Insights Into Interaction Between Clip Device and the Mitral Valve Apparatus in the Human Heart

Precise appreciation of the 3-dimensional relationship between the edge-to-edge clips and mitral valve apparatus remains clinically challenging. We demonstrate the images of clips observed in situ 4 years after implantation. Detailed observation from this case helps improve our understanding of 3-di...

Full description

Bibliographic Details
Main Authors: Takanori Sato, MD, PhD, Issam D. Moussa, MD, MBA, Peter Hanna, MD, PhD, Kalyanam Shivkumar, MD, PhD, Shumpei Mori, MD, PhD
Format: Article
Language:English
Published: Elsevier 2023-09-01
Series:JACC: Case Reports
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2666084923003297
_version_ 1827861361062838272
author Takanori Sato, MD, PhD
Issam D. Moussa, MD, MBA
Peter Hanna, MD, PhD
Kalyanam Shivkumar, MD, PhD
Shumpei Mori, MD, PhD
author_facet Takanori Sato, MD, PhD
Issam D. Moussa, MD, MBA
Peter Hanna, MD, PhD
Kalyanam Shivkumar, MD, PhD
Shumpei Mori, MD, PhD
author_sort Takanori Sato, MD, PhD
collection DOAJ
description Precise appreciation of the 3-dimensional relationship between the edge-to-edge clips and mitral valve apparatus remains clinically challenging. We demonstrate the images of clips observed in situ 4 years after implantation. Detailed observation from this case helps improve our understanding of 3-dimensional clinical cardiac anatomy related to transcatheter edge-to-edge mitral valve repair. (Level of Difficulty: Intermediate.)
first_indexed 2024-03-12T13:36:44Z
format Article
id doaj.art-d282d706a0dc42e188e21696ca0c2217
institution Directory Open Access Journal
issn 2666-0849
language English
last_indexed 2024-03-12T13:36:44Z
publishDate 2023-09-01
publisher Elsevier
record_format Article
series JACC: Case Reports
spelling doaj.art-d282d706a0dc42e188e21696ca0c22172023-08-24T04:35:38ZengElsevierJACC: Case Reports2666-08492023-09-0122101999Insights Into Interaction Between Clip Device and the Mitral Valve Apparatus in the Human HeartTakanori Sato, MD, PhD0Issam D. Moussa, MD, MBA1Peter Hanna, MD, PhD2Kalyanam Shivkumar, MD, PhD3Shumpei Mori, MD, PhD4University of California Los Angeles (UCLA) Cardiac Arrhythmia Center, Cardiovascular & Interventional Programs, UCLA Health System, David Geffen School of Medicine at UCLA, Los Angeles, California, USACarle Illinois College of Medicine, University of Illinois, Carle Heart and Vascular Institute, Champaign, Illinois, USAUniversity of California Los Angeles (UCLA) Cardiac Arrhythmia Center, Cardiovascular & Interventional Programs, UCLA Health System, David Geffen School of Medicine at UCLA, Los Angeles, California, USAUniversity of California Los Angeles (UCLA) Cardiac Arrhythmia Center, Cardiovascular & Interventional Programs, UCLA Health System, David Geffen School of Medicine at UCLA, Los Angeles, California, USAUniversity of California Los Angeles (UCLA) Cardiac Arrhythmia Center, Cardiovascular & Interventional Programs, UCLA Health System, David Geffen School of Medicine at UCLA, Los Angeles, California, USA; Address for correspondence: Dr Shumpei Mori, UCLA Cardiac Arrhythmia Center, UCLA Health System, David Geffen School of Medicine at UCLA, Center of Health Sciences, Suite 46-119C, 650 Charles E. Young Dr South, Los Angeles, California 90095, USA.Precise appreciation of the 3-dimensional relationship between the edge-to-edge clips and mitral valve apparatus remains clinically challenging. We demonstrate the images of clips observed in situ 4 years after implantation. Detailed observation from this case helps improve our understanding of 3-dimensional clinical cardiac anatomy related to transcatheter edge-to-edge mitral valve repair. (Level of Difficulty: Intermediate.)http://www.sciencedirect.com/science/article/pii/S2666084923003297anatomychordae tendineaeMitraClipmitral regurgitationtranscatheter edge-to-edge repair
spellingShingle Takanori Sato, MD, PhD
Issam D. Moussa, MD, MBA
Peter Hanna, MD, PhD
Kalyanam Shivkumar, MD, PhD
Shumpei Mori, MD, PhD
Insights Into Interaction Between Clip Device and the Mitral Valve Apparatus in the Human Heart
JACC: Case Reports
anatomy
chordae tendineae
MitraClip
mitral regurgitation
transcatheter edge-to-edge repair
title Insights Into Interaction Between Clip Device and the Mitral Valve Apparatus in the Human Heart
title_full Insights Into Interaction Between Clip Device and the Mitral Valve Apparatus in the Human Heart
title_fullStr Insights Into Interaction Between Clip Device and the Mitral Valve Apparatus in the Human Heart
title_full_unstemmed Insights Into Interaction Between Clip Device and the Mitral Valve Apparatus in the Human Heart
title_short Insights Into Interaction Between Clip Device and the Mitral Valve Apparatus in the Human Heart
title_sort insights into interaction between clip device and the mitral valve apparatus in the human heart
topic anatomy
chordae tendineae
MitraClip
mitral regurgitation
transcatheter edge-to-edge repair
url http://www.sciencedirect.com/science/article/pii/S2666084923003297
work_keys_str_mv AT takanorisatomdphd insightsintointeractionbetweenclipdeviceandthemitralvalveapparatusinthehumanheart
AT issamdmoussamdmba insightsintointeractionbetweenclipdeviceandthemitralvalveapparatusinthehumanheart
AT peterhannamdphd insightsintointeractionbetweenclipdeviceandthemitralvalveapparatusinthehumanheart
AT kalyanamshivkumarmdphd insightsintointeractionbetweenclipdeviceandthemitralvalveapparatusinthehumanheart
AT shumpeimorimdphd insightsintointeractionbetweenclipdeviceandthemitralvalveapparatusinthehumanheart