Mass Transfer Analysis of Air-Cooled Membrane Distillation Configuration for Desalination
It has been proposed that the air-cooled configuration for air gap membrane distillation is an effective way to simplify the system design and energy source requirement. This offers potential for the practical applications of membrane distillation on an industrial scale. In this work, membrane disti...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-04-01
|
Series: | Membranes |
Subjects: | |
Online Access: | https://www.mdpi.com/2077-0375/11/4/281 |
_version_ | 1797538153169420288 |
---|---|
author | Shuo Cong Qingxiu Miao Fei Guo |
author_facet | Shuo Cong Qingxiu Miao Fei Guo |
author_sort | Shuo Cong |
collection | DOAJ |
description | It has been proposed that the air-cooled configuration for air gap membrane distillation is an effective way to simplify the system design and energy source requirement. This offers potential for the practical applications of membrane distillation on an industrial scale. In this work, membrane distillation tests were performed using a typical water-cooled membrane distillation (WCMD) configuration and an air-cooled membrane distillation (ACMD) configuration with various condensing plates and operating conditions. To increase the permeate flux of an ACMD system, the condensing plate in the permeate side should transfer heat to the atmosphere more effectively, such as using a more thermally conductive plate, adding fins, or introducing forced convection air flow. Importantly, a practical mass transfer model was proposed to describe the ACMD performance in terms of permeate flux. This model can be simplified by introducing specific correction values to the mass transfer coefficient of a WCMD process under the same conditions. The two factors relate to the capacity (<i>B</i>) and the efficiency (σ), which can be considered as the characteristic factors of a membrane distillation (MD) system. The experimental results are consistent with the theoretical estimations based on this model, which can be used to describe the performance of an MD process. |
first_indexed | 2024-03-10T12:26:28Z |
format | Article |
id | doaj.art-cf2a1513b038435b84fffee61a4a0515 |
institution | Directory Open Access Journal |
issn | 2077-0375 |
language | English |
last_indexed | 2024-03-10T12:26:28Z |
publishDate | 2021-04-01 |
publisher | MDPI AG |
record_format | Article |
series | Membranes |
spelling | doaj.art-cf2a1513b038435b84fffee61a4a05152023-11-21T15:02:37ZengMDPI AGMembranes2077-03752021-04-0111428110.3390/membranes11040281Mass Transfer Analysis of Air-Cooled Membrane Distillation Configuration for DesalinationShuo Cong0Qingxiu Miao1Fei Guo2Key Laboratory of Ocean Energy Utilization and Energy Conservation of Ministry of Education, School of Energy and Power Engineering, Dalian University of Technology, No. 2 Linggong Road, Dalian 116024, ChinaKey Laboratory of Ocean Energy Utilization and Energy Conservation of Ministry of Education, School of Energy and Power Engineering, Dalian University of Technology, No. 2 Linggong Road, Dalian 116024, ChinaKey Laboratory of Ocean Energy Utilization and Energy Conservation of Ministry of Education, School of Energy and Power Engineering, Dalian University of Technology, No. 2 Linggong Road, Dalian 116024, ChinaIt has been proposed that the air-cooled configuration for air gap membrane distillation is an effective way to simplify the system design and energy source requirement. This offers potential for the practical applications of membrane distillation on an industrial scale. In this work, membrane distillation tests were performed using a typical water-cooled membrane distillation (WCMD) configuration and an air-cooled membrane distillation (ACMD) configuration with various condensing plates and operating conditions. To increase the permeate flux of an ACMD system, the condensing plate in the permeate side should transfer heat to the atmosphere more effectively, such as using a more thermally conductive plate, adding fins, or introducing forced convection air flow. Importantly, a practical mass transfer model was proposed to describe the ACMD performance in terms of permeate flux. This model can be simplified by introducing specific correction values to the mass transfer coefficient of a WCMD process under the same conditions. The two factors relate to the capacity (<i>B</i>) and the efficiency (σ), which can be considered as the characteristic factors of a membrane distillation (MD) system. The experimental results are consistent with the theoretical estimations based on this model, which can be used to describe the performance of an MD process.https://www.mdpi.com/2077-0375/11/4/281air-cooled membrane distillationmass transfer modelcharacteristic factorpermeate flux |
spellingShingle | Shuo Cong Qingxiu Miao Fei Guo Mass Transfer Analysis of Air-Cooled Membrane Distillation Configuration for Desalination Membranes air-cooled membrane distillation mass transfer model characteristic factor permeate flux |
title | Mass Transfer Analysis of Air-Cooled Membrane Distillation Configuration for Desalination |
title_full | Mass Transfer Analysis of Air-Cooled Membrane Distillation Configuration for Desalination |
title_fullStr | Mass Transfer Analysis of Air-Cooled Membrane Distillation Configuration for Desalination |
title_full_unstemmed | Mass Transfer Analysis of Air-Cooled Membrane Distillation Configuration for Desalination |
title_short | Mass Transfer Analysis of Air-Cooled Membrane Distillation Configuration for Desalination |
title_sort | mass transfer analysis of air cooled membrane distillation configuration for desalination |
topic | air-cooled membrane distillation mass transfer model characteristic factor permeate flux |
url | https://www.mdpi.com/2077-0375/11/4/281 |
work_keys_str_mv | AT shuocong masstransferanalysisofaircooledmembranedistillationconfigurationfordesalination AT qingxiumiao masstransferanalysisofaircooledmembranedistillationconfigurationfordesalination AT feiguo masstransferanalysisofaircooledmembranedistillationconfigurationfordesalination |