Logicon: A third eye for caries detection

Objectives: To evaluate and compare the diagnostic value of computer-assisted caries detector Logicon with other diagnostic methods. Materials and Methods: This study was conducted on 300 proximal surfaces corresponding to 150 posterior teeth. The diagnostic techniques employed comprised an ORIx 65...

Full description

Bibliographic Details
Main Authors: Mohammed Najmuddin, Girish Katti, Syeda Arshiya Ara, Safeena Abdul Khader Saheb, Amit Byatnal, Mohammed Wahajuddin
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2018-01-01
Series:Journal of Indian Academy of Oral Medicine and Radiology
Subjects:
Online Access:http://www.jiaomr.in/article.asp?issn=0972-1363;year=2018;volume=30;issue=4;spage=380;epage=384;aulast=Najmuddin
_version_ 1818236874960928768
author Mohammed Najmuddin
Girish Katti
Syeda Arshiya Ara
Safeena Abdul Khader Saheb
Amit Byatnal
Mohammed Wahajuddin
author_facet Mohammed Najmuddin
Girish Katti
Syeda Arshiya Ara
Safeena Abdul Khader Saheb
Amit Byatnal
Mohammed Wahajuddin
author_sort Mohammed Najmuddin
collection DOAJ
description Objectives: To evaluate and compare the diagnostic value of computer-assisted caries detector Logicon with other diagnostic methods. Materials and Methods: This study was conducted on 300 proximal surfaces corresponding to 150 posterior teeth. The diagnostic techniques employed comprised an ORIx 65 kV intraoral radiodiagnostic apparatus, Trophy RVG system in normal mode, and in combination with a caries diagnosis assisting program by Logicon. The same X-ray source was used for the entire study, followed by comparison with histological sections of the teeth used which were observed under light microscope. The positive and negative predictive values, sensitivity, specificity, and probability ratio were calculated. Results: Application of computer-assisted caries detector Logicon increased sensitivity for the cases where caries was extending into the dentin. In contrast, conventional radiography showed a higher specificity and positive predictive value, whereas the negative predictive values were the same for both techniques. Conclusion: This study has demonstrated that Logicon Caries Detector can enable dentists to find 49% more cases of caries penetrating the dentin than they were able to find without it.
first_indexed 2024-12-12T12:16:48Z
format Article
id doaj.art-d2b32f04dedd466e9b728f79ee693c53
institution Directory Open Access Journal
issn 0972-1363
language English
last_indexed 2024-12-12T12:16:48Z
publishDate 2018-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Journal of Indian Academy of Oral Medicine and Radiology
spelling doaj.art-d2b32f04dedd466e9b728f79ee693c532022-12-22T00:24:46ZengWolters Kluwer Medknow PublicationsJournal of Indian Academy of Oral Medicine and Radiology0972-13632018-01-0130438038410.4103/jiaomr.jiaomr_83_18Logicon: A third eye for caries detectionMohammed NajmuddinGirish KattiSyeda Arshiya AraSafeena Abdul Khader SahebAmit ByatnalMohammed WahajuddinObjectives: To evaluate and compare the diagnostic value of computer-assisted caries detector Logicon with other diagnostic methods. Materials and Methods: This study was conducted on 300 proximal surfaces corresponding to 150 posterior teeth. The diagnostic techniques employed comprised an ORIx 65 kV intraoral radiodiagnostic apparatus, Trophy RVG system in normal mode, and in combination with a caries diagnosis assisting program by Logicon. The same X-ray source was used for the entire study, followed by comparison with histological sections of the teeth used which were observed under light microscope. The positive and negative predictive values, sensitivity, specificity, and probability ratio were calculated. Results: Application of computer-assisted caries detector Logicon increased sensitivity for the cases where caries was extending into the dentin. In contrast, conventional radiography showed a higher specificity and positive predictive value, whereas the negative predictive values were the same for both techniques. Conclusion: This study has demonstrated that Logicon Caries Detector can enable dentists to find 49% more cases of caries penetrating the dentin than they were able to find without it.http://www.jiaomr.in/article.asp?issn=0972-1363;year=2018;volume=30;issue=4;spage=380;epage=384;aulast=NajmuddinDigital radiographylogiconproximal caries
spellingShingle Mohammed Najmuddin
Girish Katti
Syeda Arshiya Ara
Safeena Abdul Khader Saheb
Amit Byatnal
Mohammed Wahajuddin
Logicon: A third eye for caries detection
Journal of Indian Academy of Oral Medicine and Radiology
Digital radiography
logicon
proximal caries
title Logicon: A third eye for caries detection
title_full Logicon: A third eye for caries detection
title_fullStr Logicon: A third eye for caries detection
title_full_unstemmed Logicon: A third eye for caries detection
title_short Logicon: A third eye for caries detection
title_sort logicon a third eye for caries detection
topic Digital radiography
logicon
proximal caries
url http://www.jiaomr.in/article.asp?issn=0972-1363;year=2018;volume=30;issue=4;spage=380;epage=384;aulast=Najmuddin
work_keys_str_mv AT mohammednajmuddin logiconathirdeyeforcariesdetection
AT girishkatti logiconathirdeyeforcariesdetection
AT syedaarshiyaara logiconathirdeyeforcariesdetection
AT safeenaabdulkhadersaheb logiconathirdeyeforcariesdetection
AT amitbyatnal logiconathirdeyeforcariesdetection
AT mohammedwahajuddin logiconathirdeyeforcariesdetection