Apexoconnection: A Novel Technique to Determine Working Length

Muslat A Bin Rubaia’an,1 Mohammed AbuHassna,2 Rahaf K AlShahrani,1 Khaled Alghulikah,2 Abdulrahman Dahham Alsaffan3 1College of Dentistry, Riyadh Elm University, Riyadh, Kingdom of Saudi Arabia; 2Restorative Dentistry Department, College of Dentistry, Riyadh Elm University, Riyadh, Kingdom of Saudi...

Full description

Bibliographic Details
Main Authors: Bin Rubaia'an MA, AbuHassna M, AlShahrani RK, Alghulikah K, Dahham Alsaffan A
Format: Article
Language:English
Published: Dove Medical Press 2021-08-01
Series:Clinical, Cosmetic and Investigational Dentistry
Subjects:
Online Access:https://www.dovepress.com/apexoconnection-a-novel-technique-to-determine-working-length-peer-reviewed-fulltext-article-CCIDE
_version_ 1819096598255239168
author Bin Rubaia'an MA
AbuHassna M
AlShahrani RK
Alghulikah K
Dahham Alsaffan A
author_facet Bin Rubaia'an MA
AbuHassna M
AlShahrani RK
Alghulikah K
Dahham Alsaffan A
author_sort Bin Rubaia'an MA
collection DOAJ
description Muslat A Bin Rubaia’an,1 Mohammed AbuHassna,2 Rahaf K AlShahrani,1 Khaled Alghulikah,2 Abdulrahman Dahham Alsaffan3 1College of Dentistry, Riyadh Elm University, Riyadh, Kingdom of Saudi Arabia; 2Restorative Dentistry Department, College of Dentistry, Riyadh Elm University, Riyadh, Kingdom of Saudi Arabia; 3Preventive Dentistry Department, College of Dentistry, Riyadh Elm University, Riyadh, Kingdom of Saudi ArabiaCorrespondence: Muslat A Bin Rubaia’an Tel +966 557020222Email Mislat.BinRubayan@student.Riyadh.edu.saPurpose: The aim of this study was to evaluate and compare the accuracy of working length (WL) determination when using the conventional electronic WL (EWL) technique versus using the novel Apexoconnection technique involving EWL with a connector (EWLc).Materials and Methods: Sixty extracted posterior teeth with a total of 118 root canals were selected for the study. The real WL (RWL) of each canal was verified using a dental microscope under 25.6x magnification. Root canal lengths were measured with an apex locator using the attachment device directly attached to the hand file in the root canal and then adding another hand file as a connector between the attachment device and the file in the root canal. The distance from the file’s stopper to its tip was measured using a digital caliper. Statistical analysis was carried out to analyze the data between experimental groups.Results: The results of the statistical test showed that the differences in the WL determined by either technique and the proper length as determined under the microscope were not statistically significant. The results of the statistical test comparing the groups were also not statistically significant.Conclusion: In this in vitro study, both the novel and conventional techniques were equally accurate for determining WL when compared with the RWL.Keywords: electronic apex locator, electronic working length, endodontics, root canal treatment, working length determination
first_indexed 2024-12-22T00:01:44Z
format Article
id doaj.art-d34639c73bf5458986f0988524686195
institution Directory Open Access Journal
issn 1179-1357
language English
last_indexed 2024-12-22T00:01:44Z
publishDate 2021-08-01
publisher Dove Medical Press
record_format Article
series Clinical, Cosmetic and Investigational Dentistry
spelling doaj.art-d34639c73bf5458986f09885246861952022-12-21T18:45:41ZengDove Medical PressClinical, Cosmetic and Investigational Dentistry1179-13572021-08-01Volume 1335336067980Apexoconnection: A Novel Technique to Determine Working LengthBin Rubaia'an MAAbuHassna MAlShahrani RKAlghulikah KDahham Alsaffan AMuslat A Bin Rubaia’an,1 Mohammed AbuHassna,2 Rahaf K AlShahrani,1 Khaled Alghulikah,2 Abdulrahman Dahham Alsaffan3 1College of Dentistry, Riyadh Elm University, Riyadh, Kingdom of Saudi Arabia; 2Restorative Dentistry Department, College of Dentistry, Riyadh Elm University, Riyadh, Kingdom of Saudi Arabia; 3Preventive Dentistry Department, College of Dentistry, Riyadh Elm University, Riyadh, Kingdom of Saudi ArabiaCorrespondence: Muslat A Bin Rubaia’an Tel +966 557020222Email Mislat.BinRubayan@student.Riyadh.edu.saPurpose: The aim of this study was to evaluate and compare the accuracy of working length (WL) determination when using the conventional electronic WL (EWL) technique versus using the novel Apexoconnection technique involving EWL with a connector (EWLc).Materials and Methods: Sixty extracted posterior teeth with a total of 118 root canals were selected for the study. The real WL (RWL) of each canal was verified using a dental microscope under 25.6x magnification. Root canal lengths were measured with an apex locator using the attachment device directly attached to the hand file in the root canal and then adding another hand file as a connector between the attachment device and the file in the root canal. The distance from the file’s stopper to its tip was measured using a digital caliper. Statistical analysis was carried out to analyze the data between experimental groups.Results: The results of the statistical test showed that the differences in the WL determined by either technique and the proper length as determined under the microscope were not statistically significant. The results of the statistical test comparing the groups were also not statistically significant.Conclusion: In this in vitro study, both the novel and conventional techniques were equally accurate for determining WL when compared with the RWL.Keywords: electronic apex locator, electronic working length, endodontics, root canal treatment, working length determinationhttps://www.dovepress.com/apexoconnection-a-novel-technique-to-determine-working-length-peer-reviewed-fulltext-article-CCIDEelectronic apex locatorelectronic working lengthendodonticsroot canal treatmentworking length determination.
spellingShingle Bin Rubaia'an MA
AbuHassna M
AlShahrani RK
Alghulikah K
Dahham Alsaffan A
Apexoconnection: A Novel Technique to Determine Working Length
Clinical, Cosmetic and Investigational Dentistry
electronic apex locator
electronic working length
endodontics
root canal treatment
working length determination.
title Apexoconnection: A Novel Technique to Determine Working Length
title_full Apexoconnection: A Novel Technique to Determine Working Length
title_fullStr Apexoconnection: A Novel Technique to Determine Working Length
title_full_unstemmed Apexoconnection: A Novel Technique to Determine Working Length
title_short Apexoconnection: A Novel Technique to Determine Working Length
title_sort apexoconnection a novel technique to determine working length
topic electronic apex locator
electronic working length
endodontics
root canal treatment
working length determination.
url https://www.dovepress.com/apexoconnection-a-novel-technique-to-determine-working-length-peer-reviewed-fulltext-article-CCIDE
work_keys_str_mv AT binrubaiaanma apexoconnectionanoveltechniquetodetermineworkinglength
AT abuhassnam apexoconnectionanoveltechniquetodetermineworkinglength
AT alshahranirk apexoconnectionanoveltechniquetodetermineworkinglength
AT alghulikahk apexoconnectionanoveltechniquetodetermineworkinglength
AT dahhamalsaffana apexoconnectionanoveltechniquetodetermineworkinglength