Evaluation of quantitative accuracy among different scatter corrections for quantitative bone SPECT/CT imaging.

Although scatter correction improves SPECT image contrast and thus image quality, the effects of quantitation accuracy under various conditions remain unclear. The present study aimed to empirically define the conditions for the optimal scatter correction of quantitative bone SPECT/CT images. Scatte...

Full description

Bibliographic Details
Main Authors: Kenta Miwa, Reo Nemoto, Hirotsugu Masuko, Tensho Yamao, Rinya Kobayashi, Noriaki Miyaji, Kosuke Inoue, Hiroya Onodera
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2022-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0269542
_version_ 1818469354166026240
author Kenta Miwa
Reo Nemoto
Hirotsugu Masuko
Tensho Yamao
Rinya Kobayashi
Noriaki Miyaji
Kosuke Inoue
Hiroya Onodera
author_facet Kenta Miwa
Reo Nemoto
Hirotsugu Masuko
Tensho Yamao
Rinya Kobayashi
Noriaki Miyaji
Kosuke Inoue
Hiroya Onodera
author_sort Kenta Miwa
collection DOAJ
description Although scatter correction improves SPECT image contrast and thus image quality, the effects of quantitation accuracy under various conditions remain unclear. The present study aimed to empirically define the conditions for the optimal scatter correction of quantitative bone SPECT/CT images. Scatter correction was performed by applying dual and triple energy windows (DEW and TEW) with different sub-energy window widths, and effective scatter source estimation (ESSE) to CT-based scatter correction. Scattered radiation was corrected on images acquired using a triple line source (TLSP) phantom and an uniform cylinder phantom. The TLSP consisted of a line source containing 74.0 MBq of 99mTc in the middle, and a background component containing air, water or a K2HPO4 solution with a density equivalent to that of bone. The sum of all pixels in air, water and the K2HPO4 solution was measured on SPECT images. Scatter fraction (SF) and normalized mean square error (NMSE) based on counts from the air background as a reference were then calculated to assess quantitative errors due to scatter correction. The uniform cylinder phantom contained the same K2HPO4 solution and 222.0 MBq of 99mTc. The coefficient of variation (CV) was calculated from the count profile of this phantom to assess the uniformity of SPECT images across scatter correction under various conditions. Both SF and NMSE in SPECT images of phantoms containing water in the background were lower at a TEW sub-window of 3% (TEW3%), than in other scatter corrections, whereas those in K2HPO4 were lower at a DEW sub-window of 20% (DEW20%). Larger DEW and smaller TEW sub-energy windows allowed more effective correction. The CV of the uniform cylinder phantom, DEW20%, was inferior to all other tested scatter corrections. The quantitative accuracy of bone SPECT images substantially differed according to the method of scatter correction. The optimal scatter correction for quantitative bone SPECT was DEW20% (k = 1), but at the cost of slightly decreased image uniformity.
first_indexed 2024-04-13T21:22:32Z
format Article
id doaj.art-cf2f3dac928d4205be0b3dc36288453e
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-04-13T21:22:32Z
publishDate 2022-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-cf2f3dac928d4205be0b3dc36288453e2022-12-22T02:29:25ZengPublic Library of Science (PLoS)PLoS ONE1932-62032022-01-01176e026954210.1371/journal.pone.0269542Evaluation of quantitative accuracy among different scatter corrections for quantitative bone SPECT/CT imaging.Kenta MiwaReo NemotoHirotsugu MasukoTensho YamaoRinya KobayashiNoriaki MiyajiKosuke InoueHiroya OnoderaAlthough scatter correction improves SPECT image contrast and thus image quality, the effects of quantitation accuracy under various conditions remain unclear. The present study aimed to empirically define the conditions for the optimal scatter correction of quantitative bone SPECT/CT images. Scatter correction was performed by applying dual and triple energy windows (DEW and TEW) with different sub-energy window widths, and effective scatter source estimation (ESSE) to CT-based scatter correction. Scattered radiation was corrected on images acquired using a triple line source (TLSP) phantom and an uniform cylinder phantom. The TLSP consisted of a line source containing 74.0 MBq of 99mTc in the middle, and a background component containing air, water or a K2HPO4 solution with a density equivalent to that of bone. The sum of all pixels in air, water and the K2HPO4 solution was measured on SPECT images. Scatter fraction (SF) and normalized mean square error (NMSE) based on counts from the air background as a reference were then calculated to assess quantitative errors due to scatter correction. The uniform cylinder phantom contained the same K2HPO4 solution and 222.0 MBq of 99mTc. The coefficient of variation (CV) was calculated from the count profile of this phantom to assess the uniformity of SPECT images across scatter correction under various conditions. Both SF and NMSE in SPECT images of phantoms containing water in the background were lower at a TEW sub-window of 3% (TEW3%), than in other scatter corrections, whereas those in K2HPO4 were lower at a DEW sub-window of 20% (DEW20%). Larger DEW and smaller TEW sub-energy windows allowed more effective correction. The CV of the uniform cylinder phantom, DEW20%, was inferior to all other tested scatter corrections. The quantitative accuracy of bone SPECT images substantially differed according to the method of scatter correction. The optimal scatter correction for quantitative bone SPECT was DEW20% (k = 1), but at the cost of slightly decreased image uniformity.https://doi.org/10.1371/journal.pone.0269542
spellingShingle Kenta Miwa
Reo Nemoto
Hirotsugu Masuko
Tensho Yamao
Rinya Kobayashi
Noriaki Miyaji
Kosuke Inoue
Hiroya Onodera
Evaluation of quantitative accuracy among different scatter corrections for quantitative bone SPECT/CT imaging.
PLoS ONE
title Evaluation of quantitative accuracy among different scatter corrections for quantitative bone SPECT/CT imaging.
title_full Evaluation of quantitative accuracy among different scatter corrections for quantitative bone SPECT/CT imaging.
title_fullStr Evaluation of quantitative accuracy among different scatter corrections for quantitative bone SPECT/CT imaging.
title_full_unstemmed Evaluation of quantitative accuracy among different scatter corrections for quantitative bone SPECT/CT imaging.
title_short Evaluation of quantitative accuracy among different scatter corrections for quantitative bone SPECT/CT imaging.
title_sort evaluation of quantitative accuracy among different scatter corrections for quantitative bone spect ct imaging
url https://doi.org/10.1371/journal.pone.0269542
work_keys_str_mv AT kentamiwa evaluationofquantitativeaccuracyamongdifferentscattercorrectionsforquantitativebonespectctimaging
AT reonemoto evaluationofquantitativeaccuracyamongdifferentscattercorrectionsforquantitativebonespectctimaging
AT hirotsugumasuko evaluationofquantitativeaccuracyamongdifferentscattercorrectionsforquantitativebonespectctimaging
AT tenshoyamao evaluationofquantitativeaccuracyamongdifferentscattercorrectionsforquantitativebonespectctimaging
AT rinyakobayashi evaluationofquantitativeaccuracyamongdifferentscattercorrectionsforquantitativebonespectctimaging
AT noriakimiyaji evaluationofquantitativeaccuracyamongdifferentscattercorrectionsforquantitativebonespectctimaging
AT kosukeinoue evaluationofquantitativeaccuracyamongdifferentscattercorrectionsforquantitativebonespectctimaging
AT hiroyaonodera evaluationofquantitativeaccuracyamongdifferentscattercorrectionsforquantitativebonespectctimaging