Pathological evaluation of a fluoropolymer-based drug-eluting stent in an arteriovenous graft outflow venous stenosis

A fluoropolymer-based drug-eluting stent was implanted in an arteriovenous graft outflow venous stenosis. Two and a half years later, due to a local infection, the stent was removed surgically, and a pathological evaluation was conducted. The stent struts exhibited partial endothelial cell coverage,...

Full description

Bibliographic Details
Main Authors: Kotaro Suemitsu, MD, PhD, Osamu Iida, MD, PhD, Sho Torii, MD, PhD, Yosuke Hata, MD, Taku Toyoshima, MD, Masaaki Izumi, MD, PhD
Format: Article
Language:English
Published: Elsevier 2024-06-01
Series:Journal of Vascular Surgery Cases and Innovative Techniques
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2468428724000315
_version_ 1797262881506459648
author Kotaro Suemitsu, MD, PhD
Osamu Iida, MD, PhD
Sho Torii, MD, PhD
Yosuke Hata, MD
Taku Toyoshima, MD
Masaaki Izumi, MD, PhD
author_facet Kotaro Suemitsu, MD, PhD
Osamu Iida, MD, PhD
Sho Torii, MD, PhD
Yosuke Hata, MD
Taku Toyoshima, MD
Masaaki Izumi, MD, PhD
author_sort Kotaro Suemitsu, MD, PhD
collection DOAJ
description A fluoropolymer-based drug-eluting stent was implanted in an arteriovenous graft outflow venous stenosis. Two and a half years later, due to a local infection, the stent was removed surgically, and a pathological evaluation was conducted. The stent struts exhibited partial endothelial cell coverage, with the remaining surface predominantly covered by fibrin. Notably, there was no evidence of restenosis or aneurysmal change.
first_indexed 2024-04-25T00:04:09Z
format Article
id doaj.art-d447accfa75647739f3b386df33c5adf
institution Directory Open Access Journal
issn 2468-4287
language English
last_indexed 2024-04-25T00:04:09Z
publishDate 2024-06-01
publisher Elsevier
record_format Article
series Journal of Vascular Surgery Cases and Innovative Techniques
spelling doaj.art-d447accfa75647739f3b386df33c5adf2024-03-14T06:15:43ZengElsevierJournal of Vascular Surgery Cases and Innovative Techniques2468-42872024-06-01103101447Pathological evaluation of a fluoropolymer-based drug-eluting stent in an arteriovenous graft outflow venous stenosisKotaro Suemitsu, MD, PhD0Osamu Iida, MD, PhD1Sho Torii, MD, PhD2Yosuke Hata, MD3Taku Toyoshima, MD4Masaaki Izumi, MD, PhD5Division of Kidney and Dialysis, Department of Internal Medicine, Kansai Rosai Hospital, Amagasaki, Japan; Correspondence: Kotaro Suemitsu, MD, PhD, Division of Kidney and Dialysis, Department of Internal Medicine, Kansai Rosai Hospital, 3-1-69 Inabasou, Amagasaki, Hyogo 660-8511, JapanCardiovascular Division, Osaka Police Hospital, Osaka, JapanDepartment of Cardiology, Tokai University School of Medicine, Isehara, JapanCardiovascular Center, Kansai Rosai Hospital, Amagasaki, JapanCardiovascular Division, Osaka Police Hospital, Osaka, JapanDivision of Kidney and Dialysis, Department of Internal Medicine, Kansai Rosai Hospital, Amagasaki, JapanA fluoropolymer-based drug-eluting stent was implanted in an arteriovenous graft outflow venous stenosis. Two and a half years later, due to a local infection, the stent was removed surgically, and a pathological evaluation was conducted. The stent struts exhibited partial endothelial cell coverage, with the remaining surface predominantly covered by fibrin. Notably, there was no evidence of restenosis or aneurysmal change.http://www.sciencedirect.com/science/article/pii/S2468428724000315Arteriovenous graftEluviaFluoropolymer-based drug-eluting stentHemodialysisVascular access
spellingShingle Kotaro Suemitsu, MD, PhD
Osamu Iida, MD, PhD
Sho Torii, MD, PhD
Yosuke Hata, MD
Taku Toyoshima, MD
Masaaki Izumi, MD, PhD
Pathological evaluation of a fluoropolymer-based drug-eluting stent in an arteriovenous graft outflow venous stenosis
Journal of Vascular Surgery Cases and Innovative Techniques
Arteriovenous graft
Eluvia
Fluoropolymer-based drug-eluting stent
Hemodialysis
Vascular access
title Pathological evaluation of a fluoropolymer-based drug-eluting stent in an arteriovenous graft outflow venous stenosis
title_full Pathological evaluation of a fluoropolymer-based drug-eluting stent in an arteriovenous graft outflow venous stenosis
title_fullStr Pathological evaluation of a fluoropolymer-based drug-eluting stent in an arteriovenous graft outflow venous stenosis
title_full_unstemmed Pathological evaluation of a fluoropolymer-based drug-eluting stent in an arteriovenous graft outflow venous stenosis
title_short Pathological evaluation of a fluoropolymer-based drug-eluting stent in an arteriovenous graft outflow venous stenosis
title_sort pathological evaluation of a fluoropolymer based drug eluting stent in an arteriovenous graft outflow venous stenosis
topic Arteriovenous graft
Eluvia
Fluoropolymer-based drug-eluting stent
Hemodialysis
Vascular access
url http://www.sciencedirect.com/science/article/pii/S2468428724000315
work_keys_str_mv AT kotarosuemitsumdphd pathologicalevaluationofafluoropolymerbaseddrugelutingstentinanarteriovenousgraftoutflowvenousstenosis
AT osamuiidamdphd pathologicalevaluationofafluoropolymerbaseddrugelutingstentinanarteriovenousgraftoutflowvenousstenosis
AT shotoriimdphd pathologicalevaluationofafluoropolymerbaseddrugelutingstentinanarteriovenousgraftoutflowvenousstenosis
AT yosukehatamd pathologicalevaluationofafluoropolymerbaseddrugelutingstentinanarteriovenousgraftoutflowvenousstenosis
AT takutoyoshimamd pathologicalevaluationofafluoropolymerbaseddrugelutingstentinanarteriovenousgraftoutflowvenousstenosis
AT masaakiizumimdphd pathologicalevaluationofafluoropolymerbaseddrugelutingstentinanarteriovenousgraftoutflowvenousstenosis