A Conductometric Urea Biosensor by Direct Immobilization of Urease on Pt Electrode
Urease was immobilized on platinum electrode both by chemical binding and electropolymerization.The conductometric urea biosensor thus prepared showed a detection limit of 4.9×10-5 M and linear dynamic range from 4.9×10-5 to 5.8×10-3 M for urea concentration when the enzyme is covalently immobilized...
Main Authors: | Hedayatollah Ghourchian, Ahmad Moulaie Rad, Hossein Elyasvandi |
---|---|
Format: | Article |
Language: | English |
Published: |
Iranian Institute of Research and Development in Chemical Industries (IRDCI)-ACECR
2004-12-01
|
Series: | Iranian Journal of Chemistry & Chemical Engineering |
Subjects: | |
Online Access: | http://www.ijcce.ac.ir/article_8139_e47ede4f511924512112442635373c38.pdf |
Similar Items
-
INVESTIGATION AND OPTIMIZATION OF REACTIVATION OF UREASE BIOSENSOR FOR HEAVY METALS INHIBITION ANALYSIS
by: S. R., et al.
Published: (2015-12-01) -
Potentiometric Urea Biosensor Based on an Immobilised Fullerene-Urease Bio-Conjugate
by: Kasra Saeedfar, et al.
Published: (2013-12-01) -
ENZYME CONDUCTOMETRIC BIOSENSOR FOR FRUCTOSE DETERMINATION
by: O. Y. Dudchenko, et al.
Published: (2013-06-01) -
Efficient Portable Urea Biosensor Based on Urease Immobilized Membrane for Monitoring of Physiological Fluids
by: Jee Young Kim, et al.
Published: (2020-12-01) -
A Conductometric Indium Oxide Semiconducting Nanoparticle Enzymatic Biosensor Array
by: Tianhong Cui, et al.
Published: (2011-09-01)