Protein Quantitative Method Based on Determination of Amino Acid by LC-ID-MSLI

In order to quantitate protein, a liquid chromatography-isotope dilution mass spectrometry method for the analysis of amino acids in protein hydrolysate was established. The protein was hydrolyzed at 130 ℃ in the presence of 6 mol/L hydrochloric acid solution, and separated by Hypercarb porous grap...

Full description

Bibliographic Details
Main Author: Yongli, GAO Yanqiu, XUE Minjie, HAO Yuhong, LI Jie
Format: Article
Language:zho
Published: Editorial Board of Journal of Isotopes 2023-12-01
Series:Journal of Isotopes
Subjects:
Online Access:https://tws.xml-journal.net/cn/article/doi/10.7538/tws.2023.youxian.013
_version_ 1827357541692080128
author Yongli, GAO Yanqiu, XUE Minjie, HAO Yuhong, LI Jie
author_facet Yongli, GAO Yanqiu, XUE Minjie, HAO Yuhong, LI Jie
author_sort Yongli, GAO Yanqiu, XUE Minjie, HAO Yuhong, LI Jie
collection DOAJ
description In order to quantitate protein, a liquid chromatography-isotope dilution mass spectrometry method for the analysis of amino acids in protein hydrolysate was established. The protein was hydrolyzed at 130 ℃ in the presence of 6 mol/L hydrochloric acid solution, and separated by Hypercarb porous graphite carbon chromatography column and 0.1% perfluoropentanoic acid aqueous solution/acetonitrile mobile phase system. Five stable amino acids (proline, valine, leucine, isoleucine and phenylalanine) were selected for quantitative determination with their corresponding stable isotope markers as internal standard, and the absolute quantitative determination of protein was achieved by combining protein sequence information. The linear relationship of the five amino acids is good within the range of 10-1 000 ng/mL (R2>0.995), the limit of detection and the limit of quantification are between 0.02-0.07 ng/mL and 0.06-0.2 ng/mL, respectively. The recovery at three different levels is between 97.0%-102.4%, and the relative standard deviation is between 1.1%-3.0%. The analysis results of human IgG monoclonal antibody to nucleocapsid protein solution reference material of 2019 Novel Coronavirus and the measurement results of national metrological comparison of 2019nCovid nucleocapsid protein are satisfactory, which proves that the method has sufficient accuracy for protein determination.
first_indexed 2024-03-08T05:34:20Z
format Article
id doaj.art-d14a3d26d17e4ba19bb4b839d5d85232
institution Directory Open Access Journal
issn 1000-7512
language zho
last_indexed 2024-03-08T05:34:20Z
publishDate 2023-12-01
publisher Editorial Board of Journal of Isotopes
record_format Article
series Journal of Isotopes
spelling doaj.art-d14a3d26d17e4ba19bb4b839d5d852322024-02-06T01:58:18ZzhoEditorial Board of Journal of IsotopesJournal of Isotopes1000-75122023-12-01366598604Protein Quantitative Method Based on Determination of Amino Acid by LC-ID-MSLIYongli, GAO Yanqiu, XUE Minjie, HAO Yuhong, LI Jie0Shanghai Key Laboratory of Online Testing and Control Technology, Shanghai Institute of Measurement and Testing Technology, Shanghai 201203, China In order to quantitate protein, a liquid chromatography-isotope dilution mass spectrometry method for the analysis of amino acids in protein hydrolysate was established. The protein was hydrolyzed at 130 ℃ in the presence of 6 mol/L hydrochloric acid solution, and separated by Hypercarb porous graphite carbon chromatography column and 0.1% perfluoropentanoic acid aqueous solution/acetonitrile mobile phase system. Five stable amino acids (proline, valine, leucine, isoleucine and phenylalanine) were selected for quantitative determination with their corresponding stable isotope markers as internal standard, and the absolute quantitative determination of protein was achieved by combining protein sequence information. The linear relationship of the five amino acids is good within the range of 10-1 000 ng/mL (R2>0.995), the limit of detection and the limit of quantification are between 0.02-0.07 ng/mL and 0.06-0.2 ng/mL, respectively. The recovery at three different levels is between 97.0%-102.4%, and the relative standard deviation is between 1.1%-3.0%. The analysis results of human IgG monoclonal antibody to nucleocapsid protein solution reference material of 2019 Novel Coronavirus and the measurement results of national metrological comparison of 2019nCovid nucleocapsid protein are satisfactory, which proves that the method has sufficient accuracy for protein determination.https://tws.xml-journal.net/cn/article/doi/10.7538/tws.2023.youxian.013lc-ms/msisotope diluted mass spectrometryamino acidprotein
spellingShingle Yongli, GAO Yanqiu, XUE Minjie, HAO Yuhong, LI Jie
Protein Quantitative Method Based on Determination of Amino Acid by LC-ID-MSLI
Journal of Isotopes
lc-ms/ms
isotope diluted mass spectrometry
amino acid
protein
title Protein Quantitative Method Based on Determination of Amino Acid by LC-ID-MSLI
title_full Protein Quantitative Method Based on Determination of Amino Acid by LC-ID-MSLI
title_fullStr Protein Quantitative Method Based on Determination of Amino Acid by LC-ID-MSLI
title_full_unstemmed Protein Quantitative Method Based on Determination of Amino Acid by LC-ID-MSLI
title_short Protein Quantitative Method Based on Determination of Amino Acid by LC-ID-MSLI
title_sort protein quantitative method based on determination of amino acid by lc id msli
topic lc-ms/ms
isotope diluted mass spectrometry
amino acid
protein
url https://tws.xml-journal.net/cn/article/doi/10.7538/tws.2023.youxian.013
work_keys_str_mv AT yongligaoyanqiuxueminjiehaoyuhonglijie proteinquantitativemethodbasedondeterminationofaminoacidbylcidmsli