Electrochemical detection of folic acid using a modified screen printed electrode

In this work, an electrochemical sensor was established for the detection of folic acid based on Ni-BTC (BTC = benzene-1,3,5-tricarboxylic acid) metal-organic framework (MOF) modified screen-printed electrode (SPE). Electrochemical techniques (cyclic voltammetry (CV), differential pulse voltammetry...

Full description

Bibliographic Details
Main Authors: Sayed Zia Mohammadi, Farideh Mousazadeh, Maryam Mohammadhasani-Pour
Format: Article
Language:English
Published: International Association of Physical Chemists (IAPC) 2022-07-01
Series:Journal of Electrochemical Science and Engineering
Subjects:
Online Access:http://pub.iapchem.org/ojs/index.php/JESE/article/view/1360
_version_ 1811222761603858432
author Sayed Zia Mohammadi
Farideh Mousazadeh
Maryam Mohammadhasani-Pour
author_facet Sayed Zia Mohammadi
Farideh Mousazadeh
Maryam Mohammadhasani-Pour
author_sort Sayed Zia Mohammadi
collection DOAJ
description In this work, an electrochemical sensor was established for the detection of folic acid based on Ni-BTC (BTC = benzene-1,3,5-tricarboxylic acid) metal-organic framework (MOF) modified screen-printed electrode (SPE). Electrochemical techniques (cyclic voltammetry (CV), differential pulse voltammetry (DPV), linear sweep voltammetry (LSV) and chrono­ampere­metry (CHA) were used for the detection of folic acid at Ni-BTC MOF modified SPE. The results indicate that the as-prepared sensor has a good electrocatalytic effect on the detection of folic acid. This electrochemical sensor showed a dynamic linear response range from 0.08 to 635.0 µM and the detection limit was estimated to be 0.03±0.001 µM. Moreover, the feasibility of Ni-BTC MOF/SPE sensor to detect folic acid in real samples was also evaluated by the standard addition method.
first_indexed 2024-04-12T08:20:20Z
format Article
id doaj.art-d56a72690de54961a48c83d45b3bbd35
institution Directory Open Access Journal
issn 1847-9286
language English
last_indexed 2024-04-12T08:20:20Z
publishDate 2022-07-01
publisher International Association of Physical Chemists (IAPC)
record_format Article
series Journal of Electrochemical Science and Engineering
spelling doaj.art-d56a72690de54961a48c83d45b3bbd352022-12-22T03:40:36ZengInternational Association of Physical Chemists (IAPC)Journal of Electrochemical Science and Engineering1847-92862022-07-0110.5599/jese.1360Electrochemical detection of folic acid using a modified screen printed electrodeSayed Zia Mohammadi0Farideh Mousazadeh1Maryam Mohammadhasani-Pour2School of Medicine, Bam University of Medical Sciences , Bam, IranSchool of Medicine, Bam University of Medical Sciences , Bam, IranDepartment of Chemistry, Payame Nour University, Tehran, Iran In this work, an electrochemical sensor was established for the detection of folic acid based on Ni-BTC (BTC = benzene-1,3,5-tricarboxylic acid) metal-organic framework (MOF) modified screen-printed electrode (SPE). Electrochemical techniques (cyclic voltammetry (CV), differential pulse voltammetry (DPV), linear sweep voltammetry (LSV) and chrono­ampere­metry (CHA) were used for the detection of folic acid at Ni-BTC MOF modified SPE. The results indicate that the as-prepared sensor has a good electrocatalytic effect on the detection of folic acid. This electrochemical sensor showed a dynamic linear response range from 0.08 to 635.0 µM and the detection limit was estimated to be 0.03±0.001 µM. Moreover, the feasibility of Ni-BTC MOF/SPE sensor to detect folic acid in real samples was also evaluated by the standard addition method. http://pub.iapchem.org/ojs/index.php/JESE/article/view/1360Electrochemical sensorNi-BTC metal-organic frameworkvoltammetry
spellingShingle Sayed Zia Mohammadi
Farideh Mousazadeh
Maryam Mohammadhasani-Pour
Electrochemical detection of folic acid using a modified screen printed electrode
Journal of Electrochemical Science and Engineering
Electrochemical sensor
Ni-BTC metal-organic framework
voltammetry
title Electrochemical detection of folic acid using a modified screen printed electrode
title_full Electrochemical detection of folic acid using a modified screen printed electrode
title_fullStr Electrochemical detection of folic acid using a modified screen printed electrode
title_full_unstemmed Electrochemical detection of folic acid using a modified screen printed electrode
title_short Electrochemical detection of folic acid using a modified screen printed electrode
title_sort electrochemical detection of folic acid using a modified screen printed electrode
topic Electrochemical sensor
Ni-BTC metal-organic framework
voltammetry
url http://pub.iapchem.org/ojs/index.php/JESE/article/view/1360
work_keys_str_mv AT sayedziamohammadi electrochemicaldetectionoffolicacidusingamodifiedscreenprintedelectrode
AT faridehmousazadeh electrochemicaldetectionoffolicacidusingamodifiedscreenprintedelectrode
AT maryammohammadhasanipour electrochemicaldetectionoffolicacidusingamodifiedscreenprintedelectrode