EXPERIMENTAL CHECK OF EFFECTIVE MANAGEMENT OF LINKS OF GAS AND SMOKE PROTECTIVE SERVICE AT INTRODUCTION OF SENSORS OF A MOTIONLESS STATE

Objectives The environmental factors at the fire that affect the efficiency of the operational activities of fire and rescue units in an unfit environment for breathing and statistical information on the functioning of the gas and smoke protection service in regions of the Russian Federation are giv...

Full description

Bibliographic Details
Main Author: E. N. Tuzhikov
Format: Article
Language:Russian
Published: Dagestan State Technical University 2019-06-01
Series:Вестник Дагестанского государственного технического университета: Технические науки
Subjects:
Online Access:https://vestnik.dgtu.ru/jour/article/view/628
_version_ 1797702388678656000
author E. N. Tuzhikov
author_facet E. N. Tuzhikov
author_sort E. N. Tuzhikov
collection DOAJ
description Objectives The environmental factors at the fire that affect the efficiency of the operational activities of fire and rescue units in an unfit environment for breathing and statistical information on the functioning of the gas and smoke protection service in regions of the Russian Federation are given. Method The methodology for conducting experiments with groups of reconnaissance to search for an injured firefighter is given. A description of the location of the experiment and the algorithm for the movement of reconnaissance groups are presented. Result Results of experiments on the actions of the units of gas and smoke protective service inside fire object on search of the injured firefighter who is in unconsciousness are given. The experiment was conducted in the conditions of premises without lighting and with influence of noise hindrances to staff of groups of reconnaissance. The results of the experiments confirm the need of identification of firefighters at the site of a fire by of sensors of a motionless state and light reflecting elements of clothes and equipment. The results of the experiments are correlated with previously conducted experiments to study the time of fire reconnaissance in the premises of residential and public buildings. The necessity of the research of the parameters of the work of groups of reconnaissance at various sites on the basis of the temporal parameters of the work of gas and smoke defenders has been determined. Conclusion The positive influence of the presence factor of immobile sensors in the personnel of fire and rescue units operating in conditions unsuitable for breathing environment has been established. The proposed directions for the research of organizational systems for the management of fire departments at the fire.
first_indexed 2024-03-12T04:50:16Z
format Article
id doaj.art-cedcfacab0bc43a1a3c33a2fa93e6bc1
institution Directory Open Access Journal
issn 2073-6185
2542-095X
language Russian
last_indexed 2024-03-12T04:50:16Z
publishDate 2019-06-01
publisher Dagestan State Technical University
record_format Article
series Вестник Дагестанского государственного технического университета: Технические науки
spelling doaj.art-cedcfacab0bc43a1a3c33a2fa93e6bc12023-09-03T09:26:26ZrusDagestan State Technical UniversityВестник Дагестанского государственного технического университета: Технические науки2073-61852542-095X2019-06-014541213210.21822/2073-6185-2018-45-4-124-132477EXPERIMENTAL CHECK OF EFFECTIVE MANAGEMENT OF LINKS OF GAS AND SMOKE PROTECTIVE SERVICE AT INTRODUCTION OF SENSORS OF A MOTIONLESS STATEE. N. Tuzhikov0Уральский институт государственной противопожарной службы МЧС РоссииObjectives The environmental factors at the fire that affect the efficiency of the operational activities of fire and rescue units in an unfit environment for breathing and statistical information on the functioning of the gas and smoke protection service in regions of the Russian Federation are given. Method The methodology for conducting experiments with groups of reconnaissance to search for an injured firefighter is given. A description of the location of the experiment and the algorithm for the movement of reconnaissance groups are presented. Result Results of experiments on the actions of the units of gas and smoke protective service inside fire object on search of the injured firefighter who is in unconsciousness are given. The experiment was conducted in the conditions of premises without lighting and with influence of noise hindrances to staff of groups of reconnaissance. The results of the experiments confirm the need of identification of firefighters at the site of a fire by of sensors of a motionless state and light reflecting elements of clothes and equipment. The results of the experiments are correlated with previously conducted experiments to study the time of fire reconnaissance in the premises of residential and public buildings. The necessity of the research of the parameters of the work of groups of reconnaissance at various sites on the basis of the temporal parameters of the work of gas and smoke defenders has been determined. Conclusion The positive influence of the presence factor of immobile sensors in the personnel of fire and rescue units operating in conditions unsuitable for breathing environment has been established. The proposed directions for the research of organizational systems for the management of fire departments at the fire.https://vestnik.dgtu.ru/jour/article/view/628пожаротушениегазодымозащитная службаопасные факторы пожарадатчик неподвижного состоянияпожарныйпострадавший
spellingShingle E. N. Tuzhikov
EXPERIMENTAL CHECK OF EFFECTIVE MANAGEMENT OF LINKS OF GAS AND SMOKE PROTECTIVE SERVICE AT INTRODUCTION OF SENSORS OF A MOTIONLESS STATE
Вестник Дагестанского государственного технического университета: Технические науки
пожаротушение
газодымозащитная служба
опасные факторы пожара
датчик неподвижного состояния
пожарный
пострадавший
title EXPERIMENTAL CHECK OF EFFECTIVE MANAGEMENT OF LINKS OF GAS AND SMOKE PROTECTIVE SERVICE AT INTRODUCTION OF SENSORS OF A MOTIONLESS STATE
title_full EXPERIMENTAL CHECK OF EFFECTIVE MANAGEMENT OF LINKS OF GAS AND SMOKE PROTECTIVE SERVICE AT INTRODUCTION OF SENSORS OF A MOTIONLESS STATE
title_fullStr EXPERIMENTAL CHECK OF EFFECTIVE MANAGEMENT OF LINKS OF GAS AND SMOKE PROTECTIVE SERVICE AT INTRODUCTION OF SENSORS OF A MOTIONLESS STATE
title_full_unstemmed EXPERIMENTAL CHECK OF EFFECTIVE MANAGEMENT OF LINKS OF GAS AND SMOKE PROTECTIVE SERVICE AT INTRODUCTION OF SENSORS OF A MOTIONLESS STATE
title_short EXPERIMENTAL CHECK OF EFFECTIVE MANAGEMENT OF LINKS OF GAS AND SMOKE PROTECTIVE SERVICE AT INTRODUCTION OF SENSORS OF A MOTIONLESS STATE
title_sort experimental check of effective management of links of gas and smoke protective service at introduction of sensors of a motionless state
topic пожаротушение
газодымозащитная служба
опасные факторы пожара
датчик неподвижного состояния
пожарный
пострадавший
url https://vestnik.dgtu.ru/jour/article/view/628
work_keys_str_mv AT entuzhikov experimentalcheckofeffectivemanagementoflinksofgasandsmokeprotectiveserviceatintroductionofsensorsofamotionlessstate