Stress distribution analysis on the one-stage non-submerged and two-stage submerged system implant supported bridge

Introduction: Tooth restoration and implant-supported was one of the methods to overcome the free end cases. Abutment and implant are two components that are fused together by a screw. Therefore, the main problem to solve are loosened screw and implant or abutment fracture because of increasing unpr...

Full description

Bibliographic Details
Main Authors: Joko Prihatono, Taufik Sumarsongko, Tata Cipta Dirgantara, Rasmi Rikmasari
Format: Article
Language:English
Published: Universitas Padjadjaran 2018-03-01
Series:Padjadjaran Journal of Dentistry
Subjects:
Online Access:http://jurnal.unpad.ac.id/pjd/article/view/16233
_version_ 1819242950180208640
author Joko Prihatono
Taufik Sumarsongko
Tata Cipta Dirgantara
Rasmi Rikmasari
author_facet Joko Prihatono
Taufik Sumarsongko
Tata Cipta Dirgantara
Rasmi Rikmasari
author_sort Joko Prihatono
collection DOAJ
description Introduction: Tooth restoration and implant-supported was one of the methods to overcome the free end cases. Abutment and implant are two components that are fused together by a screw. Therefore, the main problem to solve are loosened screw and implant or abutment fracture because of increasing unpredictable potential force on the implant, abutment, and screw. The purpose of this research was to describe the distribution stress between the connection of the body of implant and abutment on the submerged and non-submerged design of the implant supported bridge. Method: The submerged and non-submerged design implant have been analyzed using the Finite Element Method under lateral and vertical static load for 180 N. The numeric model for lower jaw posterior segmented bone was determined by computed tomography, and the load measurement was performed to observe the distribution at the connection between the body of implant and the abutment of the implant supported bridge submerge and non-submerged design. Results: At the lateral load, the distribution strength value was 1.562x107 Pa, whilst for the non-submerged was 9.63x107Pa. At the vertical load, the distribution strength value was 1.038x107 Pa, whilst for the non-submerged was 3.342x107Pa. At the load of 180 N towards the vertical and lateral on the supported implant bridge, the distribution strength value had a smaller scale compared to the ultimate tensile strength (UTS), which was 1040 MPa (1.04 x 109 Pa). Conclusion: Both of the design including the secondary component (abutment) was safe to used as the supporting implant bridge.
first_indexed 2024-12-23T14:47:56Z
format Article
id doaj.art-ce74cabdb6a34f5e9a445d59be2a03b8
institution Directory Open Access Journal
issn 1979-0201
2549-6212
language English
last_indexed 2024-12-23T14:47:56Z
publishDate 2018-03-01
publisher Universitas Padjadjaran
record_format Article
series Padjadjaran Journal of Dentistry
spelling doaj.art-ce74cabdb6a34f5e9a445d59be2a03b82022-12-21T17:43:03ZengUniversitas PadjadjaranPadjadjaran Journal of Dentistry1979-02012549-62122018-03-01301657210.24198/pjd.vol30no1.162338729Stress distribution analysis on the one-stage non-submerged and two-stage submerged system implant supported bridgeJoko Prihatono0Taufik Sumarsongko1Tata Cipta Dirgantara2Rasmi Rikmasari3Pertamina Jaya HospitalDepartement of ProsthodonticBandung Institute of TechnologyUniversitas PadjadjaranIntroduction: Tooth restoration and implant-supported was one of the methods to overcome the free end cases. Abutment and implant are two components that are fused together by a screw. Therefore, the main problem to solve are loosened screw and implant or abutment fracture because of increasing unpredictable potential force on the implant, abutment, and screw. The purpose of this research was to describe the distribution stress between the connection of the body of implant and abutment on the submerged and non-submerged design of the implant supported bridge. Method: The submerged and non-submerged design implant have been analyzed using the Finite Element Method under lateral and vertical static load for 180 N. The numeric model for lower jaw posterior segmented bone was determined by computed tomography, and the load measurement was performed to observe the distribution at the connection between the body of implant and the abutment of the implant supported bridge submerge and non-submerged design. Results: At the lateral load, the distribution strength value was 1.562x107 Pa, whilst for the non-submerged was 9.63x107Pa. At the vertical load, the distribution strength value was 1.038x107 Pa, whilst for the non-submerged was 3.342x107Pa. At the load of 180 N towards the vertical and lateral on the supported implant bridge, the distribution strength value had a smaller scale compared to the ultimate tensile strength (UTS), which was 1040 MPa (1.04 x 109 Pa). Conclusion: Both of the design including the secondary component (abutment) was safe to used as the supporting implant bridge.http://jurnal.unpad.ac.id/pjd/article/view/16233distribution strength, mastication load, submerged and non-submerged implant design.
spellingShingle Joko Prihatono
Taufik Sumarsongko
Tata Cipta Dirgantara
Rasmi Rikmasari
Stress distribution analysis on the one-stage non-submerged and two-stage submerged system implant supported bridge
Padjadjaran Journal of Dentistry
distribution strength, mastication load, submerged and non-submerged implant design.
title Stress distribution analysis on the one-stage non-submerged and two-stage submerged system implant supported bridge
title_full Stress distribution analysis on the one-stage non-submerged and two-stage submerged system implant supported bridge
title_fullStr Stress distribution analysis on the one-stage non-submerged and two-stage submerged system implant supported bridge
title_full_unstemmed Stress distribution analysis on the one-stage non-submerged and two-stage submerged system implant supported bridge
title_short Stress distribution analysis on the one-stage non-submerged and two-stage submerged system implant supported bridge
title_sort stress distribution analysis on the one stage non submerged and two stage submerged system implant supported bridge
topic distribution strength, mastication load, submerged and non-submerged implant design.
url http://jurnal.unpad.ac.id/pjd/article/view/16233
work_keys_str_mv AT jokoprihatono stressdistributionanalysisontheonestagenonsubmergedandtwostagesubmergedsystemimplantsupportedbridge
AT taufiksumarsongko stressdistributionanalysisontheonestagenonsubmergedandtwostagesubmergedsystemimplantsupportedbridge
AT tataciptadirgantara stressdistributionanalysisontheonestagenonsubmergedandtwostagesubmergedsystemimplantsupportedbridge
AT rasmirikmasari stressdistributionanalysisontheonestagenonsubmergedandtwostagesubmergedsystemimplantsupportedbridge