Evaluation of thyromental distance versus tongue width versus weight-based method for size determination of laryngeal mask airway in adults

Background: Supraglottic airway devices (SGD) are indispensable for airway management. The successful placement of the laryngeal mask airway (LMA) supreme largely depends on the right size selection. Aims and Objectives: The study was undertaken to compare three LMA supreme insertion methods in s...

Full description

Bibliographic Details
Main Authors: Shalini Jain, Priyanka Joshi, K K Arora
Format: Article
Language:English
Published: Manipal College of Medical Sciences, Pokhara 2023-09-01
Series:Asian Journal of Medical Sciences
Subjects:
Online Access:https://www.nepjol.info/index.php/AJMS/article/view/54148
_version_ 1797727881476964352
author Shalini Jain
Priyanka Joshi
K K Arora
author_facet Shalini Jain
Priyanka Joshi
K K Arora
author_sort Shalini Jain
collection DOAJ
description Background: Supraglottic airway devices (SGD) are indispensable for airway management. The successful placement of the laryngeal mask airway (LMA) supreme largely depends on the right size selection. Aims and Objectives: The study was undertaken to compare three LMA supreme insertion methods in short elective surgeries under general anesthesia. Materials and Methods: Atotal of 90 American Society of Anesthesiologists I and II patients (either gender, 18–55 years, Mallampati grade I and II) undergoing short surgeries were randomized into three equal groups (n=30 in each). Insertion of LMA was done after an adequate depth of anesthesia for jaw relaxation (Young’s criteria). The efficacy of controlled ventilation through LMA by each method, success rate, ease of insertion, insertion time, additional induction dose (propofol) required during insertion, hemodynamic stability (baseline vitals and 10 min after insertion), and adverse events after LMA removal were evaluated between groups. Results: Better ventilation (tidal volume at 10 cmH2O) was observed in the thyromental group (448±35) than in tongue width (440±46) and weight-based (409±33) groups. Minimum additional propofol requirement during insertion was in thyromental distance group. Thyromental distance group had the most easy LMA insertions (70%) with minimum insertion time (10±4) and minimum additional propofol requirement during insertion (P<0.05) than other groups. Overall hemodynamic stability and incidence of adverse events were comparable. Conclusion: Thyromental distance may be an alternative attractive choice for size determination of LMA supreme in female adults with normal airway anatomy in comparison to tongue width and conventional body weight-based methods.
first_indexed 2024-03-12T11:05:54Z
format Article
id doaj.art-d05bf80235b245dd8179f7260e0a3b60
institution Directory Open Access Journal
issn 2467-9100
2091-0576
language English
last_indexed 2024-03-12T11:05:54Z
publishDate 2023-09-01
publisher Manipal College of Medical Sciences, Pokhara
record_format Article
series Asian Journal of Medical Sciences
spelling doaj.art-d05bf80235b245dd8179f7260e0a3b602023-09-02T04:03:53ZengManipal College of Medical Sciences, PokharaAsian Journal of Medical Sciences2467-91002091-05762023-09-011496975https://doi.org/10.3126/ajms.v14i9.54148Evaluation of thyromental distance versus tongue width versus weight-based method for size determination of laryngeal mask airway in adultsShalini Jain 0https://orcid.org/0000-0001-6702-9666Priyanka Joshi 1https://orcid.org/0009-0009-1732-5454K K Arora 2https://orcid.org/0000-0002-7376-4322Professor, Department of Anaesthesiology, Mahatma Gandhi Medical College, Indore, Madhya Pradesh, India Postgraduate Resident, Department of Anaesthesiology, Mahatma Gandhi Medical College, Indore, Madhya Pradesh, India Professor and Head, Department of Anaesthesiology, Mahatma Gandhi Medical College, Indore, Madhya Pradesh, India Background: Supraglottic airway devices (SGD) are indispensable for airway management. The successful placement of the laryngeal mask airway (LMA) supreme largely depends on the right size selection. Aims and Objectives: The study was undertaken to compare three LMA supreme insertion methods in short elective surgeries under general anesthesia. Materials and Methods: Atotal of 90 American Society of Anesthesiologists I and II patients (either gender, 18–55 years, Mallampati grade I and II) undergoing short surgeries were randomized into three equal groups (n=30 in each). Insertion of LMA was done after an adequate depth of anesthesia for jaw relaxation (Young’s criteria). The efficacy of controlled ventilation through LMA by each method, success rate, ease of insertion, insertion time, additional induction dose (propofol) required during insertion, hemodynamic stability (baseline vitals and 10 min after insertion), and adverse events after LMA removal were evaluated between groups. Results: Better ventilation (tidal volume at 10 cmH2O) was observed in the thyromental group (448±35) than in tongue width (440±46) and weight-based (409±33) groups. Minimum additional propofol requirement during insertion was in thyromental distance group. Thyromental distance group had the most easy LMA insertions (70%) with minimum insertion time (10±4) and minimum additional propofol requirement during insertion (P<0.05) than other groups. Overall hemodynamic stability and incidence of adverse events were comparable. Conclusion: Thyromental distance may be an alternative attractive choice for size determination of LMA supreme in female adults with normal airway anatomy in comparison to tongue width and conventional body weight-based methods.https://www.nepjol.info/index.php/AJMS/article/view/54148laryngeal mask airway; anesthesia; hemodynamic; ventilation; airway; thyromental distance; tongue width; body weight
spellingShingle Shalini Jain
Priyanka Joshi
K K Arora
Evaluation of thyromental distance versus tongue width versus weight-based method for size determination of laryngeal mask airway in adults
Asian Journal of Medical Sciences
laryngeal mask airway; anesthesia; hemodynamic; ventilation; airway; thyromental distance; tongue width; body weight
title Evaluation of thyromental distance versus tongue width versus weight-based method for size determination of laryngeal mask airway in adults
title_full Evaluation of thyromental distance versus tongue width versus weight-based method for size determination of laryngeal mask airway in adults
title_fullStr Evaluation of thyromental distance versus tongue width versus weight-based method for size determination of laryngeal mask airway in adults
title_full_unstemmed Evaluation of thyromental distance versus tongue width versus weight-based method for size determination of laryngeal mask airway in adults
title_short Evaluation of thyromental distance versus tongue width versus weight-based method for size determination of laryngeal mask airway in adults
title_sort evaluation of thyromental distance versus tongue width versus weight based method for size determination of laryngeal mask airway in adults
topic laryngeal mask airway; anesthesia; hemodynamic; ventilation; airway; thyromental distance; tongue width; body weight
url https://www.nepjol.info/index.php/AJMS/article/view/54148
work_keys_str_mv AT shalinijain evaluationofthyromentaldistanceversustonguewidthversusweightbasedmethodforsizedeterminationoflaryngealmaskairwayinadults
AT priyankajoshi evaluationofthyromentaldistanceversustonguewidthversusweightbasedmethodforsizedeterminationoflaryngealmaskairwayinadults
AT kkarora evaluationofthyromentaldistanceversustonguewidthversusweightbasedmethodforsizedeterminationoflaryngealmaskairwayinadults