Behavioral changes to detect estrus using ear-sensor accelerometer compared to in-line milk progesterone in a commercial dairy herd

The first objective of this study was to compare behavioral and ear temperature changes using accelerometer ear tags (CowManager system; Sensor) during the declining progesterone (P4) phase (expected estrus) and the luteal phase determined using in-line milk P4 analysis (Herd Navigator system; HNS)....

Full description

Bibliographic Details
Main Authors: Hector J. Perez Marquez, Divakar J. Ambrose, Clover J. Bench
Format: Article
Language:English
Published: Frontiers Media S.A. 2023-08-01
Series:Frontiers in Animal Science
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fanim.2023.1149085/full
_version_ 1797755374252589056
author Hector J. Perez Marquez
Divakar J. Ambrose
Clover J. Bench
author_facet Hector J. Perez Marquez
Divakar J. Ambrose
Clover J. Bench
author_sort Hector J. Perez Marquez
collection DOAJ
description The first objective of this study was to compare behavioral and ear temperature changes using accelerometer ear tags (CowManager system; Sensor) during the declining progesterone (P4) phase (expected estrus) and the luteal phase determined using in-line milk P4 analysis (Herd Navigator system; HNS). The second objective was to evaluate the accuracy of each Sensor metric to detect estrus compared to HNS in a commercial dairy herd. Forty-six cows (23 young [1 to 2 lactations] and 23 mature [3 to 6 lactations]) at 20 days in milk (DIM) were fitted with Sensor tags, and P4 profiles measured via HNS until 90 DIM. Sensor metrics analyzed were Resting, Ruminating, Eating, Active, High-Active, and ear temperature (Etemp). The day of milk P4 decline below the 5 ng/mL threshold in the HNS was designated as d -1 (LSM ± SEM; 3.42 ± 0.08 ng/mL) and the day of expected estrus as d 0. Significant increases (LSM ± SEM) were observed at d 0 in Active (5.01 ± 0.14 min/h) and High-Active (8.70 ± 0.25 min/h) behavior responses as well as in Etemp (29.45 ± 0.08°C) compared with the luteal phase (Active: 4.46 ± 0.13 min/h; High-Active: 6.40 ± 0.22 min/h and Etemp: 28.69 ± 0.08°C). The greatest estrus detection accuracy (Youden Index [J: performance]) single metric was achieved using Etemp (0.24 J) followed by Resting (0.20 J) and High-Active (0.17 J) in all cows. Greater accuracy was observed in Young cows (Etemp: 0.44 J; Resting: 0.33 J; and High-Active: 0.25 J) than in Mature cows (Etemp: 0.09 J; Resting: 0.12 J; and High-Active: 0.13 J). Similarly, accuracy was greater when only healthy cows (cows with no postpartum health events) were compared (Etemp: 0.33 J; Resting: 0.31 J; High-Active: 0.20 J) to unhealthy cows (Etemp: 0.11 J; Resting: 0.02 J; High-Active: 0.02 J). The combination of behavior and Etemp metrics optimized the estrus detection accuracy in all the cows (0.30 J), Young (0.46 J), Mature (0.26 J), Healthy (0.45 J), and Unhealthy (0.11 J) cows compared to a single metric approach. Age and postpartum health affected the estrus detection accuracy using Sensor tags.
first_indexed 2024-03-12T17:46:57Z
format Article
id doaj.art-d0c79653b447437baf54c859f28400fa
institution Directory Open Access Journal
issn 2673-6225
language English
last_indexed 2024-03-12T17:46:57Z
publishDate 2023-08-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Animal Science
spelling doaj.art-d0c79653b447437baf54c859f28400fa2023-08-03T16:30:50ZengFrontiers Media S.A.Frontiers in Animal Science2673-62252023-08-01410.3389/fanim.2023.11490851149085Behavioral changes to detect estrus using ear-sensor accelerometer compared to in-line milk progesterone in a commercial dairy herdHector J. Perez MarquezDivakar J. AmbroseClover J. BenchThe first objective of this study was to compare behavioral and ear temperature changes using accelerometer ear tags (CowManager system; Sensor) during the declining progesterone (P4) phase (expected estrus) and the luteal phase determined using in-line milk P4 analysis (Herd Navigator system; HNS). The second objective was to evaluate the accuracy of each Sensor metric to detect estrus compared to HNS in a commercial dairy herd. Forty-six cows (23 young [1 to 2 lactations] and 23 mature [3 to 6 lactations]) at 20 days in milk (DIM) were fitted with Sensor tags, and P4 profiles measured via HNS until 90 DIM. Sensor metrics analyzed were Resting, Ruminating, Eating, Active, High-Active, and ear temperature (Etemp). The day of milk P4 decline below the 5 ng/mL threshold in the HNS was designated as d -1 (LSM ± SEM; 3.42 ± 0.08 ng/mL) and the day of expected estrus as d 0. Significant increases (LSM ± SEM) were observed at d 0 in Active (5.01 ± 0.14 min/h) and High-Active (8.70 ± 0.25 min/h) behavior responses as well as in Etemp (29.45 ± 0.08°C) compared with the luteal phase (Active: 4.46 ± 0.13 min/h; High-Active: 6.40 ± 0.22 min/h and Etemp: 28.69 ± 0.08°C). The greatest estrus detection accuracy (Youden Index [J: performance]) single metric was achieved using Etemp (0.24 J) followed by Resting (0.20 J) and High-Active (0.17 J) in all cows. Greater accuracy was observed in Young cows (Etemp: 0.44 J; Resting: 0.33 J; and High-Active: 0.25 J) than in Mature cows (Etemp: 0.09 J; Resting: 0.12 J; and High-Active: 0.13 J). Similarly, accuracy was greater when only healthy cows (cows with no postpartum health events) were compared (Etemp: 0.33 J; Resting: 0.31 J; High-Active: 0.20 J) to unhealthy cows (Etemp: 0.11 J; Resting: 0.02 J; High-Active: 0.02 J). The combination of behavior and Etemp metrics optimized the estrus detection accuracy in all the cows (0.30 J), Young (0.46 J), Mature (0.26 J), Healthy (0.45 J), and Unhealthy (0.11 J) cows compared to a single metric approach. Age and postpartum health affected the estrus detection accuracy using Sensor tags.https://www.frontiersin.org/articles/10.3389/fanim.2023.1149085/fullbio-sensorsestrus detectionactivityear-temperaturedairy cattleestrus-behavior
spellingShingle Hector J. Perez Marquez
Divakar J. Ambrose
Clover J. Bench
Behavioral changes to detect estrus using ear-sensor accelerometer compared to in-line milk progesterone in a commercial dairy herd
Frontiers in Animal Science
bio-sensors
estrus detection
activity
ear-temperature
dairy cattle
estrus-behavior
title Behavioral changes to detect estrus using ear-sensor accelerometer compared to in-line milk progesterone in a commercial dairy herd
title_full Behavioral changes to detect estrus using ear-sensor accelerometer compared to in-line milk progesterone in a commercial dairy herd
title_fullStr Behavioral changes to detect estrus using ear-sensor accelerometer compared to in-line milk progesterone in a commercial dairy herd
title_full_unstemmed Behavioral changes to detect estrus using ear-sensor accelerometer compared to in-line milk progesterone in a commercial dairy herd
title_short Behavioral changes to detect estrus using ear-sensor accelerometer compared to in-line milk progesterone in a commercial dairy herd
title_sort behavioral changes to detect estrus using ear sensor accelerometer compared to in line milk progesterone in a commercial dairy herd
topic bio-sensors
estrus detection
activity
ear-temperature
dairy cattle
estrus-behavior
url https://www.frontiersin.org/articles/10.3389/fanim.2023.1149085/full
work_keys_str_mv AT hectorjperezmarquez behavioralchangestodetectestrususingearsensoraccelerometercomparedtoinlinemilkprogesteroneinacommercialdairyherd
AT divakarjambrose behavioralchangestodetectestrususingearsensoraccelerometercomparedtoinlinemilkprogesteroneinacommercialdairyherd
AT cloverjbench behavioralchangestodetectestrususingearsensoraccelerometercomparedtoinlinemilkprogesteroneinacommercialdairyherd