Dosimetric characterization of an intensity-modulated X-ray brachytherapy system

Purpose: An intensity-modulated X-ray brachytherapy system is being developed for various clinical applications. This new system makes it possible for clinical staff to control energy as well as dose rate for different tumor sites according to their sizes and radiobiological characteristics. Materia...

Full description

Bibliographic Details
Main Authors: Sung-Woo Lee, Evgeny Sozontov, Emil Strumban, Fang-Fang Yin
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2018-01-01
Series:Journal of Medical Physics
Subjects:
Online Access:http://www.jmp.org.in/article.asp?issn=0971-6203;year=2018;volume=43;issue=4;spage=247;epage=254;aulast=Lee
_version_ 1818850746605502464
author Sung-Woo Lee
Evgeny Sozontov
Emil Strumban
Fang-Fang Yin
author_facet Sung-Woo Lee
Evgeny Sozontov
Emil Strumban
Fang-Fang Yin
author_sort Sung-Woo Lee
collection DOAJ
description Purpose: An intensity-modulated X-ray brachytherapy system is being developed for various clinical applications. This new system makes it possible for clinical staff to control energy as well as dose rate for different tumor sites according to their sizes and radiobiological characteristics. Materials and Methods: This system is mainly composed of an X-ray tube, guide tube collimation, and secondary (pseudo) target. Due to its configuration, convenient modulations of fluorescent X-ray energy and intensity are possible. To observe applicability of this novel system for various primary and secondary target combinations, Monte Carlo simulation using MCNP5 was performed, and air measurements were done. As a primary and pseudo-target combination, silver–molybdenum (Ag-Mo), tungsten–neodymium (W-Nd), and tungsten–erbium (W-Er) were used for the calculation for dose profile. Specifically, a dose distribution was calculated around each of these target combinations. Dose distributions as a function of target angles were also calculated. The Ag-Mo combination was analyzed for Cartesian coordinates of xy, xz, and yz planes of the pseudo-target to observe dose distribution as a function of the angle of secondary target. Results: The results showed that radial dose fall-off of Ag-Mo was greater than commercially available brachytherapy sources (103Pd and 125I) due to its low characteristic X-ray energy. Conclusions: Dose distribution variance should be considered in beam modulation for clinical application. Dynamic movement of the pseudo-target is feasible and remains as a subject for future research.
first_indexed 2024-12-19T06:54:02Z
format Article
id doaj.art-d278c9f7eaca435f93eddf591b10e87e
institution Directory Open Access Journal
issn 0971-6203
1998-3913
language English
last_indexed 2024-12-19T06:54:02Z
publishDate 2018-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Journal of Medical Physics
spelling doaj.art-d278c9f7eaca435f93eddf591b10e87e2022-12-21T20:31:36ZengWolters Kluwer Medknow PublicationsJournal of Medical Physics0971-62031998-39132018-01-0143424725410.4103/jmp.JMP_52_18Dosimetric characterization of an intensity-modulated X-ray brachytherapy systemSung-Woo LeeEvgeny SozontovEmil StrumbanFang-Fang YinPurpose: An intensity-modulated X-ray brachytherapy system is being developed for various clinical applications. This new system makes it possible for clinical staff to control energy as well as dose rate for different tumor sites according to their sizes and radiobiological characteristics. Materials and Methods: This system is mainly composed of an X-ray tube, guide tube collimation, and secondary (pseudo) target. Due to its configuration, convenient modulations of fluorescent X-ray energy and intensity are possible. To observe applicability of this novel system for various primary and secondary target combinations, Monte Carlo simulation using MCNP5 was performed, and air measurements were done. As a primary and pseudo-target combination, silver–molybdenum (Ag-Mo), tungsten–neodymium (W-Nd), and tungsten–erbium (W-Er) were used for the calculation for dose profile. Specifically, a dose distribution was calculated around each of these target combinations. Dose distributions as a function of target angles were also calculated. The Ag-Mo combination was analyzed for Cartesian coordinates of xy, xz, and yz planes of the pseudo-target to observe dose distribution as a function of the angle of secondary target. Results: The results showed that radial dose fall-off of Ag-Mo was greater than commercially available brachytherapy sources (103Pd and 125I) due to its low characteristic X-ray energy. Conclusions: Dose distribution variance should be considered in beam modulation for clinical application. Dynamic movement of the pseudo-target is feasible and remains as a subject for future research.http://www.jmp.org.in/article.asp?issn=0971-6203;year=2018;volume=43;issue=4;spage=247;epage=254;aulast=LeeBrachytherapydosimetryintensity modulatedX-ray
spellingShingle Sung-Woo Lee
Evgeny Sozontov
Emil Strumban
Fang-Fang Yin
Dosimetric characterization of an intensity-modulated X-ray brachytherapy system
Journal of Medical Physics
Brachytherapy
dosimetry
intensity modulated
X-ray
title Dosimetric characterization of an intensity-modulated X-ray brachytherapy system
title_full Dosimetric characterization of an intensity-modulated X-ray brachytherapy system
title_fullStr Dosimetric characterization of an intensity-modulated X-ray brachytherapy system
title_full_unstemmed Dosimetric characterization of an intensity-modulated X-ray brachytherapy system
title_short Dosimetric characterization of an intensity-modulated X-ray brachytherapy system
title_sort dosimetric characterization of an intensity modulated x ray brachytherapy system
topic Brachytherapy
dosimetry
intensity modulated
X-ray
url http://www.jmp.org.in/article.asp?issn=0971-6203;year=2018;volume=43;issue=4;spage=247;epage=254;aulast=Lee
work_keys_str_mv AT sungwoolee dosimetriccharacterizationofanintensitymodulatedxraybrachytherapysystem
AT evgenysozontov dosimetriccharacterizationofanintensitymodulatedxraybrachytherapysystem
AT emilstrumban dosimetriccharacterizationofanintensitymodulatedxraybrachytherapysystem
AT fangfangyin dosimetriccharacterizationofanintensitymodulatedxraybrachytherapysystem