A Comparison of Heart Pulsations Provided by Forcecardiography and Double Integration of Seismocardiogram

Seismocardiography (SCG) is largely regarded as the state-of-the-art technique for continuous, long-term monitoring of cardiac mechanical activity in wearable applications. SCG signals are acquired via small, lightweight accelerometers fixed on the chest. They provide timings of important cardiac ev...

Full description

Bibliographic Details
Main Authors: Emilio Andreozzi, Jessica Centracchio, Daniele Esposito, Paolo Bifulco
Format: Article
Language:English
Published: MDPI AG 2022-04-01
Series:Bioengineering
Subjects:
Online Access:https://www.mdpi.com/2306-5354/9/4/167
_version_ 1797436916931493888
author Emilio Andreozzi
Jessica Centracchio
Daniele Esposito
Paolo Bifulco
author_facet Emilio Andreozzi
Jessica Centracchio
Daniele Esposito
Paolo Bifulco
author_sort Emilio Andreozzi
collection DOAJ
description Seismocardiography (SCG) is largely regarded as the state-of-the-art technique for continuous, long-term monitoring of cardiac mechanical activity in wearable applications. SCG signals are acquired via small, lightweight accelerometers fixed on the chest. They provide timings of important cardiac events, such as heart valves openings and closures, thus allowing the estimation of cardiac time intervals of clinical relevance. Forcecardiography (FCG) is a novel technique that records the cardiac-induced vibrations of the chest wall by means of specific force sensors, which proved capable of monitoring respiration, heart sounds and infrasonic cardiac vibrations, simultaneously from a single contact point on the chest. A specific infrasonic component captures the heart walls displacements and looks very similar to the Apexcardiogram. This low-frequency component is not visible in SCG recordings, nor it can be extracted by simple filtering. In this study, a feasible way to extract this information from SCG signals is presented. The proposed approach is based on double integration of SCG. Numerical double integration is usually very prone to large errors, therefore a specific numerical procedure was devised. This procedure yields a new displacement signal (DSCG) that features a low-frequency component (LF-DSCG) very similar to that of the FCG (LF-FCG). Experimental tests were carried out using an FCG sensor and an off-the-shelf accelerometer firmly attached to each other and placed onto the precordial region. Simultaneous recordings were acquired from both sensors, together with an electrocardiogram lead (used as a reference). Quantitative morphological comparison confirmed the high similarity between LF-FCG and LF-DSCG (normalized cross-correlation index >0.9). Statistical analyses suggested that LF-DSCG, although achieving a fair sensitivity in heartbeat detection (about 90%), has not a very high consistency within the cardiac cycle, leading to inaccuracies in inter-beat intervals estimation. Future experiments with high-performance accelerometers and improved processing methods are envisioned to investigate the potential enhancement of the accuracy and reliability of the proposed method.
first_indexed 2024-03-09T11:09:28Z
format Article
id doaj.art-d0ce8031768941f0bd67d244ba08d70c
institution Directory Open Access Journal
issn 2306-5354
language English
last_indexed 2024-03-09T11:09:28Z
publishDate 2022-04-01
publisher MDPI AG
record_format Article
series Bioengineering
spelling doaj.art-d0ce8031768941f0bd67d244ba08d70c2023-12-01T00:49:34ZengMDPI AGBioengineering2306-53542022-04-019416710.3390/bioengineering9040167A Comparison of Heart Pulsations Provided by Forcecardiography and Double Integration of SeismocardiogramEmilio Andreozzi0Jessica Centracchio1Daniele Esposito2Paolo Bifulco3Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21, 80125 Napoli, ItalyDepartment of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21, 80125 Napoli, ItalyDepartment of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21, 80125 Napoli, ItalyDepartment of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21, 80125 Napoli, ItalySeismocardiography (SCG) is largely regarded as the state-of-the-art technique for continuous, long-term monitoring of cardiac mechanical activity in wearable applications. SCG signals are acquired via small, lightweight accelerometers fixed on the chest. They provide timings of important cardiac events, such as heart valves openings and closures, thus allowing the estimation of cardiac time intervals of clinical relevance. Forcecardiography (FCG) is a novel technique that records the cardiac-induced vibrations of the chest wall by means of specific force sensors, which proved capable of monitoring respiration, heart sounds and infrasonic cardiac vibrations, simultaneously from a single contact point on the chest. A specific infrasonic component captures the heart walls displacements and looks very similar to the Apexcardiogram. This low-frequency component is not visible in SCG recordings, nor it can be extracted by simple filtering. In this study, a feasible way to extract this information from SCG signals is presented. The proposed approach is based on double integration of SCG. Numerical double integration is usually very prone to large errors, therefore a specific numerical procedure was devised. This procedure yields a new displacement signal (DSCG) that features a low-frequency component (LF-DSCG) very similar to that of the FCG (LF-FCG). Experimental tests were carried out using an FCG sensor and an off-the-shelf accelerometer firmly attached to each other and placed onto the precordial region. Simultaneous recordings were acquired from both sensors, together with an electrocardiogram lead (used as a reference). Quantitative morphological comparison confirmed the high similarity between LF-FCG and LF-DSCG (normalized cross-correlation index >0.9). Statistical analyses suggested that LF-DSCG, although achieving a fair sensitivity in heartbeat detection (about 90%), has not a very high consistency within the cardiac cycle, leading to inaccuracies in inter-beat intervals estimation. Future experiments with high-performance accelerometers and improved processing methods are envisioned to investigate the potential enhancement of the accuracy and reliability of the proposed method.https://www.mdpi.com/2306-5354/9/4/167ForcecardiographySeismocardiographyheart vibrationspiezoelectric sensoraccelerometercardiac monitoring
spellingShingle Emilio Andreozzi
Jessica Centracchio
Daniele Esposito
Paolo Bifulco
A Comparison of Heart Pulsations Provided by Forcecardiography and Double Integration of Seismocardiogram
Bioengineering
Forcecardiography
Seismocardiography
heart vibrations
piezoelectric sensor
accelerometer
cardiac monitoring
title A Comparison of Heart Pulsations Provided by Forcecardiography and Double Integration of Seismocardiogram
title_full A Comparison of Heart Pulsations Provided by Forcecardiography and Double Integration of Seismocardiogram
title_fullStr A Comparison of Heart Pulsations Provided by Forcecardiography and Double Integration of Seismocardiogram
title_full_unstemmed A Comparison of Heart Pulsations Provided by Forcecardiography and Double Integration of Seismocardiogram
title_short A Comparison of Heart Pulsations Provided by Forcecardiography and Double Integration of Seismocardiogram
title_sort comparison of heart pulsations provided by forcecardiography and double integration of seismocardiogram
topic Forcecardiography
Seismocardiography
heart vibrations
piezoelectric sensor
accelerometer
cardiac monitoring
url https://www.mdpi.com/2306-5354/9/4/167
work_keys_str_mv AT emilioandreozzi acomparisonofheartpulsationsprovidedbyforcecardiographyanddoubleintegrationofseismocardiogram
AT jessicacentracchio acomparisonofheartpulsationsprovidedbyforcecardiographyanddoubleintegrationofseismocardiogram
AT danieleesposito acomparisonofheartpulsationsprovidedbyforcecardiographyanddoubleintegrationofseismocardiogram
AT paolobifulco acomparisonofheartpulsationsprovidedbyforcecardiographyanddoubleintegrationofseismocardiogram
AT emilioandreozzi comparisonofheartpulsationsprovidedbyforcecardiographyanddoubleintegrationofseismocardiogram
AT jessicacentracchio comparisonofheartpulsationsprovidedbyforcecardiographyanddoubleintegrationofseismocardiogram
AT danieleesposito comparisonofheartpulsationsprovidedbyforcecardiographyanddoubleintegrationofseismocardiogram
AT paolobifulco comparisonofheartpulsationsprovidedbyforcecardiographyanddoubleintegrationofseismocardiogram