Pengaruh Ion Na+, Ion Hg2+ dan Ion Cr3+ Terhadap Kinerja Sensor Potensiometri Ion Timbal (II) Tipe Kawat Terlapis Berbasis Pirofilit

Generally ionophores  (active materials) in a potentiometric is derived from organic compounds. In this research used ionophores derived from ainorganic compounds that pyrophyllite. Potentiometric sensors lead (II) ions based on pyrophyllite as ionofor has been developed. The electrode had  polyvini...

Full description

Bibliographic Details
Main Authors: Qanitah Fardiyah, Barlah Berlianti, Ika Rosemiyani
Format: Article
Language:Indonesian
Published: Syarif Hidayatullah Jakarta State Islamic University 2015-11-01
Series:Jurnal Kimia Valensi
Subjects:
Online Access:http://journal.uinjkt.ac.id/index.php/valensi/article/view/3144
_version_ 1811189938727682048
author Qanitah Fardiyah
Barlah Berlianti
Ika Rosemiyani
author_facet Qanitah Fardiyah
Barlah Berlianti
Ika Rosemiyani
author_sort Qanitah Fardiyah
collection DOAJ
description Generally ionophores  (active materials) in a potentiometric is derived from organic compounds. In this research used ionophores derived from ainorganic compounds that pyrophyllite. Potentiometric sensors lead (II) ions based on pyrophyllite as ionofor has been developed. The electrode had  polyvinilchloride (PVC) as polymer matrix and dioctylpthalate (DOP) as plasticizer. It showed a good Nernstian slope of 29.33 mV/decade, a lead linear range concentration between 10-1- 10-5 M, and detection limit of 8.054 x10-6 M  (equal with 1.669 ppm of lead). By using the electrode, the objectives of this research were to investigate the effect of interfering ions  Na+, ion Hg2+ and ion Cr3+ to the performance of the potentiometric sensors lead(II) ion based pyrophyllite coated wire type. The selective coefficients (kij) were determined using the mix solution methode  at  10-3 M of interfering ion. The result showed that the potentiometric sensors lead(II) ions based  on pyrophyllite coated wire type could be used optimally at  pH 5. The potentiometric sensors lead(II) ion based pyrophyllite coated wire type showed a good selectivity for interfering ions (Na+, Hg2+, dan Cr3+) and showed no interference to the performance of the potentiometric sensors lead (II) ion based pyrophyllite coated wire type with selectivity order of Pb2+> Hg2+> Cr3+> Na+. DOI :http://dx.doi.org/10.15408/jkv.v0i0.3144
first_indexed 2024-04-11T14:42:08Z
format Article
id doaj.art-d28949879aed4bdd9ce8ae325900e456
institution Directory Open Access Journal
issn 2460-6065
2548-3013
language Indonesian
last_indexed 2024-04-11T14:42:08Z
publishDate 2015-11-01
publisher Syarif Hidayatullah Jakarta State Islamic University
record_format Article
series Jurnal Kimia Valensi
spelling doaj.art-d28949879aed4bdd9ce8ae325900e4562022-12-22T04:17:50ZindSyarif Hidayatullah Jakarta State Islamic UniversityJurnal Kimia Valensi2460-60652548-30132015-11-0100808310.15408/jkv.v0i0.31442717Pengaruh Ion Na+, Ion Hg2+ dan Ion Cr3+ Terhadap Kinerja Sensor Potensiometri Ion Timbal (II) Tipe Kawat Terlapis Berbasis PirofilitQanitah Fardiyah0Barlah Berlianti1Ika Rosemiyani2Laboratorium Kimia Analitik Jurusan Kimia Fakultas MIPA Universitas BrawijayaLaboratorium Kimia Analitik Jurusan Kimia Fakultas MIPA Universitas BrawijayaLaboratorium Kimia Analitik Jurusan Kimia Fakultas MIPA Universitas BrawijayaGenerally ionophores  (active materials) in a potentiometric is derived from organic compounds. In this research used ionophores derived from ainorganic compounds that pyrophyllite. Potentiometric sensors lead (II) ions based on pyrophyllite as ionofor has been developed. The electrode had  polyvinilchloride (PVC) as polymer matrix and dioctylpthalate (DOP) as plasticizer. It showed a good Nernstian slope of 29.33 mV/decade, a lead linear range concentration between 10-1- 10-5 M, and detection limit of 8.054 x10-6 M  (equal with 1.669 ppm of lead). By using the electrode, the objectives of this research were to investigate the effect of interfering ions  Na+, ion Hg2+ and ion Cr3+ to the performance of the potentiometric sensors lead(II) ion based pyrophyllite coated wire type. The selective coefficients (kij) were determined using the mix solution methode  at  10-3 M of interfering ion. The result showed that the potentiometric sensors lead(II) ions based  on pyrophyllite coated wire type could be used optimally at  pH 5. The potentiometric sensors lead(II) ion based pyrophyllite coated wire type showed a good selectivity for interfering ions (Na+, Hg2+, dan Cr3+) and showed no interference to the performance of the potentiometric sensors lead (II) ion based pyrophyllite coated wire type with selectivity order of Pb2+> Hg2+> Cr3+> Na+. DOI :http://dx.doi.org/10.15408/jkv.v0i0.3144http://journal.uinjkt.ac.id/index.php/valensi/article/view/3144ion selective electrodecoefficient of selectivityphpyrophyllite
spellingShingle Qanitah Fardiyah
Barlah Berlianti
Ika Rosemiyani
Pengaruh Ion Na+, Ion Hg2+ dan Ion Cr3+ Terhadap Kinerja Sensor Potensiometri Ion Timbal (II) Tipe Kawat Terlapis Berbasis Pirofilit
Jurnal Kimia Valensi
ion selective electrode
coefficient of selectivity
ph
pyrophyllite
title Pengaruh Ion Na+, Ion Hg2+ dan Ion Cr3+ Terhadap Kinerja Sensor Potensiometri Ion Timbal (II) Tipe Kawat Terlapis Berbasis Pirofilit
title_full Pengaruh Ion Na+, Ion Hg2+ dan Ion Cr3+ Terhadap Kinerja Sensor Potensiometri Ion Timbal (II) Tipe Kawat Terlapis Berbasis Pirofilit
title_fullStr Pengaruh Ion Na+, Ion Hg2+ dan Ion Cr3+ Terhadap Kinerja Sensor Potensiometri Ion Timbal (II) Tipe Kawat Terlapis Berbasis Pirofilit
title_full_unstemmed Pengaruh Ion Na+, Ion Hg2+ dan Ion Cr3+ Terhadap Kinerja Sensor Potensiometri Ion Timbal (II) Tipe Kawat Terlapis Berbasis Pirofilit
title_short Pengaruh Ion Na+, Ion Hg2+ dan Ion Cr3+ Terhadap Kinerja Sensor Potensiometri Ion Timbal (II) Tipe Kawat Terlapis Berbasis Pirofilit
title_sort pengaruh ion na ion hg2 dan ion cr3 terhadap kinerja sensor potensiometri ion timbal ii tipe kawat terlapis berbasis pirofilit
topic ion selective electrode
coefficient of selectivity
ph
pyrophyllite
url http://journal.uinjkt.ac.id/index.php/valensi/article/view/3144
work_keys_str_mv AT qanitahfardiyah pengaruhionnaionhg2danioncr3terhadapkinerjasensorpotensiometriiontimbaliitipekawatterlapisberbasispirofilit
AT barlahberlianti pengaruhionnaionhg2danioncr3terhadapkinerjasensorpotensiometriiontimbaliitipekawatterlapisberbasispirofilit
AT ikarosemiyani pengaruhionnaionhg2danioncr3terhadapkinerjasensorpotensiometriiontimbaliitipekawatterlapisberbasispirofilit