The role of dual-energy computed tomography in the diagnosis of gout and other crystalline arthropathies: A review
The importance of dual-energy computed tomography in the diagnosis of gout, the principles of dual-energy computed tomography, the accuracy of the methodology, and the types of artifacts are discussed in this study. The possible dependence of the presence of deposits of sodium monourate on other cli...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Eco-Vector
2023-07-01
|
Series: | Digital Diagnostics |
Subjects: | |
Online Access: | https://jdigitaldiagnostics.com/DD/article/viewFile/322758/pdf |
_version_ | 1797685733768560640 |
---|---|
author | Maria V. Onoyko Elena A. Mershina Olga A. Georginova Maria L. Plotnikova Alexandra V. Panyukova Valentin E. Sinitsyn |
author_facet | Maria V. Onoyko Elena A. Mershina Olga A. Georginova Maria L. Plotnikova Alexandra V. Panyukova Valentin E. Sinitsyn |
author_sort | Maria V. Onoyko |
collection | DOAJ |
description | The importance of dual-energy computed tomography in the diagnosis of gout, the principles of dual-energy computed tomography, the accuracy of the methodology, and the types of artifacts are discussed in this study. The possible dependence of the presence of deposits of sodium monourate on other clinical data and the role of dual-energy computed tomography in the differential diagnosis of other crystalline arthropathies are considered.
The dual-energy computed tomography has several advantages, including noninvasiveness, speed of execution, and a significant reduction in the risk of iatrogenic consequences compared with diagnostic arthrocentesis, which is the gold standard in diagnosing gout. Dual-energy computed tomography can accomplish gout detection, treatment, and differential diagnosis. |
first_indexed | 2024-03-12T00:55:36Z |
format | Article |
id | doaj.art-d3c9cb45f2b344eb9cf81813951c69ae |
institution | Directory Open Access Journal |
issn | 2712-8490 2712-8962 |
language | English |
last_indexed | 2024-03-12T00:55:36Z |
publishDate | 2023-07-01 |
publisher | Eco-Vector |
record_format | Article |
series | Digital Diagnostics |
spelling | doaj.art-d3c9cb45f2b344eb9cf81813951c69ae2023-09-14T14:08:00ZengEco-VectorDigital Diagnostics2712-84902712-89622023-07-014219721310.17816/DD32275876483The role of dual-energy computed tomography in the diagnosis of gout and other crystalline arthropathies: A reviewMaria V. Onoyko0https://orcid.org/0000-0002-7727-3360Elena A. Mershina1https://orcid.org/0000-0002-1266-4926Olga A. Georginova2https://orcid.org/0000-0002-7542-8189Maria L. Plotnikova3https://orcid.org/0000-0001-7533-9867Alexandra V. Panyukova4https://orcid.org/0000-0002-5367-280XValentin E. Sinitsyn5https://orcid.org/0000-0002-5649-2193Lomonosov Moscow State UniversityLomonosov Moscow State UniversityLomonosov Moscow State UniversityLomonosov Moscow State UniversityLomonosov Moscow State UniversityLomonosov Moscow State UniversityThe importance of dual-energy computed tomography in the diagnosis of gout, the principles of dual-energy computed tomography, the accuracy of the methodology, and the types of artifacts are discussed in this study. The possible dependence of the presence of deposits of sodium monourate on other clinical data and the role of dual-energy computed tomography in the differential diagnosis of other crystalline arthropathies are considered. The dual-energy computed tomography has several advantages, including noninvasiveness, speed of execution, and a significant reduction in the risk of iatrogenic consequences compared with diagnostic arthrocentesis, which is the gold standard in diagnosing gout. Dual-energy computed tomography can accomplish gout detection, treatment, and differential diagnosis.https://jdigitaldiagnostics.com/DD/article/viewFile/322758/pdfcalcium pyrophosphatecrystal arthropathiesdiagnostic imagingdual-energy computed tomographygout |
spellingShingle | Maria V. Onoyko Elena A. Mershina Olga A. Georginova Maria L. Plotnikova Alexandra V. Panyukova Valentin E. Sinitsyn The role of dual-energy computed tomography in the diagnosis of gout and other crystalline arthropathies: A review Digital Diagnostics calcium pyrophosphate crystal arthropathies diagnostic imaging dual-energy computed tomography gout |
title | The role of dual-energy computed tomography in the diagnosis of gout and other crystalline arthropathies: A review |
title_full | The role of dual-energy computed tomography in the diagnosis of gout and other crystalline arthropathies: A review |
title_fullStr | The role of dual-energy computed tomography in the diagnosis of gout and other crystalline arthropathies: A review |
title_full_unstemmed | The role of dual-energy computed tomography in the diagnosis of gout and other crystalline arthropathies: A review |
title_short | The role of dual-energy computed tomography in the diagnosis of gout and other crystalline arthropathies: A review |
title_sort | role of dual energy computed tomography in the diagnosis of gout and other crystalline arthropathies a review |
topic | calcium pyrophosphate crystal arthropathies diagnostic imaging dual-energy computed tomography gout |
url | https://jdigitaldiagnostics.com/DD/article/viewFile/322758/pdf |
work_keys_str_mv | AT mariavonoyko theroleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview AT elenaamershina theroleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview AT olgaageorginova theroleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview AT marialplotnikova theroleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview AT alexandravpanyukova theroleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview AT valentinesinitsyn theroleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview AT mariavonoyko roleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview AT elenaamershina roleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview AT olgaageorginova roleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview AT marialplotnikova roleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview AT alexandravpanyukova roleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview AT valentinesinitsyn roleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview |