Ekstarsi Ciri Citra Ultrasonografi Abdomen pada Regional 3, 6 dan 8 Menggunakan Metode Gray Level Co-Occurance Matrix (GLCM)

ltrasonography is the most popular modality used for clinical applications to detect abnormalities related to abdominal organs such as the liver, kidneys, uterus and other organs. In the context of organ recognition, image processing techniques are needed to improve image quality without eliminating...

Full description

Bibliographic Details
Main Authors: Giner Maslebu, Matius Umbu Laga, Andreas Setiawan
Format: Article
Language:English
Published: Lambung Mangkurat University Press 2020-05-01
Series:Jurnal Fisika Flux
Subjects:
Online Access:https://ppjp.ulm.ac.id/journal/index.php/f/article/view/6510
_version_ 1819205827429400576
author Giner Maslebu
Matius Umbu Laga
Andreas Setiawan
author_facet Giner Maslebu
Matius Umbu Laga
Andreas Setiawan
author_sort Giner Maslebu
collection DOAJ
description ltrasonography is the most popular modality used for clinical applications to detect abnormalities related to abdominal organs such as the liver, kidneys, uterus and other organs. In the context of organ recognition, image processing techniques are needed to improve image quality without eliminating important information contained in it. The purpose of this study was to identify prominent features of organs found in regional 3 (left liver lobe), 6 (left kidney and spleen) and 8 (bladder and prostate) from the abdomen using the gray level co-assurance matrix (GLCM) method. with features that are used, among others: contrast, correlation, energy and homogenity in the direction 0°, 45°, 90° and 135°. The results obtained show that each organ has a GLCM value that varies between one organ and another organ, namely regional Hypochondrium Dexta for left liver lobe organ, contrast 〖5.1473 x10〗^(-4)-〖1 x10〗^(-3), corrlation 0.9786-0.9890, energy 0.9073-0.9754 and homognity 0.9995 - 0.9997. Lumbaris Sinistra Regional for left ginjla organ, contrast 〖3.8526 x10〗^(-4)- 〖6.2959 x10〗^(-4), corrlation 0.9737 - 0.9862, energy 0.9737 - 0.9862 and homognity 0.9997-0.9998 while spleen, contrast 〖6.0350 x10〗^(-4)  - 9.3762 x 〖10〗^(-4), corrlation 0.9640-0.9812, energy 0.9493-0.9816 and homognity 0.9995 - 0.9997. Regional Hipogastrum in bladder organs, contrast 4.0614〖 x10〗^(-4)- 9.9296 〖x10〗^(-4), corrlation 0.9770 - 0.9890, energy 0.9085 - 0.9884 and homognity 0.9995 - 0.9998 for prostate organs, contrast 3.0383 〖x10〗^(-4)-3.1532 〖x10〗^(-4), corrlation 0.9727 - 0.9738, energy 0.9877 - 0.9885 and homognity 0.9998. The range values represent the organs studied. The results of the research obtained indicate that the features of GLCM can be used to identify organs in regions 3, 6 and 8.
first_indexed 2024-12-23T04:57:53Z
format Article
id doaj.art-d1933517f7104c028b8987ce668b10b4
institution Directory Open Access Journal
issn 1829-796X
2541-1713
language English
last_indexed 2024-12-23T04:57:53Z
publishDate 2020-05-01
publisher Lambung Mangkurat University Press
record_format Article
series Jurnal Fisika Flux
spelling doaj.art-d1933517f7104c028b8987ce668b10b42022-12-21T17:59:17ZengLambung Mangkurat University PressJurnal Fisika Flux1829-796X2541-17132020-05-01172808710.20527/flux.v17i2.65106029Ekstarsi Ciri Citra Ultrasonografi Abdomen pada Regional 3, 6 dan 8 Menggunakan Metode Gray Level Co-Occurance Matrix (GLCM)Giner Maslebu0Matius Umbu Laga1Andreas Setiawan2Program Studi Fisika Fakultas Sains dan Matematika Universitas Kristern Satya Wacana, SalatigaProgram Studi Fisika Fakultas Sains dan Matematika Universitas Kristern Satya Wacana, SalatigaProgram Studi Fisika Fakultas Sains dan Matematika Universitas Kristern Satya Wacana, Salatigaltrasonography is the most popular modality used for clinical applications to detect abnormalities related to abdominal organs such as the liver, kidneys, uterus and other organs. In the context of organ recognition, image processing techniques are needed to improve image quality without eliminating important information contained in it. The purpose of this study was to identify prominent features of organs found in regional 3 (left liver lobe), 6 (left kidney and spleen) and 8 (bladder and prostate) from the abdomen using the gray level co-assurance matrix (GLCM) method. with features that are used, among others: contrast, correlation, energy and homogenity in the direction 0°, 45°, 90° and 135°. The results obtained show that each organ has a GLCM value that varies between one organ and another organ, namely regional Hypochondrium Dexta for left liver lobe organ, contrast 〖5.1473 x10〗^(-4)-〖1 x10〗^(-3), corrlation 0.9786-0.9890, energy 0.9073-0.9754 and homognity 0.9995 - 0.9997. Lumbaris Sinistra Regional for left ginjla organ, contrast 〖3.8526 x10〗^(-4)- 〖6.2959 x10〗^(-4), corrlation 0.9737 - 0.9862, energy 0.9737 - 0.9862 and homognity 0.9997-0.9998 while spleen, contrast 〖6.0350 x10〗^(-4)  - 9.3762 x 〖10〗^(-4), corrlation 0.9640-0.9812, energy 0.9493-0.9816 and homognity 0.9995 - 0.9997. Regional Hipogastrum in bladder organs, contrast 4.0614〖 x10〗^(-4)- 9.9296 〖x10〗^(-4), corrlation 0.9770 - 0.9890, energy 0.9085 - 0.9884 and homognity 0.9995 - 0.9998 for prostate organs, contrast 3.0383 〖x10〗^(-4)-3.1532 〖x10〗^(-4), corrlation 0.9727 - 0.9738, energy 0.9877 - 0.9885 and homognity 0.9998. The range values represent the organs studied. The results of the research obtained indicate that the features of GLCM can be used to identify organs in regions 3, 6 and 8.https://ppjp.ulm.ac.id/journal/index.php/f/article/view/6510abdomenultrasound imageglcm.
spellingShingle Giner Maslebu
Matius Umbu Laga
Andreas Setiawan
Ekstarsi Ciri Citra Ultrasonografi Abdomen pada Regional 3, 6 dan 8 Menggunakan Metode Gray Level Co-Occurance Matrix (GLCM)
Jurnal Fisika Flux
abdomen
ultrasound image
glcm.
title Ekstarsi Ciri Citra Ultrasonografi Abdomen pada Regional 3, 6 dan 8 Menggunakan Metode Gray Level Co-Occurance Matrix (GLCM)
title_full Ekstarsi Ciri Citra Ultrasonografi Abdomen pada Regional 3, 6 dan 8 Menggunakan Metode Gray Level Co-Occurance Matrix (GLCM)
title_fullStr Ekstarsi Ciri Citra Ultrasonografi Abdomen pada Regional 3, 6 dan 8 Menggunakan Metode Gray Level Co-Occurance Matrix (GLCM)
title_full_unstemmed Ekstarsi Ciri Citra Ultrasonografi Abdomen pada Regional 3, 6 dan 8 Menggunakan Metode Gray Level Co-Occurance Matrix (GLCM)
title_short Ekstarsi Ciri Citra Ultrasonografi Abdomen pada Regional 3, 6 dan 8 Menggunakan Metode Gray Level Co-Occurance Matrix (GLCM)
title_sort ekstarsi ciri citra ultrasonografi abdomen pada regional 3 6 dan 8 menggunakan metode gray level co occurance matrix glcm
topic abdomen
ultrasound image
glcm.
url https://ppjp.ulm.ac.id/journal/index.php/f/article/view/6510
work_keys_str_mv AT ginermaslebu ekstarsiciricitraultrasonografiabdomenpadaregional36dan8menggunakanmetodegraylevelcooccurancematrixglcm
AT matiusumbulaga ekstarsiciricitraultrasonografiabdomenpadaregional36dan8menggunakanmetodegraylevelcooccurancematrixglcm
AT andreassetiawan ekstarsiciricitraultrasonografiabdomenpadaregional36dan8menggunakanmetodegraylevelcooccurancematrixglcm