Conoid tubercle angle: attention should be paid to supraclavicular plate fixation

Abstract Background The surgical protocol of ORIF for the treatment of mid-shaft clavicle fractures is common. However, poor plate fit or overhang usually occurs when the straight plate is selected for superior fixation. This is because the upper edge of the clavicle is not flat but has an angulatio...

Full description

Bibliographic Details
Main Authors: Bin Zhao, Wenqian Zhao, Isaac Assan, Rongxiu Bi
Format: Article
Language:English
Published: BMC 2022-02-01
Series:Journal of Orthopaedic Surgery and Research
Subjects:
Online Access:https://doi.org/10.1186/s13018-022-03003-w
_version_ 1828147278868643840
author Bin Zhao
Wenqian Zhao
Isaac Assan
Rongxiu Bi
author_facet Bin Zhao
Wenqian Zhao
Isaac Assan
Rongxiu Bi
author_sort Bin Zhao
collection DOAJ
description Abstract Background The surgical protocol of ORIF for the treatment of mid-shaft clavicle fractures is common. However, poor plate fit or overhang usually occurs when the straight plate is selected for superior fixation. This is because the upper edge of the clavicle is not flat but has an angulation near the conoid tubercle. We termed that angulation, conoid tubercle angle (CTA). Supposed the straight plate is forcibly attached to the surface of the clavicle, it will potentially cause misalignment of the fracture end and with that comes a change of CTA. In this case, choosing the contoured plate, such as a commercial pre-contoured anatomic plate or manual-contoured plate, for superior fixation seems to meet the requirements for both plate fit and fracture alignment. Hence, we retrospectively compared the radiological parameters, including the plate overhang, and the alignment of the fractures reflected by the CTA, between the contoured plate (CP) and straight plate (SP) groups, to draw attention to the CTA and its effects to supraclavicular plate fixation. Methods From March 2018 to April 2021, 217 patients with clavicle fractures that met the inclusion criteria but not the exclusion criteria were included in our study. 112 patients were enrolled into the straight plate group (SP) and 105 patients into the contoured plate group (CP). Besides that, 154 healthy adults were recruited into the health group (HA). Results Patients were followed up for 6 to 40 months postoperative. A normal CTA (164.54 ± 4.78°) was obtained from the HA group. There were 50 cases with plate overhang in the SP group, which presented a statistical difference in comparison with the CP group. The value of CTA (169.65 ± 5.84°) in the SP group also indicated a statistical difference in comparison with the normal CTA. Subgroup analysis showed that the CTA (165.88 ± 5.42°) in the overhang subgroup (O) had no statistical difference in comparison with the normal CTA, but the CTA (172.68 ± 4.18°) in the non-overhang subgroup (N-O) had. 3 cases experienced non-traumatic re-fracture (within 3 months after the removal of the fixation) in the O subgroup; 10 cases experienced a poor reduction in the N-O subgroup. In the CP group, the CTA was 166.79 ± 5.68°, which indicated a statistical difference with the SP group. Subgroup analysis was performed, including the manual-contoured plate subgroup (M-C) and commercial pre-contoured anatomic plate subgroup (P-C). The value of CTA (M-C, 166.97 ± 6.33°; P-C, 166.44 ± 6.33°) manifested a statistical difference in comparison with the N-O subgroup. 2 and 8 cases, respectively, had screw loosening and poor reduction in the M-C subgroup. No postoperative complication occurred in the P-C subgroup. Conclusion CTA is a useful reference in the evaluation of the reduction obtained on radiographic examination, and a reference guiding the plate contouring. The commercial pre-contoured anatomic plate provides a normal CTA and well fits the biomechanical characteristics of the clavicle, which can be recommended for superior fixation.
first_indexed 2024-04-11T20:57:44Z
format Article
id doaj.art-d5262b19db3b4d3282ce22971dea8290
institution Directory Open Access Journal
issn 1749-799X
language English
last_indexed 2024-04-11T20:57:44Z
publishDate 2022-02-01
publisher BMC
record_format Article
series Journal of Orthopaedic Surgery and Research
spelling doaj.art-d5262b19db3b4d3282ce22971dea82902022-12-22T04:03:37ZengBMCJournal of Orthopaedic Surgery and Research1749-799X2022-02-011711810.1186/s13018-022-03003-wConoid tubercle angle: attention should be paid to supraclavicular plate fixationBin Zhao0Wenqian Zhao1Isaac Assan2Rongxiu Bi3Postdoctoral Research Station, Shandong University of Traditional Chinese MedicineWeifang Key Laboratory for the Prevention and Treatment of Geriatric DiseasesCollege of Medicine and Veterinary Medicine, Deanery of Molecular, Genetic and Population Health Sciences, The University of EdinburghDepartment of Orthopedics, Affiliated Hospital of Shandong University of Traditional Chinese MedicineAbstract Background The surgical protocol of ORIF for the treatment of mid-shaft clavicle fractures is common. However, poor plate fit or overhang usually occurs when the straight plate is selected for superior fixation. This is because the upper edge of the clavicle is not flat but has an angulation near the conoid tubercle. We termed that angulation, conoid tubercle angle (CTA). Supposed the straight plate is forcibly attached to the surface of the clavicle, it will potentially cause misalignment of the fracture end and with that comes a change of CTA. In this case, choosing the contoured plate, such as a commercial pre-contoured anatomic plate or manual-contoured plate, for superior fixation seems to meet the requirements for both plate fit and fracture alignment. Hence, we retrospectively compared the radiological parameters, including the plate overhang, and the alignment of the fractures reflected by the CTA, between the contoured plate (CP) and straight plate (SP) groups, to draw attention to the CTA and its effects to supraclavicular plate fixation. Methods From March 2018 to April 2021, 217 patients with clavicle fractures that met the inclusion criteria but not the exclusion criteria were included in our study. 112 patients were enrolled into the straight plate group (SP) and 105 patients into the contoured plate group (CP). Besides that, 154 healthy adults were recruited into the health group (HA). Results Patients were followed up for 6 to 40 months postoperative. A normal CTA (164.54 ± 4.78°) was obtained from the HA group. There were 50 cases with plate overhang in the SP group, which presented a statistical difference in comparison with the CP group. The value of CTA (169.65 ± 5.84°) in the SP group also indicated a statistical difference in comparison with the normal CTA. Subgroup analysis showed that the CTA (165.88 ± 5.42°) in the overhang subgroup (O) had no statistical difference in comparison with the normal CTA, but the CTA (172.68 ± 4.18°) in the non-overhang subgroup (N-O) had. 3 cases experienced non-traumatic re-fracture (within 3 months after the removal of the fixation) in the O subgroup; 10 cases experienced a poor reduction in the N-O subgroup. In the CP group, the CTA was 166.79 ± 5.68°, which indicated a statistical difference with the SP group. Subgroup analysis was performed, including the manual-contoured plate subgroup (M-C) and commercial pre-contoured anatomic plate subgroup (P-C). The value of CTA (M-C, 166.97 ± 6.33°; P-C, 166.44 ± 6.33°) manifested a statistical difference in comparison with the N-O subgroup. 2 and 8 cases, respectively, had screw loosening and poor reduction in the M-C subgroup. No postoperative complication occurred in the P-C subgroup. Conclusion CTA is a useful reference in the evaluation of the reduction obtained on radiographic examination, and a reference guiding the plate contouring. The commercial pre-contoured anatomic plate provides a normal CTA and well fits the biomechanical characteristics of the clavicle, which can be recommended for superior fixation.https://doi.org/10.1186/s13018-022-03003-wConoid tubercle anglePre-contoured anatomic plateStraight plate
spellingShingle Bin Zhao
Wenqian Zhao
Isaac Assan
Rongxiu Bi
Conoid tubercle angle: attention should be paid to supraclavicular plate fixation
Journal of Orthopaedic Surgery and Research
Conoid tubercle angle
Pre-contoured anatomic plate
Straight plate
title Conoid tubercle angle: attention should be paid to supraclavicular plate fixation
title_full Conoid tubercle angle: attention should be paid to supraclavicular plate fixation
title_fullStr Conoid tubercle angle: attention should be paid to supraclavicular plate fixation
title_full_unstemmed Conoid tubercle angle: attention should be paid to supraclavicular plate fixation
title_short Conoid tubercle angle: attention should be paid to supraclavicular plate fixation
title_sort conoid tubercle angle attention should be paid to supraclavicular plate fixation
topic Conoid tubercle angle
Pre-contoured anatomic plate
Straight plate
url https://doi.org/10.1186/s13018-022-03003-w
work_keys_str_mv AT binzhao conoidtubercleangleattentionshouldbepaidtosupraclavicularplatefixation
AT wenqianzhao conoidtubercleangleattentionshouldbepaidtosupraclavicularplatefixation
AT isaacassan conoidtubercleangleattentionshouldbepaidtosupraclavicularplatefixation
AT rongxiubi conoidtubercleangleattentionshouldbepaidtosupraclavicularplatefixation