Design of a mine-used low-voltage leakage protection device

In view of low reliability of leakage protection device of coal mine low-voltage power grid based on line selection principle of zero-sequence power direction, a hardware and software design scheme of mine-used low-voltage leakage protection device was given. Fault line selection is realized accordi...

Full description

Bibliographic Details
Main Authors: ZHENG Qingle, RONG Xiang, YANG Fan, LI Rui
Format: Article
Language:zho
Published: Editorial Department of Industry and Mine Automation 2020-02-01
Series:Gong-kuang zidonghua
Subjects:
Online Access:http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.17505
_version_ 1828488911311077376
author ZHENG Qingle
RONG Xiang
YANG Fan
LI Rui
author_facet ZHENG Qingle
RONG Xiang
YANG Fan
LI Rui
author_sort ZHENG Qingle
collection DOAJ
description In view of low reliability of leakage protection device of coal mine low-voltage power grid based on line selection principle of zero-sequence power direction, a hardware and software design scheme of mine-used low-voltage leakage protection device was given. Fault line selection is realized according to differences of phase difference between zero-sequence current and zero-sequence voltage in non-fault branch and fault branch when single-phase grounding fault occurs in zero-sequence reactor grounding system with parallel resistance. The simulation and test results show that the device is not affected by zero sequence reactor compensation in power grid, and can operate quickly and reliably when single-phase grounding fault occurs.
first_indexed 2024-12-11T10:16:05Z
format Article
id doaj.art-cfd32d508d734bd0964fc2e7e16a3a34
institution Directory Open Access Journal
issn 1671-251X
language zho
last_indexed 2024-12-11T10:16:05Z
publishDate 2020-02-01
publisher Editorial Department of Industry and Mine Automation
record_format Article
series Gong-kuang zidonghua
spelling doaj.art-cfd32d508d734bd0964fc2e7e16a3a342022-12-22T01:11:36ZzhoEditorial Department of Industry and Mine AutomationGong-kuang zidonghua1671-251X2020-02-01462121710.13272/j.issn.1671-251x.17505Design of a mine-used low-voltage leakage protection deviceZHENG QingleRONG XiangYANG FanLI RuiIn view of low reliability of leakage protection device of coal mine low-voltage power grid based on line selection principle of zero-sequence power direction, a hardware and software design scheme of mine-used low-voltage leakage protection device was given. Fault line selection is realized according to differences of phase difference between zero-sequence current and zero-sequence voltage in non-fault branch and fault branch when single-phase grounding fault occurs in zero-sequence reactor grounding system with parallel resistance. The simulation and test results show that the device is not affected by zero sequence reactor compensation in power grid, and can operate quickly and reliably when single-phase grounding fault occurs.http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.17505low-voltage power grid of coal mineleakage protectionfault line selectionsingle-phase grounding faultzero-sequence reactor
spellingShingle ZHENG Qingle
RONG Xiang
YANG Fan
LI Rui
Design of a mine-used low-voltage leakage protection device
Gong-kuang zidonghua
low-voltage power grid of coal mine
leakage protection
fault line selection
single-phase grounding fault
zero-sequence reactor
title Design of a mine-used low-voltage leakage protection device
title_full Design of a mine-used low-voltage leakage protection device
title_fullStr Design of a mine-used low-voltage leakage protection device
title_full_unstemmed Design of a mine-used low-voltage leakage protection device
title_short Design of a mine-used low-voltage leakage protection device
title_sort design of a mine used low voltage leakage protection device
topic low-voltage power grid of coal mine
leakage protection
fault line selection
single-phase grounding fault
zero-sequence reactor
url http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.17505
work_keys_str_mv AT zhengqingle designofamineusedlowvoltageleakageprotectiondevice
AT rongxiang designofamineusedlowvoltageleakageprotectiondevice
AT yangfan designofamineusedlowvoltageleakageprotectiondevice
AT lirui designofamineusedlowvoltageleakageprotectiondevice