UJI KELAYAKAN PESAWAT SINAR-X TERHADAP PROYEKSI PA (POSTERO-ANTERIOR) DAN LAT (LATERAL) PADA TEKNIK PEMERIKSAAN FOTO THORAX

Research has been conducted to determine feasibility test of the X-ray planePA and LAT projections on chest x-ray techniques. The study using a water phantom object as a substitute for patients with variations in interval distance ofthe  100-180 cm. Measurement of radiation dose X-rays performed fiv...

Full description

Bibliographic Details
Main Authors: Kadek Miniati, Gusti Ngurah Sutapa, I Wayan Balik Sudarsana
Format: Article
Language:English
Published: Universitas Udayana 2017-02-01
Series:Buletin Fisika
Online Access:https://ojs.unud.ac.id/index.php/buletinfisika/article/view/31557
_version_ 1819327145514631168
author Kadek Miniati
Gusti Ngurah Sutapa
I Wayan Balik Sudarsana
author_facet Kadek Miniati
Gusti Ngurah Sutapa
I Wayan Balik Sudarsana
author_sort Kadek Miniati
collection DOAJ
description Research has been conducted to determine feasibility test of the X-ray planePA and LAT projections on chest x-ray techniques. The study using a water phantom object as a substitute for patients with variations in interval distance ofthe  100-180 cm. Measurement of radiation dose X-rays performed five repetitions , measurable doses had be read on the device electrometer. Exposition factors to the PA projection using a tube voltage of 75 kV, current and time of 3,2 mAs, the irradiation field areaof (30 x 30) cm2.For the LAT projection tube voltage of 80 kV, current and time of 6,3 mAs, and the irradiation field area of (20 x 30) cm2. It the study of the radiation dose X-ray plane projection PA and LAT is optimal is below the limit value at the level of dosage guidelines BAPETEN No 08 of 2011. Obtained PA projections are below the value of 0,4 mGy while LAT projection is below the value of 1,5 mGy. The radiation dose X-rays plane using a variation of 100-180 cm distance is still below the dose limit values ??, thus meeting the objectives anssurance quality and quality control.
first_indexed 2024-12-24T13:06:11Z
format Article
id doaj.art-d4ddc0018df54879ad37f147fdd6f2d9
institution Directory Open Access Journal
issn 1411-4690
2580-9733
language English
last_indexed 2024-12-24T13:06:11Z
publishDate 2017-02-01
publisher Universitas Udayana
record_format Article
series Buletin Fisika
spelling doaj.art-d4ddc0018df54879ad37f147fdd6f2d92022-12-21T16:54:00ZengUniversitas UdayanaBuletin Fisika1411-46902580-97332017-02-01181273110.24843/BF.2017.v18.i01.p0531557UJI KELAYAKAN PESAWAT SINAR-X TERHADAP PROYEKSI PA (POSTERO-ANTERIOR) DAN LAT (LATERAL) PADA TEKNIK PEMERIKSAAN FOTO THORAXKadek Miniati0Gusti Ngurah Sutapa1I Wayan Balik Sudarsana2Udayana UniversityUdayana UniversityUdayana UniversityResearch has been conducted to determine feasibility test of the X-ray planePA and LAT projections on chest x-ray techniques. The study using a water phantom object as a substitute for patients with variations in interval distance ofthe  100-180 cm. Measurement of radiation dose X-rays performed five repetitions , measurable doses had be read on the device electrometer. Exposition factors to the PA projection using a tube voltage of 75 kV, current and time of 3,2 mAs, the irradiation field areaof (30 x 30) cm2.For the LAT projection tube voltage of 80 kV, current and time of 6,3 mAs, and the irradiation field area of (20 x 30) cm2. It the study of the radiation dose X-ray plane projection PA and LAT is optimal is below the limit value at the level of dosage guidelines BAPETEN No 08 of 2011. Obtained PA projections are below the value of 0,4 mGy while LAT projection is below the value of 1,5 mGy. The radiation dose X-rays plane using a variation of 100-180 cm distance is still below the dose limit values ??, thus meeting the objectives anssurance quality and quality control.https://ojs.unud.ac.id/index.php/buletinfisika/article/view/31557
spellingShingle Kadek Miniati
Gusti Ngurah Sutapa
I Wayan Balik Sudarsana
UJI KELAYAKAN PESAWAT SINAR-X TERHADAP PROYEKSI PA (POSTERO-ANTERIOR) DAN LAT (LATERAL) PADA TEKNIK PEMERIKSAAN FOTO THORAX
Buletin Fisika
title UJI KELAYAKAN PESAWAT SINAR-X TERHADAP PROYEKSI PA (POSTERO-ANTERIOR) DAN LAT (LATERAL) PADA TEKNIK PEMERIKSAAN FOTO THORAX
title_full UJI KELAYAKAN PESAWAT SINAR-X TERHADAP PROYEKSI PA (POSTERO-ANTERIOR) DAN LAT (LATERAL) PADA TEKNIK PEMERIKSAAN FOTO THORAX
title_fullStr UJI KELAYAKAN PESAWAT SINAR-X TERHADAP PROYEKSI PA (POSTERO-ANTERIOR) DAN LAT (LATERAL) PADA TEKNIK PEMERIKSAAN FOTO THORAX
title_full_unstemmed UJI KELAYAKAN PESAWAT SINAR-X TERHADAP PROYEKSI PA (POSTERO-ANTERIOR) DAN LAT (LATERAL) PADA TEKNIK PEMERIKSAAN FOTO THORAX
title_short UJI KELAYAKAN PESAWAT SINAR-X TERHADAP PROYEKSI PA (POSTERO-ANTERIOR) DAN LAT (LATERAL) PADA TEKNIK PEMERIKSAAN FOTO THORAX
title_sort uji kelayakan pesawat sinar x terhadap proyeksi pa postero anterior dan lat lateral pada teknik pemeriksaan foto thorax
url https://ojs.unud.ac.id/index.php/buletinfisika/article/view/31557
work_keys_str_mv AT kadekminiati ujikelayakanpesawatsinarxterhadapproyeksipaposteroanteriordanlatlateralpadateknikpemeriksaanfotothorax
AT gustingurahsutapa ujikelayakanpesawatsinarxterhadapproyeksipaposteroanteriordanlatlateralpadateknikpemeriksaanfotothorax
AT iwayanbaliksudarsana ujikelayakanpesawatsinarxterhadapproyeksipaposteroanteriordanlatlateralpadateknikpemeriksaanfotothorax