECTIVE CONTROL IN ELECTRIC SYSTEMSJoabe Chaves NogueiraBenedito da Graças Duarte RodriguesAmanda Thais dos Reis FernandesWerbeston Douglas de OliveiraUbiratan Holanda BezerraThis article presents a comparison of using techniques of optimal load flow and decision tree in making corrective voltage control actions for electrical power systems under insecure operation condition, that is, with voltage constraints violated. The decision tree technique is used in conjunction with a technique of sensitivity analysis in such a way that control actions are taken to be more effective to eliminate the voltage constraints violation in each case of contingency analyzed. A comparison is made between the control actions suggested by the optimal load flow strategy and those suggested by the decision tree for the same operating condition, discussing the achievement of implementing these actions in a real power system. The analysis methodology proposed here is tested in a real power system of a Brazilian utility, which operates in the State of Amapá - Brazil. The results showed how both methodologies can be used as operational tools in power system supervision and control centers.https://itegam-jetia.org/journal/index.php/jetia/article/view/617
spellingShingle Joabe Chaves Nogueira
Benedito da Graças Duarte Rodrigues
Amanda Thais dos Reis Fernandes
Werbeston Douglas de Oliveira
Ubiratan Holanda Bezerra
COMPARISON BETWEEN DECISION TREE AND OPTIMAL POWER FLOW TECHNIQUES APPLIED TO VOLTAGE CORRECTIVE CONTROL IN ELECTRIC SYSTEMS
ITEGAM-JETIA
title COMPARISON BETWEEN DECISION TREE AND OPTIMAL POWER FLOW TECHNIQUES APPLIED TO VOLTAGE CORRECTIVE CONTROL IN ELECTRIC SYSTEMS
title_full COMPARISON BETWEEN DECISION TREE AND OPTIMAL POWER FLOW TECHNIQUES APPLIED TO VOLTAGE CORRECTIVE CONTROL IN ELECTRIC SYSTEMS
title_fullStr COMPARISON BETWEEN DECISION TREE AND OPTIMAL POWER FLOW TECHNIQUES APPLIED TO VOLTAGE CORRECTIVE CONTROL IN ELECTRIC SYSTEMS
title_full_unstemmed COMPARISON BETWEEN DECISION TREE AND OPTIMAL POWER FLOW TECHNIQUES APPLIED TO VOLTAGE CORRECTIVE CONTROL IN ELECTRIC SYSTEMS
title_short COMPARISON BETWEEN DECISION TREE AND OPTIMAL POWER FLOW TECHNIQUES APPLIED TO VOLTAGE CORRECTIVE CONTROL IN ELECTRIC SYSTEMS
title_sort comparison between decision tree and optimal power flow techniques applied to voltage corrective control in electric systems
url https://itegam-jetia.org/journal/index.php/jetia/article/view/617
work_keys_str_mv AT joabechavesnogueira comparisonbetweendecisiontreeandoptimalpowerflowtechniquesappliedtovoltagecorrectivecontrolinelectricsystems
AT beneditodagracasduarterodrigues comparisonbetweendecisiontreeandoptimalpowerflowtechniquesappliedtovoltagecorrectivecontrolinelectricsystems
AT amandathaisdosreisfernandes comparisonbetweendecisiontreeandoptimalpowerflowtechniquesappliedtovoltagecorrectivecontrolinelectricsystems
AT werbestondouglasdeoliveira comparisonbetweendecisiontreeandoptimalpowerflowtechniquesappliedtovoltagecorrectivecontrolinelectricsystems
AT ubiratanholandabezerra comparisonbetweendecisiontreeandoptimalpowerflowtechniquesappliedtovoltagecorrectivecontrolinelectricsystems