The role of dual-energy computed tomography in the diagnosis of gout and other crystalline arthropathies: A review

The importance of dual-energy computed tomography in the diagnosis of gout, the principles of dual-energy computed tomography, the accuracy of the methodology, and the types of artifacts are discussed in this study. The possible dependence of the presence of deposits of sodium monourate on other cli...

Full description

Bibliographic Details
Main Authors: Maria V. Onoyko, Elena A. Mershina, Olga A. Georginova, Maria L. Plotnikova, Alexandra V. Panyukova, Valentin E. Sinitsyn
Format: Article
Language:English
Published: Eco-Vector 2023-07-01
Series:Digital Diagnostics
Subjects:
Online Access:https://jdigitaldiagnostics.com/DD/article/viewFile/322758/pdf
_version_ 1797685733768560640
author Maria V. Onoyko
Elena A. Mershina
Olga A. Georginova
Maria L. Plotnikova
Alexandra V. Panyukova
Valentin E. Sinitsyn
author_facet Maria V. Onoyko
Elena A. Mershina
Olga A. Georginova
Maria L. Plotnikova
Alexandra V. Panyukova
Valentin E. Sinitsyn
author_sort Maria V. Onoyko
collection DOAJ
description The importance of dual-energy computed tomography in the diagnosis of gout, the principles of dual-energy computed tomography, the accuracy of the methodology, and the types of artifacts are discussed in this study. The possible dependence of the presence of deposits of sodium monourate on other clinical data and the role of dual-energy computed tomography in the differential diagnosis of other crystalline arthropathies are considered. The dual-energy computed tomography has several advantages, including noninvasiveness, speed of execution, and a significant reduction in the risk of iatrogenic consequences compared with diagnostic arthrocentesis, which is the gold standard in diagnosing gout. Dual-energy computed tomography can accomplish gout detection, treatment, and differential diagnosis.
first_indexed 2024-03-12T00:55:36Z
format Article
id doaj.art-d3c9cb45f2b344eb9cf81813951c69ae
institution Directory Open Access Journal
issn 2712-8490
2712-8962
language English
last_indexed 2024-03-12T00:55:36Z
publishDate 2023-07-01
publisher Eco-Vector
record_format Article
series Digital Diagnostics
spelling doaj.art-d3c9cb45f2b344eb9cf81813951c69ae2023-09-14T14:08:00ZengEco-VectorDigital Diagnostics2712-84902712-89622023-07-014219721310.17816/DD32275876483The role of dual-energy computed tomography in the diagnosis of gout and other crystalline arthropathies: A reviewMaria V. Onoyko0https://orcid.org/0000-0002-7727-3360Elena A. Mershina1https://orcid.org/0000-0002-1266-4926Olga A. Georginova2https://orcid.org/0000-0002-7542-8189Maria L. Plotnikova3https://orcid.org/0000-0001-7533-9867Alexandra V. Panyukova4https://orcid.org/0000-0002-5367-280XValentin E. Sinitsyn5https://orcid.org/0000-0002-5649-2193Lomonosov Moscow State UniversityLomonosov Moscow State UniversityLomonosov Moscow State UniversityLomonosov Moscow State UniversityLomonosov Moscow State UniversityLomonosov Moscow State UniversityThe importance of dual-energy computed tomography in the diagnosis of gout, the principles of dual-energy computed tomography, the accuracy of the methodology, and the types of artifacts are discussed in this study. The possible dependence of the presence of deposits of sodium monourate on other clinical data and the role of dual-energy computed tomography in the differential diagnosis of other crystalline arthropathies are considered. The dual-energy computed tomography has several advantages, including noninvasiveness, speed of execution, and a significant reduction in the risk of iatrogenic consequences compared with diagnostic arthrocentesis, which is the gold standard in diagnosing gout. Dual-energy computed tomography can accomplish gout detection, treatment, and differential diagnosis.https://jdigitaldiagnostics.com/DD/article/viewFile/322758/pdfcalcium pyrophosphatecrystal arthropathiesdiagnostic imagingdual-energy computed tomographygout
spellingShingle Maria V. Onoyko
Elena A. Mershina
Olga A. Georginova
Maria L. Plotnikova
Alexandra V. Panyukova
Valentin E. Sinitsyn
The role of dual-energy computed tomography in the diagnosis of gout and other crystalline arthropathies: A review
Digital Diagnostics
calcium pyrophosphate
crystal arthropathies
diagnostic imaging
dual-energy computed tomography
gout
title The role of dual-energy computed tomography in the diagnosis of gout and other crystalline arthropathies: A review
title_full The role of dual-energy computed tomography in the diagnosis of gout and other crystalline arthropathies: A review
title_fullStr The role of dual-energy computed tomography in the diagnosis of gout and other crystalline arthropathies: A review
title_full_unstemmed The role of dual-energy computed tomography in the diagnosis of gout and other crystalline arthropathies: A review
title_short The role of dual-energy computed tomography in the diagnosis of gout and other crystalline arthropathies: A review
title_sort role of dual energy computed tomography in the diagnosis of gout and other crystalline arthropathies a review
topic calcium pyrophosphate
crystal arthropathies
diagnostic imaging
dual-energy computed tomography
gout
url https://jdigitaldiagnostics.com/DD/article/viewFile/322758/pdf
work_keys_str_mv AT mariavonoyko theroleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview
AT elenaamershina theroleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview
AT olgaageorginova theroleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview
AT marialplotnikova theroleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview
AT alexandravpanyukova theroleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview
AT valentinesinitsyn theroleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview
AT mariavonoyko roleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview
AT elenaamershina roleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview
AT olgaageorginova roleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview
AT marialplotnikova roleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview
AT alexandravpanyukova roleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview
AT valentinesinitsyn roleofdualenergycomputedtomographyinthediagnosisofgoutandothercrystallinearthropathiesareview