Perioperative peri-implant fracture after osteosynthesis for geriatric femoral pertrochanteric fracture with the linear compression integrated screw intramedullary nail system (INTERTAN™): a retrospective study
Abstract Background Osteosynthesis for geriatric femoral pertrochanteric fractures using the linear compression integrated screw intramedullary nail system (INTERTAN™) has become popular. Nonetheless, cases of perioperative peri-implant fractures have been reported following this surgical technique....
Main Authors: | Chih-Yang Lai, Chang-Heng Liu, Po-Ju Lai, Yung-Heng Hsu, Ying-Chao Chou, Yi-Hsun Yu |
---|---|
Format: | Article |
Language: | English |
Published: |
BMC
2023-12-01
|
Series: | Journal of Orthopaedic Surgery and Research |
Subjects: | |
Online Access: | https://doi.org/10.1186/s13018-023-04441-w |
Similar Items
-
Midterm results of consecutive periprosthetic femoral fractures Vancouver type A and B
by: Klemens Trieb, et al.
Published: (2016-08-01) -
Biomechanical evaluation of a new intramedullary nail compared with proximal femoral nail antirotation and InterTAN for the management of femoral intertrochanteric fractures
by: ChaoFeng Wang, et al.
Published: (2024-02-01) -
Intramedullary nailing for pertrochanteric fractures of proximal femur: a consecutive series of 323 patients treated with two devices
by: Pompeo Catania, et al.
Published: (2019-12-01) -
Periprosthetic Intertrochanteric Fracture between Hip Resurfacing and Retrograde Nail
by: Sandeep Soin, MD, et al.
Published: (2020-12-01) -
Comparative study between lateral decubitus and traction table for treatment of pertrochanteric fractures with cephalomedullary nails ☆
by: Eric Fernando de Souza, et al.