Utility of a novel wearable electrode embedded in an undershirt for electrocardiogram monitoring and detection of arrhythmias.

<h4>Background</h4>A 12-lead electrocardiogram (ECG) and Holter ECG have been established as gold standards for detection of arrhythmias. Recently, wearable ECG monitoring devices have been available. Our purpose of the present study was to investigate whether a novel wearable electrode...

Full description

Bibliographic Details
Main Authors: Kazuaki Amami, Akiomi Yoshihisa, Yuko Horikoshi, Shinya Yamada, Takeshi Nehashi, Naoko Hijioka, Minoru Nodera, Takashi Kaneshiro, Tetsuro Yokokawa, Tomofumi Misaka, Yasuchika Takeishi
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2022-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0273541
_version_ 1811262323019481088
author Kazuaki Amami
Akiomi Yoshihisa
Yuko Horikoshi
Shinya Yamada
Takeshi Nehashi
Naoko Hijioka
Minoru Nodera
Takashi Kaneshiro
Tetsuro Yokokawa
Tomofumi Misaka
Yasuchika Takeishi
author_facet Kazuaki Amami
Akiomi Yoshihisa
Yuko Horikoshi
Shinya Yamada
Takeshi Nehashi
Naoko Hijioka
Minoru Nodera
Takashi Kaneshiro
Tetsuro Yokokawa
Tomofumi Misaka
Yasuchika Takeishi
author_sort Kazuaki Amami
collection DOAJ
description <h4>Background</h4>A 12-lead electrocardiogram (ECG) and Holter ECG have been established as gold standards for detection of arrhythmias. Recently, wearable ECG monitoring devices have been available. Our purpose of the present study was to investigate whether a novel wearable electrode embedded in an undershirt is useful for ECG monitoring and detection of arrhythmias.<h4>Methods</h4>We studied 31 consecutive hospitalized patients who underwent catheter ablation of tachyarrhythmias. Patients equipped a wearable electrode and a lead CM5 of Holter ECG simultaneously, and total heart beats, maximum heart rate (HR), mean HR, minimum HR, detections of arrhythmias, such as atrial fibrillation, non-sustained ventricular tachycardia, and premature ventricular contractions (Lown's grade >II), were compared between the two methods using a Holter ECG analysis software.<h4>Results</h4>Median recording time of ECG by wearable electrodes was 12.6 hours. Strong correlations between the two methods were observed in total heart beats (R = 0.999, P <0.001), maximum HR (R = 0.997, P <0.001), mean HR (R = 0.999, P <0.001), minimum HR (R = 0.989, P <0.001) and QRS duration (R = 0.900, P <0.001). Bland-Altman analysis showed excellent concordance between each parameter measured by two methods. In addition, the detection of atrial fibrillation (nine events), non-sustained ventricular tachycardia (two events), and premature ventricular contractions of Lown's grade >II (five events) were concordant in two methods. In addition, there were no significant difference in parameters of time-domain and frequency-domain analyses of heart rate variability between the two methods.<h4>Conclusions</h4>The usefulness of a novel electrode embedded in an undershirt is equivalent to that of a Holter ECG in monitoring the ECG and detection of arrythmias.
first_indexed 2024-04-12T19:23:15Z
format Article
id doaj.art-d05719e418a940d2bb28bfbc52a570e0
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-04-12T19:23:15Z
publishDate 2022-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-d05719e418a940d2bb28bfbc52a570e02022-12-22T03:19:33ZengPublic Library of Science (PLoS)PLoS ONE1932-62032022-01-01178e027354110.1371/journal.pone.0273541Utility of a novel wearable electrode embedded in an undershirt for electrocardiogram monitoring and detection of arrhythmias.Kazuaki AmamiAkiomi YoshihisaYuko HorikoshiShinya YamadaTakeshi NehashiNaoko HijiokaMinoru NoderaTakashi KaneshiroTetsuro YokokawaTomofumi MisakaYasuchika Takeishi<h4>Background</h4>A 12-lead electrocardiogram (ECG) and Holter ECG have been established as gold standards for detection of arrhythmias. Recently, wearable ECG monitoring devices have been available. Our purpose of the present study was to investigate whether a novel wearable electrode embedded in an undershirt is useful for ECG monitoring and detection of arrhythmias.<h4>Methods</h4>We studied 31 consecutive hospitalized patients who underwent catheter ablation of tachyarrhythmias. Patients equipped a wearable electrode and a lead CM5 of Holter ECG simultaneously, and total heart beats, maximum heart rate (HR), mean HR, minimum HR, detections of arrhythmias, such as atrial fibrillation, non-sustained ventricular tachycardia, and premature ventricular contractions (Lown's grade >II), were compared between the two methods using a Holter ECG analysis software.<h4>Results</h4>Median recording time of ECG by wearable electrodes was 12.6 hours. Strong correlations between the two methods were observed in total heart beats (R = 0.999, P <0.001), maximum HR (R = 0.997, P <0.001), mean HR (R = 0.999, P <0.001), minimum HR (R = 0.989, P <0.001) and QRS duration (R = 0.900, P <0.001). Bland-Altman analysis showed excellent concordance between each parameter measured by two methods. In addition, the detection of atrial fibrillation (nine events), non-sustained ventricular tachycardia (two events), and premature ventricular contractions of Lown's grade >II (five events) were concordant in two methods. In addition, there were no significant difference in parameters of time-domain and frequency-domain analyses of heart rate variability between the two methods.<h4>Conclusions</h4>The usefulness of a novel electrode embedded in an undershirt is equivalent to that of a Holter ECG in monitoring the ECG and detection of arrythmias.https://doi.org/10.1371/journal.pone.0273541
spellingShingle Kazuaki Amami
Akiomi Yoshihisa
Yuko Horikoshi
Shinya Yamada
Takeshi Nehashi
Naoko Hijioka
Minoru Nodera
Takashi Kaneshiro
Tetsuro Yokokawa
Tomofumi Misaka
Yasuchika Takeishi
Utility of a novel wearable electrode embedded in an undershirt for electrocardiogram monitoring and detection of arrhythmias.
PLoS ONE
title Utility of a novel wearable electrode embedded in an undershirt for electrocardiogram monitoring and detection of arrhythmias.
title_full Utility of a novel wearable electrode embedded in an undershirt for electrocardiogram monitoring and detection of arrhythmias.
title_fullStr Utility of a novel wearable electrode embedded in an undershirt for electrocardiogram monitoring and detection of arrhythmias.
title_full_unstemmed Utility of a novel wearable electrode embedded in an undershirt for electrocardiogram monitoring and detection of arrhythmias.
title_short Utility of a novel wearable electrode embedded in an undershirt for electrocardiogram monitoring and detection of arrhythmias.
title_sort utility of a novel wearable electrode embedded in an undershirt for electrocardiogram monitoring and detection of arrhythmias
url https://doi.org/10.1371/journal.pone.0273541
work_keys_str_mv AT kazuakiamami utilityofanovelwearableelectrodeembeddedinanundershirtforelectrocardiogrammonitoringanddetectionofarrhythmias
AT akiomiyoshihisa utilityofanovelwearableelectrodeembeddedinanundershirtforelectrocardiogrammonitoringanddetectionofarrhythmias
AT yukohorikoshi utilityofanovelwearableelectrodeembeddedinanundershirtforelectrocardiogrammonitoringanddetectionofarrhythmias
AT shinyayamada utilityofanovelwearableelectrodeembeddedinanundershirtforelectrocardiogrammonitoringanddetectionofarrhythmias
AT takeshinehashi utilityofanovelwearableelectrodeembeddedinanundershirtforelectrocardiogrammonitoringanddetectionofarrhythmias
AT naokohijioka utilityofanovelwearableelectrodeembeddedinanundershirtforelectrocardiogrammonitoringanddetectionofarrhythmias
AT minorunodera utilityofanovelwearableelectrodeembeddedinanundershirtforelectrocardiogrammonitoringanddetectionofarrhythmias
AT takashikaneshiro utilityofanovelwearableelectrodeembeddedinanundershirtforelectrocardiogrammonitoringanddetectionofarrhythmias
AT tetsuroyokokawa utilityofanovelwearableelectrodeembeddedinanundershirtforelectrocardiogrammonitoringanddetectionofarrhythmias
AT tomofumimisaka utilityofanovelwearableelectrodeembeddedinanundershirtforelectrocardiogrammonitoringanddetectionofarrhythmias
AT yasuchikatakeishi utilityofanovelwearableelectrodeembeddedinanundershirtforelectrocardiogrammonitoringanddetectionofarrhythmias