GAS TURBINE UNITE INLET AIR COOLING BY USING AN EXCESSIVE REFRIGERATION CAPACITY OF ABSORPTION CHILLER IN BUSTER AIR COOLER

The processes of gas turbine unit inlet air cooling by absorption lithium-bromide chiller utilizing the turbine exhaust gas waste heat as athermotransformer has been analyzed for hour-by-hour changing ambient air temperatures and changeable heat loads on the air cooler as consequence. The computer p...

Full description

Bibliographic Details
Main Authors: Андрій Миколайович Радченко, Роман Миколайович Радченко, Сергій Анатолійович Кантор, Богдан Сергійович Портной, Веніамін Сергійович Ткаченко
Format: Article
Language:English
Published: National Aerospace University «Kharkiv Aviation Institute» 2018-02-01
Series:Авіаційно-космічна техніка та технологія
Subjects:
Online Access:http://nti.khai.edu/ojs/index.php/aktt/article/view/31
_version_ 1797714259532054528
author Андрій Миколайович Радченко
Роман Миколайович Радченко
Сергій Анатолійович Кантор
Богдан Сергійович Портной
Веніамін Сергійович Ткаченко
author_facet Андрій Миколайович Радченко
Роман Миколайович Радченко
Сергій Анатолійович Кантор
Богдан Сергійович Портной
Веніамін Сергійович Ткаченко
author_sort Андрій Миколайович Радченко
collection DOAJ
description The processes of gas turbine unit inlet air cooling by absorption lithium-bromide chiller utilizing the turbine exhaust gas waste heat as athermotransformer has been analyzed for hour-by-hour changing ambient air temperatures and changeable heat loads on the air cooler as consequence. The computer programs of the firms-producers of heat exchangers were used for gas turbine unit inlet air cooling processes simulation. It is shown that at decreased heat loads on the air cooler an excessive refrigeration capacity of the absorption lithium-bromidechiller exceeding current heat loads is generated which can be used for covering increased heat loads on the air cooler and to reduce the refrigeration capacity of the absorption lithium-bromidechiller applied. To solve this task the refrigeration capacity required for gas turbine unit inlet air cooling is compared with an excessive refrigeration capacity of the absorption lithium-bromidechiller exceeding current heat loads summarized during 10 days of July 2015. The system of gas turbine unit inlet air cooling with a buster stage of precooling air and a base stage of cooling air to the temperature of about 15 °C by absorption lithium-bromide chiller has been proposed. An excessive refrigeration capacity of the absorption chiller generated during decreased heat loads on the gas turbine unit inlet air cooler that is collected in the thermal accumulator is used for gas turbine unit inlet air precooling in a buster stage of air cooler during increased heat loads on the air cooler. The results of gas turbine unit inlet air cooling processes simulation proved the reduction of refrigeration capacity of the absorption lithium-bromide chiller applied by 30-40 % due to the use of a buster stage of precooling air at the expanse of an excessive absorptionchiller refrigeration capacity served in the thermal accumulator. So the conclusion has been made about the efficient use of a buster stage of gas turbine unit inlet air cooler for precooling air by using an excessive refrigeration potential of absorption lithium-bromidechiller coolant saved in the thermal accumulator
first_indexed 2024-03-12T07:49:21Z
format Article
id doaj.art-cf1be59565ad4af2a4366411dc681961
institution Directory Open Access Journal
issn 1727-7337
2663-2217
language English
last_indexed 2024-03-12T07:49:21Z
publishDate 2018-02-01
publisher National Aerospace University «Kharkiv Aviation Institute»
record_format Article
series Авіаційно-космічна техніка та технологія
spelling doaj.art-cf1be59565ad4af2a4366411dc6819612023-09-02T20:45:35ZengNational Aerospace University «Kharkiv Aviation Institute»Авіаційно-космічна техніка та технологія1727-73372663-22172018-02-0101646910.32620/aktt.2018.1.0730GAS TURBINE UNITE INLET AIR COOLING BY USING AN EXCESSIVE REFRIGERATION CAPACITY OF ABSORPTION CHILLER IN BUSTER AIR COOLERАндрій Миколайович Радченко0Роман Миколайович Радченко1Сергій Анатолійович Кантор2Богдан Сергійович Портной3Веніамін Сергійович Ткаченко4Національний університет кораблебудування ім. адмірала Макарова, Миколаїв, УкраїнаНаціональний університет кораблебудування ім. адмірала Макарова, Миколаїв, УкраїнаПАТ "Завод "Екватор", Миколаїв, УкраїнаНаціональний університет кораблебудування ім. адмірала Макарова, Миколаїв, УкраїнаПАТ "Завод "Екватор", Миколаїв, УкраїнаThe processes of gas turbine unit inlet air cooling by absorption lithium-bromide chiller utilizing the turbine exhaust gas waste heat as athermotransformer has been analyzed for hour-by-hour changing ambient air temperatures and changeable heat loads on the air cooler as consequence. The computer programs of the firms-producers of heat exchangers were used for gas turbine unit inlet air cooling processes simulation. It is shown that at decreased heat loads on the air cooler an excessive refrigeration capacity of the absorption lithium-bromidechiller exceeding current heat loads is generated which can be used for covering increased heat loads on the air cooler and to reduce the refrigeration capacity of the absorption lithium-bromidechiller applied. To solve this task the refrigeration capacity required for gas turbine unit inlet air cooling is compared with an excessive refrigeration capacity of the absorption lithium-bromidechiller exceeding current heat loads summarized during 10 days of July 2015. The system of gas turbine unit inlet air cooling with a buster stage of precooling air and a base stage of cooling air to the temperature of about 15 °C by absorption lithium-bromide chiller has been proposed. An excessive refrigeration capacity of the absorption chiller generated during decreased heat loads on the gas turbine unit inlet air cooler that is collected in the thermal accumulator is used for gas turbine unit inlet air precooling in a buster stage of air cooler during increased heat loads on the air cooler. The results of gas turbine unit inlet air cooling processes simulation proved the reduction of refrigeration capacity of the absorption lithium-bromide chiller applied by 30-40 % due to the use of a buster stage of precooling air at the expanse of an excessive absorptionchiller refrigeration capacity served in the thermal accumulator. So the conclusion has been made about the efficient use of a buster stage of gas turbine unit inlet air cooler for precooling air by using an excessive refrigeration potential of absorption lithium-bromidechiller coolant saved in the thermal accumulatorhttp://nti.khai.edu/ojs/index.php/aktt/article/view/31охолодженняповітрятеплове навантаженнябустерний повітроохолоджувачабсорбційна холодильна машина
spellingShingle Андрій Миколайович Радченко
Роман Миколайович Радченко
Сергій Анатолійович Кантор
Богдан Сергійович Портной
Веніамін Сергійович Ткаченко
GAS TURBINE UNITE INLET AIR COOLING BY USING AN EXCESSIVE REFRIGERATION CAPACITY OF ABSORPTION CHILLER IN BUSTER AIR COOLER
Авіаційно-космічна техніка та технологія
охолодження
повітря
теплове навантаження
бустерний повітроохолоджувач
абсорбційна холодильна машина
title GAS TURBINE UNITE INLET AIR COOLING BY USING AN EXCESSIVE REFRIGERATION CAPACITY OF ABSORPTION CHILLER IN BUSTER AIR COOLER
title_full GAS TURBINE UNITE INLET AIR COOLING BY USING AN EXCESSIVE REFRIGERATION CAPACITY OF ABSORPTION CHILLER IN BUSTER AIR COOLER
title_fullStr GAS TURBINE UNITE INLET AIR COOLING BY USING AN EXCESSIVE REFRIGERATION CAPACITY OF ABSORPTION CHILLER IN BUSTER AIR COOLER
title_full_unstemmed GAS TURBINE UNITE INLET AIR COOLING BY USING AN EXCESSIVE REFRIGERATION CAPACITY OF ABSORPTION CHILLER IN BUSTER AIR COOLER
title_short GAS TURBINE UNITE INLET AIR COOLING BY USING AN EXCESSIVE REFRIGERATION CAPACITY OF ABSORPTION CHILLER IN BUSTER AIR COOLER
title_sort gas turbine unite inlet air cooling by using an excessive refrigeration capacity of absorption chiller in buster air cooler
topic охолодження
повітря
теплове навантаження
бустерний повітроохолоджувач
абсорбційна холодильна машина
url http://nti.khai.edu/ojs/index.php/aktt/article/view/31
work_keys_str_mv AT andríjmikolajovičradčenko gasturbineuniteinletaircoolingbyusinganexcessiverefrigerationcapacityofabsorptionchillerinbusteraircooler
AT romanmikolajovičradčenko gasturbineuniteinletaircoolingbyusinganexcessiverefrigerationcapacityofabsorptionchillerinbusteraircooler
AT sergíjanatolíjovičkantor gasturbineuniteinletaircoolingbyusinganexcessiverefrigerationcapacityofabsorptionchillerinbusteraircooler
AT bogdansergíjovičportnoj gasturbineuniteinletaircoolingbyusinganexcessiverefrigerationcapacityofabsorptionchillerinbusteraircooler
AT veníamínsergíjovičtkačenko gasturbineuniteinletaircoolingbyusinganexcessiverefrigerationcapacityofabsorptionchillerinbusteraircooler