Features of Tonometric Indicators Obtained by the Corneal Biomechanical Properties Analyzer Using Corneal Imaging Technology CorVis ST, Oculus in Real Clinical Practice
Objective: to analyze the tonometric data, obtained with standard contactless tonometry and corneal-compensated tonometry, examined by the Oculus CorVis ST device in different groups of patients of the Tri-Z Krasnodar Clinic.Patients and Methods. The study included 42 eyes of patients, with glaucoma...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Ophthalmology Publishing Group
2023-01-01
|
Series: | Oftalʹmologiâ |
Subjects: | |
Online Access: | https://www.ophthalmojournal.com/opht/article/view/1988 |
_version_ | 1797875407467315200 |
---|---|
author | A. S. Apostolova A. V. Malyshev A. A. Sergienko A. E. Oparina M. A. Slavova |
author_facet | A. S. Apostolova A. V. Malyshev A. A. Sergienko A. E. Oparina M. A. Slavova |
author_sort | A. S. Apostolova |
collection | DOAJ |
description | Objective: to analyze the tonometric data, obtained with standard contactless tonometry and corneal-compensated tonometry, examined by the Oculus CorVis ST device in different groups of patients of the Tri-Z Krasnodar Clinic.Patients and Methods. The study included 42 eyes of patients, with glaucoma — 55 %, with suspected glaucoma — 45 %, mean age — 63.19 ± 1.7 years, men were 20 (47.5 %), women — 22 (52.5 %), the central corneal thickness was 554.43 ± 5.28 microns. Corneal tomography and biomechanical parameters were measured using Pentacam (Oculus) and Corvus ST, respectively.Results. IOP in people aged over 60 years was lower according to CorVis ST (Po 22.07 = 2.25, Pcс 18.63 ± 1.30, p = 0.007). IOP differed only in patients with a CCT of more than 580 µm (Po 22.4 ± 2.9, Pcc 18.21 ± 2.16, p = 0.012). IOP in patients with glaucoma was Ро 26.19 ± 3.5 and Рсс 21.3 ± 2.0, p = 0.008, without glaucoma — Ро 17.83 ± 9.60; Pсс 16.1 ± 5.5; p = 0.063. IOP in patients with compensated glaucoma Ро 17.34 ± 1.10, Pсс 16.6 ± 1.1, p = 0.354, with decompensated Ро 42.78 ± 6.8, Pсс 30.08 ± 4.10, p = 0.005. In the initial stage of glaucoma, Рo 22.5 ± 2.3, Рсс 20.0 ± 1.0, p = 0.297, in the advanced stage — Рo 20.7 ± 2.7, Рсс 17.6 ± 1.9, p = 0.027.Conclusion. Standard non-contact tonometry can be used in persons aged under 60 years, persons without glaucoma and with initial compensated glaucoma. In all other cases, the Oculus CorVis ST values are more accurate. |
first_indexed | 2024-04-10T01:46:03Z |
format | Article |
id | doaj.art-cf2cfe1592a64cd5b12174d40886c943 |
institution | Directory Open Access Journal |
issn | 1816-5095 2500-0845 |
language | Russian |
last_indexed | 2024-04-10T01:46:03Z |
publishDate | 2023-01-01 |
publisher | Ophthalmology Publishing Group |
record_format | Article |
series | Oftalʹmologiâ |
spelling | doaj.art-cf2cfe1592a64cd5b12174d40886c9432023-03-13T09:08:43ZrusOphthalmology Publishing GroupOftalʹmologiâ1816-50952500-08452023-01-0119479780210.18008/1816-5095-2022-4-797-802974Features of Tonometric Indicators Obtained by the Corneal Biomechanical Properties Analyzer Using Corneal Imaging Technology CorVis ST, Oculus in Real Clinical PracticeA. S. Apostolova0A. V. Malyshev1A. A. Sergienko2A. E. Oparina3M. A. Slavova4ООО «Три-З»ГБУЗ «Научно-исследовательский институт — Краевая клиническая больница № 1 им. профессора С.В. Очаповского» Министерства здравоохранения Краснодарского краяГБУЗ «Детская краевая клиническая больница» Министерства здравоохранения Краснодарского краяООО «Три-З»ООО «Три-З»Objective: to analyze the tonometric data, obtained with standard contactless tonometry and corneal-compensated tonometry, examined by the Oculus CorVis ST device in different groups of patients of the Tri-Z Krasnodar Clinic.Patients and Methods. The study included 42 eyes of patients, with glaucoma — 55 %, with suspected glaucoma — 45 %, mean age — 63.19 ± 1.7 years, men were 20 (47.5 %), women — 22 (52.5 %), the central corneal thickness was 554.43 ± 5.28 microns. Corneal tomography and biomechanical parameters were measured using Pentacam (Oculus) and Corvus ST, respectively.Results. IOP in people aged over 60 years was lower according to CorVis ST (Po 22.07 = 2.25, Pcс 18.63 ± 1.30, p = 0.007). IOP differed only in patients with a CCT of more than 580 µm (Po 22.4 ± 2.9, Pcc 18.21 ± 2.16, p = 0.012). IOP in patients with glaucoma was Ро 26.19 ± 3.5 and Рсс 21.3 ± 2.0, p = 0.008, without glaucoma — Ро 17.83 ± 9.60; Pсс 16.1 ± 5.5; p = 0.063. IOP in patients with compensated glaucoma Ро 17.34 ± 1.10, Pсс 16.6 ± 1.1, p = 0.354, with decompensated Ро 42.78 ± 6.8, Pсс 30.08 ± 4.10, p = 0.005. In the initial stage of glaucoma, Рo 22.5 ± 2.3, Рсс 20.0 ± 1.0, p = 0.297, in the advanced stage — Рo 20.7 ± 2.7, Рсс 17.6 ± 1.9, p = 0.027.Conclusion. Standard non-contact tonometry can be used in persons aged under 60 years, persons without glaucoma and with initial compensated glaucoma. In all other cases, the Oculus CorVis ST values are more accurate.https://www.ophthalmojournal.com/opht/article/view/1988первичная открытоугольная глаукомацентральная толщина роговицытонометрияроговично-компенсированное давлениебиомеханические свойства роговицы |
spellingShingle | A. S. Apostolova A. V. Malyshev A. A. Sergienko A. E. Oparina M. A. Slavova Features of Tonometric Indicators Obtained by the Corneal Biomechanical Properties Analyzer Using Corneal Imaging Technology CorVis ST, Oculus in Real Clinical Practice Oftalʹmologiâ первичная открытоугольная глаукома центральная толщина роговицы тонометрия роговично-компенсированное давление биомеханические свойства роговицы |
title | Features of Tonometric Indicators Obtained by the Corneal Biomechanical Properties Analyzer Using Corneal Imaging Technology CorVis ST, Oculus in Real Clinical Practice |
title_full | Features of Tonometric Indicators Obtained by the Corneal Biomechanical Properties Analyzer Using Corneal Imaging Technology CorVis ST, Oculus in Real Clinical Practice |
title_fullStr | Features of Tonometric Indicators Obtained by the Corneal Biomechanical Properties Analyzer Using Corneal Imaging Technology CorVis ST, Oculus in Real Clinical Practice |
title_full_unstemmed | Features of Tonometric Indicators Obtained by the Corneal Biomechanical Properties Analyzer Using Corneal Imaging Technology CorVis ST, Oculus in Real Clinical Practice |
title_short | Features of Tonometric Indicators Obtained by the Corneal Biomechanical Properties Analyzer Using Corneal Imaging Technology CorVis ST, Oculus in Real Clinical Practice |
title_sort | features of tonometric indicators obtained by the corneal biomechanical properties analyzer using corneal imaging technology corvis st oculus in real clinical practice |
topic | первичная открытоугольная глаукома центральная толщина роговицы тонометрия роговично-компенсированное давление биомеханические свойства роговицы |
url | https://www.ophthalmojournal.com/opht/article/view/1988 |
work_keys_str_mv | AT asapostolova featuresoftonometricindicatorsobtainedbythecornealbiomechanicalpropertiesanalyzerusingcornealimagingtechnologycorvisstoculusinrealclinicalpractice AT avmalyshev featuresoftonometricindicatorsobtainedbythecornealbiomechanicalpropertiesanalyzerusingcornealimagingtechnologycorvisstoculusinrealclinicalpractice AT aasergienko featuresoftonometricindicatorsobtainedbythecornealbiomechanicalpropertiesanalyzerusingcornealimagingtechnologycorvisstoculusinrealclinicalpractice AT aeoparina featuresoftonometricindicatorsobtainedbythecornealbiomechanicalpropertiesanalyzerusingcornealimagingtechnologycorvisstoculusinrealclinicalpractice AT maslavova featuresoftonometricindicatorsobtainedbythecornealbiomechanicalpropertiesanalyzerusingcornealimagingtechnologycorvisstoculusinrealclinicalpractice |