Application of a Novel One-Side Cell Quartz Crystal Microbalance Immunosensor in the Determination of Alpha-Fetoprotein from Human Serum
The rapid and accurate detection of alpha-fetoprotein (AFP) levels is of great significance for the diagnosis and later treatment evaluation of liver cancer. In this study, a novel integrated quartz crystal microbalance (QCM) immunosensor based on the design to contact liquids on one side only was d...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2023-05-01
|
Series: | Diagnostics |
Subjects: | |
Online Access: | https://www.mdpi.com/2075-4418/13/9/1630 |
_version_ | 1797602797405863936 |
---|---|
author | Yan Chen Huashan Shi Bo Mu |
author_facet | Yan Chen Huashan Shi Bo Mu |
author_sort | Yan Chen |
collection | DOAJ |
description | The rapid and accurate detection of alpha-fetoprotein (AFP) levels is of great significance for the diagnosis and later treatment evaluation of liver cancer. In this study, a novel integrated quartz crystal microbalance (QCM) immunosensor based on the design to contact liquids on one side only was developed for the label-free detection of AFP. Anti-AFP mouse monoclonal antibodies were immobilized onto the upper electrode surface of the pre-treatment crystals using the staphylococcus aureus protein A. The AFP antigens in human serum were captured by specific surface-coated antibodies, and testing was carried out by monitoring the corresponding changes in frequency. The concentration range of the antigen detected was 13–760 ng/mL. The frequency characteristics of the process of antibody immobilization were investigated in detail, and high reproducibility of AFP antibody immobilization was achieved (standard deviation (SD) = 2.2 Hz). The developed QCM measurement system demonstrated a short test time (only 30 min), good reproducibility (the biological activity can still maintain more than 90% of the first test till it is reused five times), and accuracy as good as the one achieved with the radioimmunoassay (the maximum relative deviation = 4.8%). The designed QCM test system can easily and quickly detect AFP concentrations up to 760 ng/mL, indicating that the developed QCM assay is likely to lead to an alternative approach in large-scale screening for liver cancer in the near future. |
first_indexed | 2024-03-11T04:21:34Z |
format | Article |
id | doaj.art-d11c0ac7351e4658aa5f31373e5ff5b6 |
institution | Directory Open Access Journal |
issn | 2075-4418 |
language | English |
last_indexed | 2024-03-11T04:21:34Z |
publishDate | 2023-05-01 |
publisher | MDPI AG |
record_format | Article |
series | Diagnostics |
spelling | doaj.art-d11c0ac7351e4658aa5f31373e5ff5b62023-11-17T22:46:18ZengMDPI AGDiagnostics2075-44182023-05-01139163010.3390/diagnostics13091630Application of a Novel One-Side Cell Quartz Crystal Microbalance Immunosensor in the Determination of Alpha-Fetoprotein from Human SerumYan Chen0Huashan Shi1Bo Mu2School of Information Engineering, Southwest University of Science and Technology, Mianyang 621010, ChinaDepartment of Biological Therapy, West China Hospital, Sichuan University, Chengdu 610047, ChinaSchool of Basic Medical Sciences, North Sichuan Medical College, Nanchong 637100, ChinaThe rapid and accurate detection of alpha-fetoprotein (AFP) levels is of great significance for the diagnosis and later treatment evaluation of liver cancer. In this study, a novel integrated quartz crystal microbalance (QCM) immunosensor based on the design to contact liquids on one side only was developed for the label-free detection of AFP. Anti-AFP mouse monoclonal antibodies were immobilized onto the upper electrode surface of the pre-treatment crystals using the staphylococcus aureus protein A. The AFP antigens in human serum were captured by specific surface-coated antibodies, and testing was carried out by monitoring the corresponding changes in frequency. The concentration range of the antigen detected was 13–760 ng/mL. The frequency characteristics of the process of antibody immobilization were investigated in detail, and high reproducibility of AFP antibody immobilization was achieved (standard deviation (SD) = 2.2 Hz). The developed QCM measurement system demonstrated a short test time (only 30 min), good reproducibility (the biological activity can still maintain more than 90% of the first test till it is reused five times), and accuracy as good as the one achieved with the radioimmunoassay (the maximum relative deviation = 4.8%). The designed QCM test system can easily and quickly detect AFP concentrations up to 760 ng/mL, indicating that the developed QCM assay is likely to lead to an alternative approach in large-scale screening for liver cancer in the near future.https://www.mdpi.com/2075-4418/13/9/1630alpha-fetoprotein (AFP)quartz crystal microbalance (QCM)immunosensorhuman serum |
spellingShingle | Yan Chen Huashan Shi Bo Mu Application of a Novel One-Side Cell Quartz Crystal Microbalance Immunosensor in the Determination of Alpha-Fetoprotein from Human Serum Diagnostics alpha-fetoprotein (AFP) quartz crystal microbalance (QCM) immunosensor human serum |
title | Application of a Novel One-Side Cell Quartz Crystal Microbalance Immunosensor in the Determination of Alpha-Fetoprotein from Human Serum |
title_full | Application of a Novel One-Side Cell Quartz Crystal Microbalance Immunosensor in the Determination of Alpha-Fetoprotein from Human Serum |
title_fullStr | Application of a Novel One-Side Cell Quartz Crystal Microbalance Immunosensor in the Determination of Alpha-Fetoprotein from Human Serum |
title_full_unstemmed | Application of a Novel One-Side Cell Quartz Crystal Microbalance Immunosensor in the Determination of Alpha-Fetoprotein from Human Serum |
title_short | Application of a Novel One-Side Cell Quartz Crystal Microbalance Immunosensor in the Determination of Alpha-Fetoprotein from Human Serum |
title_sort | application of a novel one side cell quartz crystal microbalance immunosensor in the determination of alpha fetoprotein from human serum |
topic | alpha-fetoprotein (AFP) quartz crystal microbalance (QCM) immunosensor human serum |
url | https://www.mdpi.com/2075-4418/13/9/1630 |
work_keys_str_mv | AT yanchen applicationofanovelonesidecellquartzcrystalmicrobalanceimmunosensorinthedeterminationofalphafetoproteinfromhumanserum AT huashanshi applicationofanovelonesidecellquartzcrystalmicrobalanceimmunosensorinthedeterminationofalphafetoproteinfromhumanserum AT bomu applicationofanovelonesidecellquartzcrystalmicrobalanceimmunosensorinthedeterminationofalphafetoproteinfromhumanserum |