Interfractional variation in whole-breast VMAT irradiation: a dosimetric study with complementary SGRT and CBCT patient setup
Abstract Background The dosimetric effect of setup uncertainty and tissue deformations in left-sided whole-breast irradiation with complementary surface-guided radiotherapy (SGRT) and cone-beam computed tomography (CBCT) setup was evaluated. Method Treatment courses of 40.05 Gy prescribed dose in 15...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
BMC
2024-02-01
|
Series: | Radiation Oncology |
Subjects: | |
Online Access: | https://doi.org/10.1186/s13014-024-02418-5 |
_version_ | 1797273774052081664 |
---|---|
author | M. Mankinen T. Virén J. Seppälä T. Koivumäki |
author_facet | M. Mankinen T. Virén J. Seppälä T. Koivumäki |
author_sort | M. Mankinen |
collection | DOAJ |
description | Abstract Background The dosimetric effect of setup uncertainty and tissue deformations in left-sided whole-breast irradiation with complementary surface-guided radiotherapy (SGRT) and cone-beam computed tomography (CBCT) setup was evaluated. Method Treatment courses of 40.05 Gy prescribed dose in 15 fractions were simulated for 29 patients by calculating the dose on deformed CT images, that were based on daily CBCT images, and deforming and accumulating the dose onto the planning CT image. Variability in clinical target volume (CTV) position and shape was assessed as the 95% Hausdorff distance (HD95) between the planning CTV and deformed CTV structures. DVH metrics were evaluated between the planned and simulated cumulative dose distributions using two treatment techniques: tangential volumetric modulated arc therapy (tVMAT) and conventional 3D-conformal radiotherapy (3D-CRT). Results Based on the HD95 values, the variations in CTV shape and position were enclosed by the 5 mm CTV-PTV margin in 85% of treatment fractions using complementary CBCT and SGRT setup. A residual error of 8.6 mm was observed between the initial SGRT setup and CBCT setup. The median CTV V95% coverage was 98.1% (range 93.1–99.8%) with tVMAT and 98.2% (range 84.5–99.7%) with 3D-CRT techniques with CBCT setup. With the initial SGRT-only setup, the corresponding coverages were 96.3% (range 92.6–99.4%) and 96.6% (range 84.2–99.4%), respectively. However, a considerable bias in vertical residual error between initial SGRT setup and CBCT setup was observed. Clinically relevant changes between the planned and cumulative doses to organs-at-risk (OARs) were not observed. Conclusions The CTV-to-PTV margin should not be reduced below 5 mm even with daily CBCT setup. Both tVMAT and 3D-CRT techniques were robust in terms of dose coverage to the target and OARs. Based on the shifts between setup methods, CBCT setup is recommended as a complementary method with SGRT. |
first_indexed | 2024-03-07T14:49:00Z |
format | Article |
id | doaj.art-d2904f15b5c54a2881fcbc9934fdec04 |
institution | Directory Open Access Journal |
issn | 1748-717X |
language | English |
last_indexed | 2024-03-07T14:49:00Z |
publishDate | 2024-02-01 |
publisher | BMC |
record_format | Article |
series | Radiation Oncology |
spelling | doaj.art-d2904f15b5c54a2881fcbc9934fdec042024-03-05T19:51:24ZengBMCRadiation Oncology1748-717X2024-02-0119111110.1186/s13014-024-02418-5Interfractional variation in whole-breast VMAT irradiation: a dosimetric study with complementary SGRT and CBCT patient setupM. Mankinen0T. Virén1J. Seppälä2T. Koivumäki3Deparment of Physics, University of Jyväskylä (JYU)Center of Oncology, Kuopio University Hospital (KUH), The Wellbeing Services Country of North SavoCenter of Oncology, Kuopio University Hospital (KUH), The Wellbeing Services Country of North SavoDeparment of Physics, University of Jyväskylä (JYU)Abstract Background The dosimetric effect of setup uncertainty and tissue deformations in left-sided whole-breast irradiation with complementary surface-guided radiotherapy (SGRT) and cone-beam computed tomography (CBCT) setup was evaluated. Method Treatment courses of 40.05 Gy prescribed dose in 15 fractions were simulated for 29 patients by calculating the dose on deformed CT images, that were based on daily CBCT images, and deforming and accumulating the dose onto the planning CT image. Variability in clinical target volume (CTV) position and shape was assessed as the 95% Hausdorff distance (HD95) between the planning CTV and deformed CTV structures. DVH metrics were evaluated between the planned and simulated cumulative dose distributions using two treatment techniques: tangential volumetric modulated arc therapy (tVMAT) and conventional 3D-conformal radiotherapy (3D-CRT). Results Based on the HD95 values, the variations in CTV shape and position were enclosed by the 5 mm CTV-PTV margin in 85% of treatment fractions using complementary CBCT and SGRT setup. A residual error of 8.6 mm was observed between the initial SGRT setup and CBCT setup. The median CTV V95% coverage was 98.1% (range 93.1–99.8%) with tVMAT and 98.2% (range 84.5–99.7%) with 3D-CRT techniques with CBCT setup. With the initial SGRT-only setup, the corresponding coverages were 96.3% (range 92.6–99.4%) and 96.6% (range 84.2–99.4%), respectively. However, a considerable bias in vertical residual error between initial SGRT setup and CBCT setup was observed. Clinically relevant changes between the planned and cumulative doses to organs-at-risk (OARs) were not observed. Conclusions The CTV-to-PTV margin should not be reduced below 5 mm even with daily CBCT setup. Both tVMAT and 3D-CRT techniques were robust in terms of dose coverage to the target and OARs. Based on the shifts between setup methods, CBCT setup is recommended as a complementary method with SGRT.https://doi.org/10.1186/s13014-024-02418-5Setup marginSetup uncertaintyTissue deformationsVMATCBCT |
spellingShingle | M. Mankinen T. Virén J. Seppälä T. Koivumäki Interfractional variation in whole-breast VMAT irradiation: a dosimetric study with complementary SGRT and CBCT patient setup Radiation Oncology Setup margin Setup uncertainty Tissue deformations VMAT CBCT |
title | Interfractional variation in whole-breast VMAT irradiation: a dosimetric study with complementary SGRT and CBCT patient setup |
title_full | Interfractional variation in whole-breast VMAT irradiation: a dosimetric study with complementary SGRT and CBCT patient setup |
title_fullStr | Interfractional variation in whole-breast VMAT irradiation: a dosimetric study with complementary SGRT and CBCT patient setup |
title_full_unstemmed | Interfractional variation in whole-breast VMAT irradiation: a dosimetric study with complementary SGRT and CBCT patient setup |
title_short | Interfractional variation in whole-breast VMAT irradiation: a dosimetric study with complementary SGRT and CBCT patient setup |
title_sort | interfractional variation in whole breast vmat irradiation a dosimetric study with complementary sgrt and cbct patient setup |
topic | Setup margin Setup uncertainty Tissue deformations VMAT CBCT |
url | https://doi.org/10.1186/s13014-024-02418-5 |
work_keys_str_mv | AT mmankinen interfractionalvariationinwholebreastvmatirradiationadosimetricstudywithcomplementarysgrtandcbctpatientsetup AT tviren interfractionalvariationinwholebreastvmatirradiationadosimetricstudywithcomplementarysgrtandcbctpatientsetup AT jseppala interfractionalvariationinwholebreastvmatirradiationadosimetricstudywithcomplementarysgrtandcbctpatientsetup AT tkoivumaki interfractionalvariationinwholebreastvmatirradiationadosimetricstudywithcomplementarysgrtandcbctpatientsetup |