Features of Tonometric Indicators Obtained by the Corneal Biomechanical Properties Analyzer Using Corneal Imaging Technology CorVis ST, Oculus in Real Clinical Practice

Objective: to analyze the tonometric data, obtained with standard contactless tonometry and corneal-compensated tonometry, examined by the Oculus CorVis ST device in different groups of patients of the Tri-Z Krasnodar Clinic.Patients and Methods. The study included 42 eyes of patients, with glaucoma...

Full description

Bibliographic Details
Main Authors: A. S. Apostolova, A. V. Malyshev, A. A. Sergienko, A. E. Oparina, M. A. Slavova
Format: Article
Language:Russian
Published: Ophthalmology Publishing Group 2023-01-01
Series:Oftalʹmologiâ
Subjects:
Online Access:https://www.ophthalmojournal.com/opht/article/view/1988
_version_ 1797875407467315200
author A. S. Apostolova
A. V. Malyshev
A. A. Sergienko
A. E. Oparina
M. A. Slavova
author_facet A. S. Apostolova
A. V. Malyshev
A. A. Sergienko
A. E. Oparina
M. A. Slavova
author_sort A. S. Apostolova
collection DOAJ
description Objective: to analyze the tonometric data, obtained with standard contactless tonometry and corneal-compensated tonometry, examined by the Oculus CorVis ST device in different groups of patients of the Tri-Z Krasnodar Clinic.Patients and Methods. The study included 42 eyes of patients, with glaucoma — 55 %, with suspected glaucoma — 45 %, mean age — 63.19 ± 1.7 years, men were 20 (47.5 %), women — 22 (52.5 %), the central corneal thickness was 554.43 ± 5.28 microns. Corneal tomography and biomechanical parameters were measured using Pentacam (Oculus) and Corvus ST, respectively.Results. IOP in people aged over 60 years was lower according to CorVis ST (Po 22.07 = 2.25, Pcс 18.63 ± 1.30, p = 0.007). IOP differed only in patients with a CCT of more than 580 µm (Po 22.4 ± 2.9, Pcc 18.21 ± 2.16, p = 0.012). IOP in patients with glaucoma was Ро 26.19 ± 3.5 and Рсс 21.3 ± 2.0, p = 0.008, without glaucoma — Ро 17.83 ± 9.60; Pсс 16.1 ± 5.5; p = 0.063. IOP in patients with compensated glaucoma Ро 17.34 ± 1.10, Pсс 16.6 ± 1.1, p = 0.354, with decompensated Ро 42.78 ± 6.8, Pсс 30.08 ± 4.10, p = 0.005. In the initial stage of glaucoma, Рo 22.5 ± 2.3, Рсс 20.0 ± 1.0, p = 0.297, in the advanced stage — Рo 20.7 ± 2.7, Рсс 17.6 ± 1.9, p = 0.027.Conclusion. Standard non-contact tonometry can be used in persons aged under 60 years, persons without glaucoma and with initial compensated glaucoma. In all other cases, the Oculus CorVis ST values are more accurate.
first_indexed 2024-04-10T01:46:03Z
format Article
id doaj.art-cf2cfe1592a64cd5b12174d40886c943
institution Directory Open Access Journal
issn 1816-5095
2500-0845
language Russian
last_indexed 2024-04-10T01:46:03Z
publishDate 2023-01-01
publisher Ophthalmology Publishing Group
record_format Article
series Oftalʹmologiâ
spelling doaj.art-cf2cfe1592a64cd5b12174d40886c9432023-03-13T09:08:43ZrusOphthalmology Publishing GroupOftalʹmologiâ1816-50952500-08452023-01-0119479780210.18008/1816-5095-2022-4-797-802974Features of Tonometric Indicators Obtained by the Corneal Biomechanical Properties Analyzer Using Corneal Imaging Technology CorVis ST, Oculus in Real Clinical PracticeA. S. Apostolova0A. V. Malyshev1A. A. Sergienko2A. E. Oparina3M. A. Slavova4ООО «Три-З»ГБУЗ «Научно-исследовательский институт — Краевая клиническая больница № 1 им. профессора С.В. Очаповского» Министерства здравоохранения Краснодарского краяГБУЗ «Детская краевая клиническая больница» Министерства здравоохранения Краснодарского краяООО «Три-З»ООО «Три-З»Objective: to analyze the tonometric data, obtained with standard contactless tonometry and corneal-compensated tonometry, examined by the Oculus CorVis ST device in different groups of patients of the Tri-Z Krasnodar Clinic.Patients and Methods. The study included 42 eyes of patients, with glaucoma — 55 %, with suspected glaucoma — 45 %, mean age — 63.19 ± 1.7 years, men were 20 (47.5 %), women — 22 (52.5 %), the central corneal thickness was 554.43 ± 5.28 microns. Corneal tomography and biomechanical parameters were measured using Pentacam (Oculus) and Corvus ST, respectively.Results. IOP in people aged over 60 years was lower according to CorVis ST (Po 22.07 = 2.25, Pcс 18.63 ± 1.30, p = 0.007). IOP differed only in patients with a CCT of more than 580 µm (Po 22.4 ± 2.9, Pcc 18.21 ± 2.16, p = 0.012). IOP in patients with glaucoma was Ро 26.19 ± 3.5 and Рсс 21.3 ± 2.0, p = 0.008, without glaucoma — Ро 17.83 ± 9.60; Pсс 16.1 ± 5.5; p = 0.063. IOP in patients with compensated glaucoma Ро 17.34 ± 1.10, Pсс 16.6 ± 1.1, p = 0.354, with decompensated Ро 42.78 ± 6.8, Pсс 30.08 ± 4.10, p = 0.005. In the initial stage of glaucoma, Рo 22.5 ± 2.3, Рсс 20.0 ± 1.0, p = 0.297, in the advanced stage — Рo 20.7 ± 2.7, Рсс 17.6 ± 1.9, p = 0.027.Conclusion. Standard non-contact tonometry can be used in persons aged under 60 years, persons without glaucoma and with initial compensated glaucoma. In all other cases, the Oculus CorVis ST values are more accurate.https://www.ophthalmojournal.com/opht/article/view/1988первичная открытоугольная глаукомацентральная толщина роговицытонометрияроговично-компенсированное давлениебиомеханические свойства роговицы
spellingShingle A. S. Apostolova
A. V. Malyshev
A. A. Sergienko
A. E. Oparina
M. A. Slavova
Features of Tonometric Indicators Obtained by the Corneal Biomechanical Properties Analyzer Using Corneal Imaging Technology CorVis ST, Oculus in Real Clinical Practice
Oftalʹmologiâ
первичная открытоугольная глаукома
центральная толщина роговицы
тонометрия
роговично-компенсированное давление
биомеханические свойства роговицы
title Features of Tonometric Indicators Obtained by the Corneal Biomechanical Properties Analyzer Using Corneal Imaging Technology CorVis ST, Oculus in Real Clinical Practice
title_full Features of Tonometric Indicators Obtained by the Corneal Biomechanical Properties Analyzer Using Corneal Imaging Technology CorVis ST, Oculus in Real Clinical Practice
title_fullStr Features of Tonometric Indicators Obtained by the Corneal Biomechanical Properties Analyzer Using Corneal Imaging Technology CorVis ST, Oculus in Real Clinical Practice
title_full_unstemmed Features of Tonometric Indicators Obtained by the Corneal Biomechanical Properties Analyzer Using Corneal Imaging Technology CorVis ST, Oculus in Real Clinical Practice
title_short Features of Tonometric Indicators Obtained by the Corneal Biomechanical Properties Analyzer Using Corneal Imaging Technology CorVis ST, Oculus in Real Clinical Practice
title_sort features of tonometric indicators obtained by the corneal biomechanical properties analyzer using corneal imaging technology corvis st oculus in real clinical practice
topic первичная открытоугольная глаукома
центральная толщина роговицы
тонометрия
роговично-компенсированное давление
биомеханические свойства роговицы
url https://www.ophthalmojournal.com/opht/article/view/1988
work_keys_str_mv AT asapostolova featuresoftonometricindicatorsobtainedbythecornealbiomechanicalpropertiesanalyzerusingcornealimagingtechnologycorvisstoculusinrealclinicalpractice
AT avmalyshev featuresoftonometricindicatorsobtainedbythecornealbiomechanicalpropertiesanalyzerusingcornealimagingtechnologycorvisstoculusinrealclinicalpractice
AT aasergienko featuresoftonometricindicatorsobtainedbythecornealbiomechanicalpropertiesanalyzerusingcornealimagingtechnologycorvisstoculusinrealclinicalpractice
AT aeoparina featuresoftonometricindicatorsobtainedbythecornealbiomechanicalpropertiesanalyzerusingcornealimagingtechnologycorvisstoculusinrealclinicalpractice
AT maslavova featuresoftonometricindicatorsobtainedbythecornealbiomechanicalpropertiesanalyzerusingcornealimagingtechnologycorvisstoculusinrealclinicalpractice