Homogeneity Test on Collimators for Boron-Neutron Capture Therapy based on SNI 8506:2018
A serial homogeneity test based on Indonesian Standard SNI 8506:2018 were undertaken to investigate 12 manufactured collimators by using double wall single image radiography (DWSI) technique with an x-ray machine ranging from 120 to 150 kV. The standard stated that the film density should be measure...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Center for Development of Nuclear Informatics, National Nuclear Energy Agency (BATAN)
2023-08-01
|
Series: | Atom Indonesia |
Subjects: | |
Online Access: | https://aij.batan.go.id/index.php/aij/article/view/1277 |
_version_ | 1797730978554183680 |
---|---|
author | S. Santosa K. Khotimah H. Yasmine |
author_facet | S. Santosa K. Khotimah H. Yasmine |
author_sort | S. Santosa |
collection | DOAJ |
description | A serial homogeneity test based on Indonesian Standard SNI 8506:2018 were undertaken to investigate 12 manufactured collimators by using double wall single image radiography (DWSI) technique with an x-ray machine ranging from 120 to 150 kV. The standard stated that the film density should be measured on seven different points, and the result obtained must not exceed ± 0.05 from the average density. This paper outlines a testing work for the collimators, calculating the density on six different points in the film. Six different points were selected due to technical constrains of the collimator manufacturing and radiography capabilities of the selected laboratory. The results of film the density for the 12 collimators are: (1) 2.59; (2) 2.57; (3) 2.14; (4) 1.88; (5) 2.10; (6) 1.96; (7) 2.33; (8) 2.28; (9) 2.06; (10) 2.18; (11) 2.24; and (12) 2.33. The result shows that collimator-2 has the most homogenous density. This study concludes that established parameters and process are needed to manufacture the collimator for BNCT in achieving proper performance testing based on the standard. |
first_indexed | 2024-03-12T11:51:57Z |
format | Article |
id | doaj.art-d0e7f73b93ca4570b6930e589fc8c7c5 |
institution | Directory Open Access Journal |
issn | 0126-1568 |
language | English |
last_indexed | 2024-03-12T11:51:57Z |
publishDate | 2023-08-01 |
publisher | Center for Development of Nuclear Informatics, National Nuclear Energy Agency (BATAN) |
record_format | Article |
series | Atom Indonesia |
spelling | doaj.art-d0e7f73b93ca4570b6930e589fc8c7c52023-08-31T06:50:09ZengCenter for Development of Nuclear Informatics, National Nuclear Energy Agency (BATAN)Atom Indonesia0126-15682023-08-01129710110.55981/aij.2023.1277532Homogeneity Test on Collimators for Boron-Neutron Capture Therapy based on SNI 8506:2018S. Santosa0K. KhotimahH. YasmineBRINA serial homogeneity test based on Indonesian Standard SNI 8506:2018 were undertaken to investigate 12 manufactured collimators by using double wall single image radiography (DWSI) technique with an x-ray machine ranging from 120 to 150 kV. The standard stated that the film density should be measured on seven different points, and the result obtained must not exceed ± 0.05 from the average density. This paper outlines a testing work for the collimators, calculating the density on six different points in the film. Six different points were selected due to technical constrains of the collimator manufacturing and radiography capabilities of the selected laboratory. The results of film the density for the 12 collimators are: (1) 2.59; (2) 2.57; (3) 2.14; (4) 1.88; (5) 2.10; (6) 1.96; (7) 2.33; (8) 2.28; (9) 2.06; (10) 2.18; (11) 2.24; and (12) 2.33. The result shows that collimator-2 has the most homogenous density. This study concludes that established parameters and process are needed to manufacture the collimator for BNCT in achieving proper performance testing based on the standard.https://aij.batan.go.id/index.php/aij/article/view/1277boron-neutron capture therapyhomogeneity testneutron collimator |
spellingShingle | S. Santosa K. Khotimah H. Yasmine Homogeneity Test on Collimators for Boron-Neutron Capture Therapy based on SNI 8506:2018 Atom Indonesia boron-neutron capture therapy homogeneity test neutron collimator |
title | Homogeneity Test on Collimators for Boron-Neutron Capture Therapy based on SNI 8506:2018 |
title_full | Homogeneity Test on Collimators for Boron-Neutron Capture Therapy based on SNI 8506:2018 |
title_fullStr | Homogeneity Test on Collimators for Boron-Neutron Capture Therapy based on SNI 8506:2018 |
title_full_unstemmed | Homogeneity Test on Collimators for Boron-Neutron Capture Therapy based on SNI 8506:2018 |
title_short | Homogeneity Test on Collimators for Boron-Neutron Capture Therapy based on SNI 8506:2018 |
title_sort | homogeneity test on collimators for boron neutron capture therapy based on sni 8506 2018 |
topic | boron-neutron capture therapy homogeneity test neutron collimator |
url | https://aij.batan.go.id/index.php/aij/article/view/1277 |
work_keys_str_mv | AT ssantosa homogeneitytestoncollimatorsforboronneutroncapturetherapybasedonsni85062018 AT kkhotimah homogeneitytestoncollimatorsforboronneutroncapturetherapybasedonsni85062018 AT hyasmine homogeneitytestoncollimatorsforboronneutroncapturetherapybasedonsni85062018 |