Effect of spectrum measurement position on detection of Klason lignin content of snow pears by a portable NIR spectrometer

Abstract Snow pears are an important and widespread agricultural product that can relieve respiratory symptoms, constipation, and alcoholism. Lignin content (LC) has a direct and negative role on the fruit texture and taste of snow pears. Here, we studied the effect on the near‐infrared (NIR) spectr...

Full description

Bibliographic Details
Main Authors: Xin Wu, Guanglin Li, Xinglan Fu, Fengyun He, Weixin Wu
Format: Article
Language:English
Published: Wiley 2023-05-01
Series:Food and Energy Security
Subjects:
Online Access:https://doi.org/10.1002/fes3.447
_version_ 1811153977309396992
author Xin Wu
Guanglin Li
Xinglan Fu
Fengyun He
Weixin Wu
author_facet Xin Wu
Guanglin Li
Xinglan Fu
Fengyun He
Weixin Wu
author_sort Xin Wu
collection DOAJ
description Abstract Snow pears are an important and widespread agricultural product that can relieve respiratory symptoms, constipation, and alcoholism. Lignin content (LC) has a direct and negative role on the fruit texture and taste of snow pears. Here, we studied the effect on the near‐infrared (NIR) spectroscopy determination of the LC in snow pears due to the position at which spectral measurements were obtained. NIR diffuse reflection spectra were collected from nine measurement positions on each sample by a portable NIR spectrometer. Partial least squares regression (PLSR) was used to develop spectrum compensation models of the LC for three local spectrum models, an average spectrum model, and a global spectrum model. The results indicated that the prediction accuracy of the LC was affected by the spectral measurement position. Compared with the local spectrum models and the global spectrum model, the average spectrum model had good prediction results. Next, synergy interval partial least squares, bootstrapping soft shrinkage, competitive adaptive reweighted sampling, genetic algorithm, and an improved variable stability and frequency analysis algorithm (VSFAA) method were used to select the most effective variables to build the PLSR model. The average spectrum calibration model established using the 10 effective variables selected by VSFAA reduced the influence of the variation of the spectral measurement position for LC prediction and achieved more promising results, with the correlation coefficient of calibration and prediction of 0.842 and 0.824, respectively. The root mean square error of cross‐validation and prediction were 0.736 and 0.694, respectively. The overall results showed that the average spectrum model based on the nine spectral measurement positions reduced the sensitivity to the variation of spectral measurement position for predicting the LC and combined the VSFAA variable selection algorithm to improve the accuracy and provide a robust model for prediction of LC in snow pears. Compared with the local spectrum position models and the global spectrum position model, the average spectrum position model combining the nine measurement positions (three stem‐calyx longitudes intersected three latitudes (stem, equator, calyx)) produced good prediction results and reduced the sensitivity to the variation of the spectral measurement position. The effective wavelengths (SNV‐VSFAA‐PLSR)‐average spectrum position model achieved good results, reducing the influence of the variation of the spectral measurement position for LC prediction, and the effective wavelengths selected from the average spectrum position model were helpful for offsetting the influence of the variation of spectral measurement position on the PLSR models based on the spectrum from the equatorial positions alone.
first_indexed 2024-03-13T09:49:55Z
format Article
id doaj.art-cfb9f33967b148f8af33bd712f7d7c23
institution Directory Open Access Journal
issn 2048-3694
language English
last_indexed 2024-03-13T09:49:55Z
publishDate 2023-05-01
publisher Wiley
record_format Article
series Food and Energy Security
spelling doaj.art-cfb9f33967b148f8af33bd712f7d7c232023-05-24T14:36:38ZengWileyFood and Energy Security2048-36942023-05-01123n/an/a10.1002/fes3.447Effect of spectrum measurement position on detection of Klason lignin content of snow pears by a portable NIR spectrometerXin Wu0Guanglin Li1Xinglan Fu2Fengyun He3Weixin Wu4Chongqing College of Electronic Engineering Chongqing ChinaCollege of Engineering and Technology Southwest University Chongqing ChinaCollege of Engineering and Technology Southwest University Chongqing ChinaCollege of Engineering and Technology Southwest University Chongqing ChinaChongqing Academy of Metrology and Quality Inspection Chongqing ChinaAbstract Snow pears are an important and widespread agricultural product that can relieve respiratory symptoms, constipation, and alcoholism. Lignin content (LC) has a direct and negative role on the fruit texture and taste of snow pears. Here, we studied the effect on the near‐infrared (NIR) spectroscopy determination of the LC in snow pears due to the position at which spectral measurements were obtained. NIR diffuse reflection spectra were collected from nine measurement positions on each sample by a portable NIR spectrometer. Partial least squares regression (PLSR) was used to develop spectrum compensation models of the LC for three local spectrum models, an average spectrum model, and a global spectrum model. The results indicated that the prediction accuracy of the LC was affected by the spectral measurement position. Compared with the local spectrum models and the global spectrum model, the average spectrum model had good prediction results. Next, synergy interval partial least squares, bootstrapping soft shrinkage, competitive adaptive reweighted sampling, genetic algorithm, and an improved variable stability and frequency analysis algorithm (VSFAA) method were used to select the most effective variables to build the PLSR model. The average spectrum calibration model established using the 10 effective variables selected by VSFAA reduced the influence of the variation of the spectral measurement position for LC prediction and achieved more promising results, with the correlation coefficient of calibration and prediction of 0.842 and 0.824, respectively. The root mean square error of cross‐validation and prediction were 0.736 and 0.694, respectively. The overall results showed that the average spectrum model based on the nine spectral measurement positions reduced the sensitivity to the variation of spectral measurement position for predicting the LC and combined the VSFAA variable selection algorithm to improve the accuracy and provide a robust model for prediction of LC in snow pears. Compared with the local spectrum position models and the global spectrum position model, the average spectrum position model combining the nine measurement positions (three stem‐calyx longitudes intersected three latitudes (stem, equator, calyx)) produced good prediction results and reduced the sensitivity to the variation of the spectral measurement position. The effective wavelengths (SNV‐VSFAA‐PLSR)‐average spectrum position model achieved good results, reducing the influence of the variation of the spectral measurement position for LC prediction, and the effective wavelengths selected from the average spectrum position model were helpful for offsetting the influence of the variation of spectral measurement position on the PLSR models based on the spectrum from the equatorial positions alone.https://doi.org/10.1002/fes3.447lignin contentNIR spectroscopysnow pearsspectrum measurement positionVSFAA
spellingShingle Xin Wu
Guanglin Li
Xinglan Fu
Fengyun He
Weixin Wu
Effect of spectrum measurement position on detection of Klason lignin content of snow pears by a portable NIR spectrometer
Food and Energy Security
lignin content
NIR spectroscopy
snow pears
spectrum measurement position
VSFAA
title Effect of spectrum measurement position on detection of Klason lignin content of snow pears by a portable NIR spectrometer
title_full Effect of spectrum measurement position on detection of Klason lignin content of snow pears by a portable NIR spectrometer
title_fullStr Effect of spectrum measurement position on detection of Klason lignin content of snow pears by a portable NIR spectrometer
title_full_unstemmed Effect of spectrum measurement position on detection of Klason lignin content of snow pears by a portable NIR spectrometer
title_short Effect of spectrum measurement position on detection of Klason lignin content of snow pears by a portable NIR spectrometer
title_sort effect of spectrum measurement position on detection of klason lignin content of snow pears by a portable nir spectrometer
topic lignin content
NIR spectroscopy
snow pears
spectrum measurement position
VSFAA
url https://doi.org/10.1002/fes3.447
work_keys_str_mv AT xinwu effectofspectrummeasurementpositionondetectionofklasonlignincontentofsnowpearsbyaportablenirspectrometer
AT guanglinli effectofspectrummeasurementpositionondetectionofklasonlignincontentofsnowpearsbyaportablenirspectrometer
AT xinglanfu effectofspectrummeasurementpositionondetectionofklasonlignincontentofsnowpearsbyaportablenirspectrometer
AT fengyunhe effectofspectrummeasurementpositionondetectionofklasonlignincontentofsnowpearsbyaportablenirspectrometer
AT weixinwu effectofspectrummeasurementpositionondetectionofklasonlignincontentofsnowpearsbyaportablenirspectrometer