Loop-Mediated Isothermal Amplification Assay for Rapid and Reliable Detection of Mycobacterium tuberculosis in Sputum Samples

Introduction: Tuberculosis (TB) remains a major global health problem. The most common method for diagnosing TB in developing countries is sputum smear microscopy; however, the sensitivity of this test is relatively lower. Detection of Mycobacterium tuberculosis using conventional culture and bioche...

Full description

Bibliographic Details
Main Authors: B K Sharma, B D Pandey, K Sharma, B Sapkota, A Singh, N Adhikari, B Maharjan
Format: Article
Language:English
Published: Gandaki Medical College Teaching Hospital & Research Centre Pvt. Ltd. 2018-08-01
Series:Journal of Gandaki Medical College
Subjects:
Online Access:https://www.nepjol.info/index.php/JGMCN/article/view/20805
_version_ 1797449654205415424
author B K Sharma
B D Pandey
K Sharma
B Sapkota
A Singh
N Adhikari
B Maharjan
author_facet B K Sharma
B D Pandey
K Sharma
B Sapkota
A Singh
N Adhikari
B Maharjan
author_sort B K Sharma
collection DOAJ
description Introduction: Tuberculosis (TB) remains a major global health problem. The most common method for diagnosing TB in developing countries is sputum smear microscopy; however, the sensitivity of this test is relatively lower. Detection of Mycobacterium tuberculosis using conventional culture and biochemical-based assays is time-consuming and laborious. Polymerase Chain Reaction (PCR) is also available for diagnosis of Mycobacterium tuberculosis. However, the PCR assay requires an expensive thermal cycler to amplify the DNA fragment in multiple temperature-dependent steps. Therefore, a simple and sensitive method for rapid detection has been anxiously awaited. The loop-mediated isothermal amplification (LAMP) assay is a diagnostic technique which can aid in the fight against TB in resource-poor countries. The LAMP assay can amplify a targeted sequence at a constant temperature. Therefore, a large and costly thermal cycler is not necessary for a LAMP assay. Objectives: The objective of this study was to identify Mycobacterium tuberculosis directly from sputum by LAMP and to compare its efficacy over routinely used methods. Methods: A total of 106 (53 fluorochrome staining positive and 53 fluorochrome staining negative) sputum samples were collected in this study. Mycobacterial DNA was extracted from concentrated sputum samples by freezing and boiling method. LAMP assay using a set of six specific primers targeting the M. tuberculosis 16S rRNA gene with high sensitivity was used to analyze sputum samples. The results were then compared with that of the culture method, which was considered as the gold standard method. Results: Among total of 106 samples studied by microscopy and culture, 53 were positive by both, whole four were positive by culture but negative by microscopy. With reference to culture, the microscopy had sensitivity 92.98%, specificity 100%, and predictive value of positive test 100%, predictive value of negative test 92.5%. Out of 106 samples subjected to culture and LAMP for the diagnosis of TB, 55 samples were positive by both tests and two were positive only in culture, while 48 were negative in both tests and one was negative only in culture. While comparing the LAMP with culture as a gold standard, the sensitivity of LAMP was 96.49%, specificity was 97.95%, predictive value of positive test was 98.21%, predictive value of negative test was 96%. Conclusions: Comparative experiments showed that the LAMP assay is a rapid, sensitive, and specific method to detect M. tuberculosis infection. Indeed, an inexpensive LAMP assay would be potential as a diagnostic test for tuberculosis, especially in resource-limited settings. J-GMC-N | Volume 11 | Issue 01 | January-June 2018, Page: 27-34
first_indexed 2024-03-09T14:28:14Z
format Article
id doaj.art-d5bf4c3066764eb389899c88aeb1bce5
institution Directory Open Access Journal
issn 2070-4240
2070-4259
language English
last_indexed 2024-03-09T14:28:14Z
publishDate 2018-08-01
publisher Gandaki Medical College Teaching Hospital & Research Centre Pvt. Ltd.
record_format Article
series Journal of Gandaki Medical College
spelling doaj.art-d5bf4c3066764eb389899c88aeb1bce52023-11-28T05:00:20ZengGandaki Medical College Teaching Hospital & Research Centre Pvt. Ltd.Journal of Gandaki Medical College2070-42402070-42592018-08-01102273410.3126/jgmcn.v10i2.2080520805Loop-Mediated Isothermal Amplification Assay for Rapid and Reliable Detection of Mycobacterium tuberculosis in Sputum SamplesB K Sharma0B D Pandey1K Sharma2B Sapkota3A Singh4N Adhikari5B Maharjan6Department of Microbiology, Gandaki Medical College and Teaching Hospital, PokharaSukraraj Tropical and Infectious Disease Hospital & Everest International Clinic and Research Center, KathmanduDepartment of Radiology, Gandaki Medical College & Teaching Hospital, PokharaDepartment of Research and Biotechnology, Anandaban Hospital, KathmanduDepartment of Microbiology, Tribhuvan University, KirtipurDepartment of Microbiology, Tribhuvan University, KirtipurGerman-Nepal Tuberculosis Project (GENETUP), KathmanduIntroduction: Tuberculosis (TB) remains a major global health problem. The most common method for diagnosing TB in developing countries is sputum smear microscopy; however, the sensitivity of this test is relatively lower. Detection of Mycobacterium tuberculosis using conventional culture and biochemical-based assays is time-consuming and laborious. Polymerase Chain Reaction (PCR) is also available for diagnosis of Mycobacterium tuberculosis. However, the PCR assay requires an expensive thermal cycler to amplify the DNA fragment in multiple temperature-dependent steps. Therefore, a simple and sensitive method for rapid detection has been anxiously awaited. The loop-mediated isothermal amplification (LAMP) assay is a diagnostic technique which can aid in the fight against TB in resource-poor countries. The LAMP assay can amplify a targeted sequence at a constant temperature. Therefore, a large and costly thermal cycler is not necessary for a LAMP assay. Objectives: The objective of this study was to identify Mycobacterium tuberculosis directly from sputum by LAMP and to compare its efficacy over routinely used methods. Methods: A total of 106 (53 fluorochrome staining positive and 53 fluorochrome staining negative) sputum samples were collected in this study. Mycobacterial DNA was extracted from concentrated sputum samples by freezing and boiling method. LAMP assay using a set of six specific primers targeting the M. tuberculosis 16S rRNA gene with high sensitivity was used to analyze sputum samples. The results were then compared with that of the culture method, which was considered as the gold standard method. Results: Among total of 106 samples studied by microscopy and culture, 53 were positive by both, whole four were positive by culture but negative by microscopy. With reference to culture, the microscopy had sensitivity 92.98%, specificity 100%, and predictive value of positive test 100%, predictive value of negative test 92.5%. Out of 106 samples subjected to culture and LAMP for the diagnosis of TB, 55 samples were positive by both tests and two were positive only in culture, while 48 were negative in both tests and one was negative only in culture. While comparing the LAMP with culture as a gold standard, the sensitivity of LAMP was 96.49%, specificity was 97.95%, predictive value of positive test was 98.21%, predictive value of negative test was 96%. Conclusions: Comparative experiments showed that the LAMP assay is a rapid, sensitive, and specific method to detect M. tuberculosis infection. Indeed, an inexpensive LAMP assay would be potential as a diagnostic test for tuberculosis, especially in resource-limited settings. J-GMC-N | Volume 11 | Issue 01 | January-June 2018, Page: 27-34https://www.nepjol.info/index.php/JGMCN/article/view/20805cultureloop-mediated isothermal amplificationmicroscopymycobacterium tuberculosispolymerase chain reaction
spellingShingle B K Sharma
B D Pandey
K Sharma
B Sapkota
A Singh
N Adhikari
B Maharjan
Loop-Mediated Isothermal Amplification Assay for Rapid and Reliable Detection of Mycobacterium tuberculosis in Sputum Samples
Journal of Gandaki Medical College
culture
loop-mediated isothermal amplification
microscopy
mycobacterium tuberculosis
polymerase chain reaction
title Loop-Mediated Isothermal Amplification Assay for Rapid and Reliable Detection of Mycobacterium tuberculosis in Sputum Samples
title_full Loop-Mediated Isothermal Amplification Assay for Rapid and Reliable Detection of Mycobacterium tuberculosis in Sputum Samples
title_fullStr Loop-Mediated Isothermal Amplification Assay for Rapid and Reliable Detection of Mycobacterium tuberculosis in Sputum Samples
title_full_unstemmed Loop-Mediated Isothermal Amplification Assay for Rapid and Reliable Detection of Mycobacterium tuberculosis in Sputum Samples
title_short Loop-Mediated Isothermal Amplification Assay for Rapid and Reliable Detection of Mycobacterium tuberculosis in Sputum Samples
title_sort loop mediated isothermal amplification assay for rapid and reliable detection of mycobacterium tuberculosis in sputum samples
topic culture
loop-mediated isothermal amplification
microscopy
mycobacterium tuberculosis
polymerase chain reaction
url https://www.nepjol.info/index.php/JGMCN/article/view/20805
work_keys_str_mv AT bksharma loopmediatedisothermalamplificationassayforrapidandreliabledetectionofmycobacteriumtuberculosisinsputumsamples
AT bdpandey loopmediatedisothermalamplificationassayforrapidandreliabledetectionofmycobacteriumtuberculosisinsputumsamples
AT ksharma loopmediatedisothermalamplificationassayforrapidandreliabledetectionofmycobacteriumtuberculosisinsputumsamples
AT bsapkota loopmediatedisothermalamplificationassayforrapidandreliabledetectionofmycobacteriumtuberculosisinsputumsamples
AT asingh loopmediatedisothermalamplificationassayforrapidandreliabledetectionofmycobacteriumtuberculosisinsputumsamples
AT nadhikari loopmediatedisothermalamplificationassayforrapidandreliabledetectionofmycobacteriumtuberculosisinsputumsamples
AT bmaharjan loopmediatedisothermalamplificationassayforrapidandreliabledetectionofmycobacteriumtuberculosisinsputumsamples