Numerical Analysis of Refrigerant Flow in Different Types Of Capillary Tubes Used R1270

The capillary tube is a common expansion device used in small-sized refrigeration and air-conditioning systems. The main focus lies on the analysis of the refrigerant flow behavior along the capillary tube with different shapes (straight-coiled-serpentine) as well as using alternative (R1270) wit...

Full description

Bibliographic Details
Main Author: Haider Ali Hussen
Format: Article
Language:Arabic
Published: Mustansiriyah University/College of Engineering 2013-12-01
Series:Journal of Engineering and Sustainable Development
Subjects:
Online Access:https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/1020
_version_ 1797984922052329472
author Haider Ali Hussen
author_facet Haider Ali Hussen
author_sort Haider Ali Hussen
collection DOAJ
description The capillary tube is a common expansion device used in small-sized refrigeration and air-conditioning systems. The main focus lies on the analysis of the refrigerant flow behavior along the capillary tube with different shapes (straight-coiled-serpentine) as well as using alternative (R1270) with different geometrical parameters by using a commercial code FORTRAN power station for the simulation. Capillary geometrical parameters will include diameter, coiled diameter, and curve diameter. Results showed that when capillary tube internal diameter increases from 1.4 mm to 1.8 mm. Straight tube length increases from (1.2978m) to (4.8738m) with ratio (73.37%) , Coiled tube length increases from (0.589m) to (1.958m) with ratio (69.91%) at coiled diameter (dd=10mm) ,and The serpentine tube length increases from (0.859m) to (2.671m) with ratio (67.84%) at curve radius ( )or curve diameter (dr=10mm).. The ideal capillary tube type is coiled. Because length decrease with a comparison between straight and serpentine.
first_indexed 2024-04-11T07:10:33Z
format Article
id doaj.art-d29dd106cd8744828cb1e40bc99f443e
institution Directory Open Access Journal
issn 2520-0917
2520-0925
language Arabic
last_indexed 2024-04-11T07:10:33Z
publishDate 2013-12-01
publisher Mustansiriyah University/College of Engineering
record_format Article
series Journal of Engineering and Sustainable Development
spelling doaj.art-d29dd106cd8744828cb1e40bc99f443e2022-12-22T04:38:14ZaraMustansiriyah University/College of EngineeringJournal of Engineering and Sustainable Development2520-09172520-09252013-12-01176Numerical Analysis of Refrigerant Flow in Different Types Of Capillary Tubes Used R1270Haider Ali Hussen0Mechanical Engineering Department, Mustansiriyah University, Baghdad, Iraq The capillary tube is a common expansion device used in small-sized refrigeration and air-conditioning systems. The main focus lies on the analysis of the refrigerant flow behavior along the capillary tube with different shapes (straight-coiled-serpentine) as well as using alternative (R1270) with different geometrical parameters by using a commercial code FORTRAN power station for the simulation. Capillary geometrical parameters will include diameter, coiled diameter, and curve diameter. Results showed that when capillary tube internal diameter increases from 1.4 mm to 1.8 mm. Straight tube length increases from (1.2978m) to (4.8738m) with ratio (73.37%) , Coiled tube length increases from (0.589m) to (1.958m) with ratio (69.91%) at coiled diameter (dd=10mm) ,and The serpentine tube length increases from (0.859m) to (2.671m) with ratio (67.84%) at curve radius ( )or curve diameter (dr=10mm).. The ideal capillary tube type is coiled. Because length decrease with a comparison between straight and serpentine. https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/1020CoiledSerpentineCapillary tubeAdiabaticRefrigerantsFlow
spellingShingle Haider Ali Hussen
Numerical Analysis of Refrigerant Flow in Different Types Of Capillary Tubes Used R1270
Journal of Engineering and Sustainable Development
Coiled
Serpentine
Capillary tube
Adiabatic
Refrigerants
Flow
title Numerical Analysis of Refrigerant Flow in Different Types Of Capillary Tubes Used R1270
title_full Numerical Analysis of Refrigerant Flow in Different Types Of Capillary Tubes Used R1270
title_fullStr Numerical Analysis of Refrigerant Flow in Different Types Of Capillary Tubes Used R1270
title_full_unstemmed Numerical Analysis of Refrigerant Flow in Different Types Of Capillary Tubes Used R1270
title_short Numerical Analysis of Refrigerant Flow in Different Types Of Capillary Tubes Used R1270
title_sort numerical analysis of refrigerant flow in different types of capillary tubes used r1270
topic Coiled
Serpentine
Capillary tube
Adiabatic
Refrigerants
Flow
url https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/1020
work_keys_str_mv AT haideralihussen numericalanalysisofrefrigerantflowindifferenttypesofcapillarytubesusedr1270