Numerical Analysis of Magnetized Sheath for Inner Surface Modification

A fluid model of the magnetized sheath has been built using ion motion equation, ion continuity equation, Poisson's equation, and Boltzmann's relationship of electron for plasma-based low-energy ion implantation (PBLEII) inner surface modification of a tube. Along the central axis from the...

Full description

Bibliographic Details
Main Authors: Yi Li, Xiaodan Jing, Quan Yuan, Jiuhui Li
Format: Article
Language:English
Published: IEEE 2019-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/8695700/
Description
Summary:A fluid model of the magnetized sheath has been built using ion motion equation, ion continuity equation, Poisson's equation, and Boltzmann's relationship of electron for plasma-based low-energy ion implantation (PBLEII) inner surface modification of a tube. Along the central axis from the middle piece to the end, the maximum ion impact energy decreases from 1600 to 400 eV, the maximum ion impact angle increases from 7° to 60°, and an implantation dose peak of about twice as much as other place appears near the nozzle. The implantation dose just can compensate for the ion impact energy and angle because the mass transfer mechanism of PBLEII is thermal diffusion and low-energy ion implantation. The uniformity of the modification effect is acceptable along the axial direction of the tube.
ISSN:2169-3536