Macular structure analysis in children withmonocular amblyopia by optical coherence tomography

AIM: To measure the macular structure of amblyopia eyes and non-amblyopia eyes in children with monocular hyperopic amblyopia and in normal children by optical coherence tomography(OCT). <p>METHODS: Fifty-six children with monocular hyperopic amblyopia and 75 normal children were selected. The...

Full description

Bibliographic Details
Main Author: Le Kong
Format: Article
Language:English
Published: Press of International Journal of Ophthalmology (IJO PRESS) 2016-07-01
Series:Guoji Yanke Zazhi
Subjects:
Online Access:http://ies.ijo.cn/cn_publish/2016/7/201607033.pdf
_version_ 1818064304398663680
author Le Kong
author_facet Le Kong
author_sort Le Kong
collection DOAJ
description AIM: To measure the macular structure of amblyopia eyes and non-amblyopia eyes in children with monocular hyperopic amblyopia and in normal children by optical coherence tomography(OCT). <p>METHODS: Fifty-six children with monocular hyperopic amblyopia and 75 normal children were selected. The macular retinal thickness and the macular retinal volume were measured by OCT. Data was used for statistical analysis. <p>RESULTS: The thinnest part of retina was at the center retina, and the thickest part was the inner ring, while the outer ring was thinner than the inner ring in the amblyopia eyes group. Among the four quadrants of the inner ring, the thickest quadrant was the nasal quadrant(335.58±17.42μm),and the thinner part was superior quadrant(326.42±15.36μm), the next was the inferior quadrant,the thinnest part was the temporal quadrant. The trend of outer ring was the same as the inner ring. The quadrant differences of non-amblyopia eyes and normal eyes were same with amblyopia eyes. The center 1mm of macula, nasal quadrant and superior quadrant retinal thickness of inner ring were thicker in amblyopia eyes group than that in non-amblyopia eyes group and normal eyes group(<i>P</i><0.05). The nasal quadrant and superior quadrant retinal thickness of outer ring were also thicker in amblyopia eyes group than that in non-amblyopia eyes group and normal eyes group, but there was no statistical difference between them(<i>P</i>>0. 05). The other quadrant retinal thickness was not different in amblyopia eyes group, non- amblyopia eyes group and normal eyes group(<i>P</i>>0.05). In amblyopia eyes group, non- amblyopia eyes group and normal eyes group, the smallest retinal volume was macular retinal volume, the biggest volume was nasal retinal volume of inner ring, then was superior retinal volume and inferior retinal volume,the smallest was temporal retinal volume. The change of retinal volume in outer ring was same as inner ring. The difference of central 1mm macular retinal volume, nasal quadrant and superior quadrant retinal thickness of inner ring in amblyopia eyes group was statistically significant compared with non-amblyopia eyes group and normal eyes group(<i>P</i><0. 05).The other quadrant retinal volume in mblyopia eyes group, non-amblyopia eyes group and normal eyes group were not statistical different between them(<i>P</i>>0. 05). <p>CONCLUSION: OCT can accurately measure macular retinal structure, the difference of macular retinal structure between amblyopia eyes, non-amblyopia eye and normal eyes may be associated with the peripheral mechanism of amblyopia.
first_indexed 2024-12-10T14:33:52Z
format Article
id doaj.art-d184e4417a5e46f8a33bf3c11c8a48a7
institution Directory Open Access Journal
issn 1672-5123
1672-5123
language English
last_indexed 2024-12-10T14:33:52Z
publishDate 2016-07-01
publisher Press of International Journal of Ophthalmology (IJO PRESS)
record_format Article
series Guoji Yanke Zazhi
spelling doaj.art-d184e4417a5e46f8a33bf3c11c8a48a72022-12-22T01:44:52ZengPress of International Journal of Ophthalmology (IJO PRESS)Guoji Yanke Zazhi1672-51231672-51232016-07-011671332133510.3980/j.issn.1672-5123.2016.7.33Macular structure analysis in children withmonocular amblyopia by optical coherence tomographyLe Kong0Department of Ophthalmology, Changshu No.1 People's Hospital, Changshu Hospital Affiliated to Suzhou University, Changshu 215500, Jiangsu Province, ChinaAIM: To measure the macular structure of amblyopia eyes and non-amblyopia eyes in children with monocular hyperopic amblyopia and in normal children by optical coherence tomography(OCT). <p>METHODS: Fifty-six children with monocular hyperopic amblyopia and 75 normal children were selected. The macular retinal thickness and the macular retinal volume were measured by OCT. Data was used for statistical analysis. <p>RESULTS: The thinnest part of retina was at the center retina, and the thickest part was the inner ring, while the outer ring was thinner than the inner ring in the amblyopia eyes group. Among the four quadrants of the inner ring, the thickest quadrant was the nasal quadrant(335.58±17.42μm),and the thinner part was superior quadrant(326.42±15.36μm), the next was the inferior quadrant,the thinnest part was the temporal quadrant. The trend of outer ring was the same as the inner ring. The quadrant differences of non-amblyopia eyes and normal eyes were same with amblyopia eyes. The center 1mm of macula, nasal quadrant and superior quadrant retinal thickness of inner ring were thicker in amblyopia eyes group than that in non-amblyopia eyes group and normal eyes group(<i>P</i><0.05). The nasal quadrant and superior quadrant retinal thickness of outer ring were also thicker in amblyopia eyes group than that in non-amblyopia eyes group and normal eyes group, but there was no statistical difference between them(<i>P</i>>0. 05). The other quadrant retinal thickness was not different in amblyopia eyes group, non- amblyopia eyes group and normal eyes group(<i>P</i>>0.05). In amblyopia eyes group, non- amblyopia eyes group and normal eyes group, the smallest retinal volume was macular retinal volume, the biggest volume was nasal retinal volume of inner ring, then was superior retinal volume and inferior retinal volume,the smallest was temporal retinal volume. The change of retinal volume in outer ring was same as inner ring. The difference of central 1mm macular retinal volume, nasal quadrant and superior quadrant retinal thickness of inner ring in amblyopia eyes group was statistically significant compared with non-amblyopia eyes group and normal eyes group(<i>P</i><0. 05).The other quadrant retinal volume in mblyopia eyes group, non-amblyopia eyes group and normal eyes group were not statistical different between them(<i>P</i>>0. 05). <p>CONCLUSION: OCT can accurately measure macular retinal structure, the difference of macular retinal structure between amblyopia eyes, non-amblyopia eye and normal eyes may be associated with the peripheral mechanism of amblyopia.http://ies.ijo.cn/cn_publish/2016/7/201607033.pdfhyperopiaamblyopiaoptical coherence tomographymacular structuremacular structure
spellingShingle Le Kong
Macular structure analysis in children withmonocular amblyopia by optical coherence tomography
Guoji Yanke Zazhi
hyperopia
amblyopia
optical coherence tomography
macular structure
macular structure
title Macular structure analysis in children withmonocular amblyopia by optical coherence tomography
title_full Macular structure analysis in children withmonocular amblyopia by optical coherence tomography
title_fullStr Macular structure analysis in children withmonocular amblyopia by optical coherence tomography
title_full_unstemmed Macular structure analysis in children withmonocular amblyopia by optical coherence tomography
title_short Macular structure analysis in children withmonocular amblyopia by optical coherence tomography
title_sort macular structure analysis in children withmonocular amblyopia by optical coherence tomography
topic hyperopia
amblyopia
optical coherence tomography
macular structure
macular structure
url http://ies.ijo.cn/cn_publish/2016/7/201607033.pdf
work_keys_str_mv AT lekong macularstructureanalysisinchildrenwithmonocularamblyopiabyopticalcoherencetomography