Comparison of accuracy of activity measurements with wearable activity trackers in wheelchair users: a preliminary evaluation

Background: Central nervous system diseases or injuries such as spinal cord injury (SCI) are often associated with a severe impairment of ambulatory function and result in wheelchair dependency. Typical long-term complications of wheelchair users include pressure injuries, spasticity, musculoskeleta...

Full description

Bibliographic Details
Main Authors: Benning, Nils-Hendrik, Knaup, Petra, Rupp, Rüdiger
Format: Article
Language:deu
Published: German Medical Science GMS Publishing House 2020-08-01
Series:GMS Medizinische Informatik, Biometrie und Epidemiologie
Subjects:
Online Access:http://www.egms.de/static/en/journals/mibe/2020-16/mibe000208.shtml
_version_ 1818841937482874880
author Benning, Nils-Hendrik
Knaup, Petra
Rupp, Rüdiger
author_facet Benning, Nils-Hendrik
Knaup, Petra
Rupp, Rüdiger
author_sort Benning, Nils-Hendrik
collection DOAJ
description Background: Central nervous system diseases or injuries such as spinal cord injury (SCI) are often associated with a severe impairment of ambulatory function and result in wheelchair dependency. Typical long-term complications of wheelchair users include pressure injuries, spasticity, musculoskeletal pain and psychological issues. It is hypothesized that the occurrence of these complications is related to the level of physical activity (PA). While a low level of PA often results in skin or cardiovascular problems, a very high PA level results in shoulder pain and muscular fatigue. However, current evidence for this hypothesis is based on qualitative data from patient interviews. To investigate the relation between PA and health complications in a more objective manner, we propose the use of wearable activity trackers. As a first step, accuracy of common trackers – Apple Watch Series 4 and Fitbit Flex 2 – for quantification of wheelchair pushes was determined. For the Apple Watch, two different conditions are compared: out of the box usage and usage with GPS calibration.Methods: We used a 200 m outdoor test course. Healthy subjects were asked to propel with a wheelchair along the course while ground truth was captured by manually counting the wheelchair pushes. This procedure was conducted twice: once with the GPS-calibrated Apple Watch and Flex 2 in parallel and once with the non-calibrated Apple Watch. We analyzed the reproducibility of the ground truth measurement method by calculating the interrater reliability for two rater roles. To compare for accuracy of the activity trackers, we calculated differences between trackers and ground truth and analyzed them in Bland-Altman plots. To conclude on the need for GPS calibration of the Apple Watch in future studies, we did an equivalence test.Results: Twenty subjects without motor impairments participated in driving the test course. We found a reproducibility of the ground truth measurement of ICC(2,1)=0.981 (CI=0.96<ICC<0.99). The percentage of error for the calibrated Apple Watch is 13.9%, for the uncalibrated Apple Watch 22.8% and for the Flex 2 59.7%. Bland-Altman plots indicate a tendency for a higher error for test series with a higher number of pushes for the Flex 2. The equivalence test was significant for the defined equivalence boundaries of 15%.Conclusions: The ICC of the ground truth measurements indicates a high reproducibility of manual counting. Percentages of error show the highest accuracy for the calibrated Apple Watch. However, the results of the significant equivalence test suggest that the Apple Watch can be used without complex and time-consuming calibration. Due to extremely high error, PA tracking by Fitbit Flex 2 cannot be recommended for wheelchair users. This work is intended to serve as a basis for a future evaluation study of an activity tracker, for which we recommend using the uncalibrated Apple Watch in chronic wheelchair users. The evaluated tracker is intended to be used in a larger healthcare registry for follow-up of SCI patients.
first_indexed 2024-12-19T04:34:01Z
format Article
id doaj.art-d0d204d9ff014ddd88459eb63040bb4a
institution Directory Open Access Journal
issn 1860-9171
language deu
last_indexed 2024-12-19T04:34:01Z
publishDate 2020-08-01
publisher German Medical Science GMS Publishing House
record_format Article
series GMS Medizinische Informatik, Biometrie und Epidemiologie
spelling doaj.art-d0d204d9ff014ddd88459eb63040bb4a2022-12-21T20:35:48ZdeuGerman Medical Science GMS Publishing HouseGMS Medizinische Informatik, Biometrie und Epidemiologie1860-91712020-08-01162Doc0510.3205/mibe000208Comparison of accuracy of activity measurements with wearable activity trackers in wheelchair users: a preliminary evaluationBenning, Nils-Hendrik0Knaup, Petra1Rupp, Rüdiger2Institute of Medical Biometry and Informatics, Heidelberg University, Heidelberg, GermanyInstitute of Medical Biometry and Informatics, Heidelberg University, Heidelberg, GermanySpinal Cord Injury Center, Heidelberg University Hospital, Heidelberg, GermanyBackground: Central nervous system diseases or injuries such as spinal cord injury (SCI) are often associated with a severe impairment of ambulatory function and result in wheelchair dependency. Typical long-term complications of wheelchair users include pressure injuries, spasticity, musculoskeletal pain and psychological issues. It is hypothesized that the occurrence of these complications is related to the level of physical activity (PA). While a low level of PA often results in skin or cardiovascular problems, a very high PA level results in shoulder pain and muscular fatigue. However, current evidence for this hypothesis is based on qualitative data from patient interviews. To investigate the relation between PA and health complications in a more objective manner, we propose the use of wearable activity trackers. As a first step, accuracy of common trackers – Apple Watch Series 4 and Fitbit Flex 2 – for quantification of wheelchair pushes was determined. For the Apple Watch, two different conditions are compared: out of the box usage and usage with GPS calibration.Methods: We used a 200 m outdoor test course. Healthy subjects were asked to propel with a wheelchair along the course while ground truth was captured by manually counting the wheelchair pushes. This procedure was conducted twice: once with the GPS-calibrated Apple Watch and Flex 2 in parallel and once with the non-calibrated Apple Watch. We analyzed the reproducibility of the ground truth measurement method by calculating the interrater reliability for two rater roles. To compare for accuracy of the activity trackers, we calculated differences between trackers and ground truth and analyzed them in Bland-Altman plots. To conclude on the need for GPS calibration of the Apple Watch in future studies, we did an equivalence test.Results: Twenty subjects without motor impairments participated in driving the test course. We found a reproducibility of the ground truth measurement of ICC(2,1)=0.981 (CI=0.96<ICC<0.99). The percentage of error for the calibrated Apple Watch is 13.9%, for the uncalibrated Apple Watch 22.8% and for the Flex 2 59.7%. Bland-Altman plots indicate a tendency for a higher error for test series with a higher number of pushes for the Flex 2. The equivalence test was significant for the defined equivalence boundaries of 15%.Conclusions: The ICC of the ground truth measurements indicates a high reproducibility of manual counting. Percentages of error show the highest accuracy for the calibrated Apple Watch. However, the results of the significant equivalence test suggest that the Apple Watch can be used without complex and time-consuming calibration. Due to extremely high error, PA tracking by Fitbit Flex 2 cannot be recommended for wheelchair users. This work is intended to serve as a basis for a future evaluation study of an activity tracker, for which we recommend using the uncalibrated Apple Watch in chronic wheelchair users. The evaluated tracker is intended to be used in a larger healthcare registry for follow-up of SCI patients.http://www.egms.de/static/en/journals/mibe/2020-16/mibe000208.shtmlmedical informaticsfitness trackersphysical activitywheelchairsspinal cord injuries
spellingShingle Benning, Nils-Hendrik
Knaup, Petra
Rupp, Rüdiger
Comparison of accuracy of activity measurements with wearable activity trackers in wheelchair users: a preliminary evaluation
GMS Medizinische Informatik, Biometrie und Epidemiologie
medical informatics
fitness trackers
physical activity
wheelchairs
spinal cord injuries
title Comparison of accuracy of activity measurements with wearable activity trackers in wheelchair users: a preliminary evaluation
title_full Comparison of accuracy of activity measurements with wearable activity trackers in wheelchair users: a preliminary evaluation
title_fullStr Comparison of accuracy of activity measurements with wearable activity trackers in wheelchair users: a preliminary evaluation
title_full_unstemmed Comparison of accuracy of activity measurements with wearable activity trackers in wheelchair users: a preliminary evaluation
title_short Comparison of accuracy of activity measurements with wearable activity trackers in wheelchair users: a preliminary evaluation
title_sort comparison of accuracy of activity measurements with wearable activity trackers in wheelchair users a preliminary evaluation
topic medical informatics
fitness trackers
physical activity
wheelchairs
spinal cord injuries
url http://www.egms.de/static/en/journals/mibe/2020-16/mibe000208.shtml
work_keys_str_mv AT benningnilshendrik comparisonofaccuracyofactivitymeasurementswithwearableactivitytrackersinwheelchairusersapreliminaryevaluation
AT knauppetra comparisonofaccuracyofactivitymeasurementswithwearableactivitytrackersinwheelchairusersapreliminaryevaluation
AT rupprudiger comparisonofaccuracyofactivitymeasurementswithwearableactivitytrackersinwheelchairusersapreliminaryevaluation