Multimodal Breast Phantoms for Microwave, Ultrasound, Mammography, Magnetic Resonance and Computed Tomography Imaging
The aim of this work was to develop multimodal anthropomorphic breast phantoms suitable for evaluating the imaging performance of a recently-introduced Microwave Imaging (MWI) technique in comparison to the established diagnostic imaging modalities of Magnetic Resonance Imaging (MRI), Ultrasound (US...
Main Authors: | , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-04-01
|
Series: | Sensors |
Subjects: | |
Online Access: | https://www.mdpi.com/1424-8220/20/8/2400 |
_version_ | 1797569806785839104 |
---|---|
author | Giuseppe Ruvio Raffaele Solimene Antonio Cuccaro Gaia Fiaschetti Andrew J. Fagan Sean Cournane Jennie Cooke Max J. Ammann Jorge Tobon Jacinta E. Browne |
author_facet | Giuseppe Ruvio Raffaele Solimene Antonio Cuccaro Gaia Fiaschetti Andrew J. Fagan Sean Cournane Jennie Cooke Max J. Ammann Jorge Tobon Jacinta E. Browne |
author_sort | Giuseppe Ruvio |
collection | DOAJ |
description | The aim of this work was to develop multimodal anthropomorphic breast phantoms suitable for evaluating the imaging performance of a recently-introduced Microwave Imaging (MWI) technique in comparison to the established diagnostic imaging modalities of Magnetic Resonance Imaging (MRI), Ultrasound (US), mammography and Computed Tomography (CT). MWI is an emerging technique with significant potential to supplement established imaging techniques to improve diagnostic confidence for breast cancer detection. To date, numerical simulations have been used to assess the different MWI scanning and image reconstruction algorithms in current use, while only a few clinical trials have been conducted. To bridge the gap between the numerical simulation environment and a more realistic diagnostic scenario, anthropomorphic phantoms which mimic breast tissues in terms of their heterogeneity, anatomy, morphology, and mechanical and dielectric characteristics, may be used. Key in this regard is achieving realism in the imaging appearance of the different healthy and pathologic tissue types for each of the modalities, taking into consideration the differing imaging and contrast mechanisms for each modality. Suitable phantoms can thus be used by radiologists to correlate image findings between the emerging MWI technique and the more familiar images generated by the conventional modalities. Two phantoms were developed in this study, representing difficult-to-image and easy-to-image patients: the former contained a complex boundary between the mammary fat and fibroglandular tissues, extracted from real patient MRI datasets, while the latter contained a simpler and less morphologically accurate interface. Both phantoms were otherwise identical, with tissue-mimicking materials (TMMs) developed to mimic skin, subcutaneous fat, fibroglandular tissue, tumor and pectoral muscle. The phantoms’ construction used non-toxic materials, and they were inexpensive and relatively easy to manufacture. Both phantoms were scanned using conventional modalities (MRI, US, mammography and CT) and a recently introduced MWI radar detection procedure called in-coherent Multiple Signal Classification (I-MUSIC). Clinically realistic artifact-free images of the anthropomorphic breast phantoms were obtained using the conventional imaging techniques as well as the emerging technique of MWI. |
first_indexed | 2024-03-10T20:16:46Z |
format | Article |
id | doaj.art-d14341c02eb54973bfb09eea28e000cd |
institution | Directory Open Access Journal |
issn | 1424-8220 |
language | English |
last_indexed | 2024-03-10T20:16:46Z |
publishDate | 2020-04-01 |
publisher | MDPI AG |
record_format | Article |
series | Sensors |
spelling | doaj.art-d14341c02eb54973bfb09eea28e000cd2023-11-19T22:30:43ZengMDPI AGSensors1424-82202020-04-01208240010.3390/s20082400Multimodal Breast Phantoms for Microwave, Ultrasound, Mammography, Magnetic Resonance and Computed Tomography ImagingGiuseppe Ruvio0Raffaele Solimene1Antonio Cuccaro2Gaia Fiaschetti3Andrew J. Fagan4Sean Cournane5Jennie Cooke6Max J. Ammann7Jorge Tobon8Jacinta E. Browne9School of Medicine, National University of Ireland Galway, Galway 8, IrelandDipartimento di Ingegneria, Università degli Studi della Campania Luigi Vanvitelli, 81031 Aversa, ItalyDipartimento di Ingegneria, Università degli Studi della Campania Luigi Vanvitelli, 81031 Aversa, ItalyDepartment of Information Engineering, Electronics, and Telecommunications, Sapienza University, 00185 Rome, ItalyDepartment of Radiology, Mayo Clinic, Rochester, MN 55905, USAMedical Physics and Bioengineering Department, St. James’s Hospital, Dublin 8, IrelandMedical Physics and Bioengineering Department, St. James’s Hospital, Dublin 8, IrelandAntenna & High Frequency Research Centre, Technological University Dublin, Dublin 8, IrelandDET—Department of Electronics and Telecommunications, Politecnico di Torino, 10129 Torino, ItalyDepartment of Radiology, Mayo Clinic, Rochester, MN 55905, USAThe aim of this work was to develop multimodal anthropomorphic breast phantoms suitable for evaluating the imaging performance of a recently-introduced Microwave Imaging (MWI) technique in comparison to the established diagnostic imaging modalities of Magnetic Resonance Imaging (MRI), Ultrasound (US), mammography and Computed Tomography (CT). MWI is an emerging technique with significant potential to supplement established imaging techniques to improve diagnostic confidence for breast cancer detection. To date, numerical simulations have been used to assess the different MWI scanning and image reconstruction algorithms in current use, while only a few clinical trials have been conducted. To bridge the gap between the numerical simulation environment and a more realistic diagnostic scenario, anthropomorphic phantoms which mimic breast tissues in terms of their heterogeneity, anatomy, morphology, and mechanical and dielectric characteristics, may be used. Key in this regard is achieving realism in the imaging appearance of the different healthy and pathologic tissue types for each of the modalities, taking into consideration the differing imaging and contrast mechanisms for each modality. Suitable phantoms can thus be used by radiologists to correlate image findings between the emerging MWI technique and the more familiar images generated by the conventional modalities. Two phantoms were developed in this study, representing difficult-to-image and easy-to-image patients: the former contained a complex boundary between the mammary fat and fibroglandular tissues, extracted from real patient MRI datasets, while the latter contained a simpler and less morphologically accurate interface. Both phantoms were otherwise identical, with tissue-mimicking materials (TMMs) developed to mimic skin, subcutaneous fat, fibroglandular tissue, tumor and pectoral muscle. The phantoms’ construction used non-toxic materials, and they were inexpensive and relatively easy to manufacture. Both phantoms were scanned using conventional modalities (MRI, US, mammography and CT) and a recently introduced MWI radar detection procedure called in-coherent Multiple Signal Classification (I-MUSIC). Clinically realistic artifact-free images of the anthropomorphic breast phantoms were obtained using the conventional imaging techniques as well as the emerging technique of MWI.https://www.mdpi.com/1424-8220/20/8/2400microwave imagingdielectric propertiestissue-mimicking materials |
spellingShingle | Giuseppe Ruvio Raffaele Solimene Antonio Cuccaro Gaia Fiaschetti Andrew J. Fagan Sean Cournane Jennie Cooke Max J. Ammann Jorge Tobon Jacinta E. Browne Multimodal Breast Phantoms for Microwave, Ultrasound, Mammography, Magnetic Resonance and Computed Tomography Imaging Sensors microwave imaging dielectric properties tissue-mimicking materials |
title | Multimodal Breast Phantoms for Microwave, Ultrasound, Mammography, Magnetic Resonance and Computed Tomography Imaging |
title_full | Multimodal Breast Phantoms for Microwave, Ultrasound, Mammography, Magnetic Resonance and Computed Tomography Imaging |
title_fullStr | Multimodal Breast Phantoms for Microwave, Ultrasound, Mammography, Magnetic Resonance and Computed Tomography Imaging |
title_full_unstemmed | Multimodal Breast Phantoms for Microwave, Ultrasound, Mammography, Magnetic Resonance and Computed Tomography Imaging |
title_short | Multimodal Breast Phantoms for Microwave, Ultrasound, Mammography, Magnetic Resonance and Computed Tomography Imaging |
title_sort | multimodal breast phantoms for microwave ultrasound mammography magnetic resonance and computed tomography imaging |
topic | microwave imaging dielectric properties tissue-mimicking materials |
url | https://www.mdpi.com/1424-8220/20/8/2400 |
work_keys_str_mv | AT giusepperuvio multimodalbreastphantomsformicrowaveultrasoundmammographymagneticresonanceandcomputedtomographyimaging AT raffaelesolimene multimodalbreastphantomsformicrowaveultrasoundmammographymagneticresonanceandcomputedtomographyimaging AT antoniocuccaro multimodalbreastphantomsformicrowaveultrasoundmammographymagneticresonanceandcomputedtomographyimaging AT gaiafiaschetti multimodalbreastphantomsformicrowaveultrasoundmammographymagneticresonanceandcomputedtomographyimaging AT andrewjfagan multimodalbreastphantomsformicrowaveultrasoundmammographymagneticresonanceandcomputedtomographyimaging AT seancournane multimodalbreastphantomsformicrowaveultrasoundmammographymagneticresonanceandcomputedtomographyimaging AT jenniecooke multimodalbreastphantomsformicrowaveultrasoundmammographymagneticresonanceandcomputedtomographyimaging AT maxjammann multimodalbreastphantomsformicrowaveultrasoundmammographymagneticresonanceandcomputedtomographyimaging AT jorgetobon multimodalbreastphantomsformicrowaveultrasoundmammographymagneticresonanceandcomputedtomographyimaging AT jacintaebrowne multimodalbreastphantomsformicrowaveultrasoundmammographymagneticresonanceandcomputedtomographyimaging |