Optimization of rwanda power system protection in power blackouts and cascading events

Abstract Rwanda's power system security is the most important in optimization of grid frequency to prevent power blackouts caused by load disturbances and power imbalances. To manually stabilize and restore network frequency, a tuned PID (Proportional, Integral, and Derivative) controller was u...

Full description

Bibliographic Details
Main Authors: Boniface Ntambara, Ritha Umuhoza
Format: Article
Language:English
Published: Springer 2022-10-01
Series:SN Applied Sciences
Subjects:
Online Access:https://doi.org/10.1007/s42452-022-05188-5
_version_ 1817984031885623296
author Boniface Ntambara
Ritha Umuhoza
author_facet Boniface Ntambara
Ritha Umuhoza
author_sort Boniface Ntambara
collection DOAJ
description Abstract Rwanda's power system security is the most important in optimization of grid frequency to prevent power blackouts caused by load disturbances and power imbalances. To manually stabilize and restore network frequency, a tuned PID (Proportional, Integral, and Derivative) controller was used, but it was inefficient and unreliable. The objective of this article is to develop a system that can be used to balance generation—demand powers during power outages by alleviating grid frequency in load disturbance cascaded events. By balancing power generation and demand, the balanced steady-state approach was proposed and developed to restore and optimize grid frequency to its normal state. This technique used PID-Power System Automatic Stabilization (PID-PSAS) technique based on load frequency control. The load disturbances of ± 20%, ± 10%, and ± 5% of a 250 MW power load were considered. MATLAB/Simulink was utilized to model and simulate the Rwanda power and controller systems. The results showed that the frequency responses of single and two area western and northern grids were reduced to $${13*10}^{-5}$$ 13 ∗ 10 - 5 Hz, $${15*10}^{-6}$$ 15 ∗ 10 - 6 Hz, and 0.251 s for overshoot, steady-state error, and settling time respectively. The proposed control system performance of 99.86% success rate was achieved and compared with the current control techniques of 70.6% performance rate. A stable frequency was observed at any disturbances and more than 300 megawatt losses were mitigated. Finally, the developed control technique rapidly stabilize the frequency and balance the generation-demand powers after 0.251 s. Future works have to focus on 0 Hz of steady state errors using cyber-physical power optimization systems. Article Highlights 1. The steadiness of connected loads and power utility supply 2. Reduction of frequency instability and stead-state values 3. Prevention and mitigation of power blackouts and power interruptions
first_indexed 2024-04-13T23:40:12Z
format Article
id doaj.art-d0846057e050481c8dbbc21c84d149f2
institution Directory Open Access Journal
issn 2523-3963
2523-3971
language English
last_indexed 2024-04-13T23:40:12Z
publishDate 2022-10-01
publisher Springer
record_format Article
series SN Applied Sciences
spelling doaj.art-d0846057e050481c8dbbc21c84d149f22022-12-22T02:24:33ZengSpringerSN Applied Sciences2523-39632523-39712022-10-0141111210.1007/s42452-022-05188-5Optimization of rwanda power system protection in power blackouts and cascading eventsBoniface Ntambara0Ritha Umuhoza1Department of Manufacturing, Industrial and Textile Engineering, Moi UniversitySchool of Computational and Communication Science and Engineering, The Nelson Mandela African Institution of Science and TechnologyAbstract Rwanda's power system security is the most important in optimization of grid frequency to prevent power blackouts caused by load disturbances and power imbalances. To manually stabilize and restore network frequency, a tuned PID (Proportional, Integral, and Derivative) controller was used, but it was inefficient and unreliable. The objective of this article is to develop a system that can be used to balance generation—demand powers during power outages by alleviating grid frequency in load disturbance cascaded events. By balancing power generation and demand, the balanced steady-state approach was proposed and developed to restore and optimize grid frequency to its normal state. This technique used PID-Power System Automatic Stabilization (PID-PSAS) technique based on load frequency control. The load disturbances of ± 20%, ± 10%, and ± 5% of a 250 MW power load were considered. MATLAB/Simulink was utilized to model and simulate the Rwanda power and controller systems. The results showed that the frequency responses of single and two area western and northern grids were reduced to $${13*10}^{-5}$$ 13 ∗ 10 - 5 Hz, $${15*10}^{-6}$$ 15 ∗ 10 - 6 Hz, and 0.251 s for overshoot, steady-state error, and settling time respectively. The proposed control system performance of 99.86% success rate was achieved and compared with the current control techniques of 70.6% performance rate. A stable frequency was observed at any disturbances and more than 300 megawatt losses were mitigated. Finally, the developed control technique rapidly stabilize the frequency and balance the generation-demand powers after 0.251 s. Future works have to focus on 0 Hz of steady state errors using cyber-physical power optimization systems. Article Highlights 1. The steadiness of connected loads and power utility supply 2. Reduction of frequency instability and stead-state values 3. Prevention and mitigation of power blackouts and power interruptionshttps://doi.org/10.1007/s42452-022-05188-5PID-PSAS controllerPower system automationFrequency load controlPower system stabilityMATLAB/SimulinkPower blackouts
spellingShingle Boniface Ntambara
Ritha Umuhoza
Optimization of rwanda power system protection in power blackouts and cascading events
SN Applied Sciences
PID-PSAS controller
Power system automation
Frequency load control
Power system stability
MATLAB/Simulink
Power blackouts
title Optimization of rwanda power system protection in power blackouts and cascading events
title_full Optimization of rwanda power system protection in power blackouts and cascading events
title_fullStr Optimization of rwanda power system protection in power blackouts and cascading events
title_full_unstemmed Optimization of rwanda power system protection in power blackouts and cascading events
title_short Optimization of rwanda power system protection in power blackouts and cascading events
title_sort optimization of rwanda power system protection in power blackouts and cascading events
topic PID-PSAS controller
Power system automation
Frequency load control
Power system stability
MATLAB/Simulink
Power blackouts
url https://doi.org/10.1007/s42452-022-05188-5
work_keys_str_mv AT bonifacentambara optimizationofrwandapowersystemprotectioninpowerblackoutsandcascadingevents
AT rithaumuhoza optimizationofrwandapowersystemprotectioninpowerblackoutsandcascadingevents