Numerical Study of the Effects of Aneurysm and Stenosis in the Left Coronary Artery on the Human Blood Stream

The heart is the most important muscular organ in human's body, which pumps blood through the arteries to supply the body with oxygen and nutrients. The heart is supplied by the coronary blood vessel; therefore, the effect of aneurysm and stenosis in left coronary artery on the velocity of bloo...

Full description

Bibliographic Details
Main Authors: N Mahmoud, A AI.allaq
Format: Article
Language:English
Published: Unviversity of Technology- Iraq 2017-01-01
Series:Engineering and Technology Journal
Subjects:
Online Access:https://etj.uotechnology.edu.iq/article_127308_408c7a7c4c8f349097b98b49b393cf2c.pdf
_version_ 1797325972605763584
author N Mahmoud
A AI.allaq
author_facet N Mahmoud
A AI.allaq
author_sort N Mahmoud
collection DOAJ
description The heart is the most important muscular organ in human's body, which pumps blood through the arteries to supply the body with oxygen and nutrients. The heart is supplied by the coronary blood vessel; therefore, the effect of aneurysm and stenosis in left coronary artery on the velocity of blood, wall shear stress of artery and mass flow rate of blood have been investigated in this study. The simulation program (ANSYS Fluent) was used to execute the numerical study. Typical geometry of left coronary artery and physiological parameters of human blood values were obtained from measured values reported in literature. The problem of the effect of the aneurysm and stenosis on the human blood stream has been solved numerically under three conditions, healthy artery and two infected cases (30%, 50%) percentage of aneurysm in left main stem (LMS) and stenosis in left anterior descending (LAD). It has been shown, in stenosis region that the velocity of blood will suffer fast flowing and an increase in the shear stress on the artery wall, in contrast with the aneurysm case, blood velocity becomes slow and low wall shear stress. Also irregularity was shown in mass flow rate of blood in the left coronary artery which suffers from aneurysm and stenosis compared with healthy artery.
first_indexed 2024-03-08T06:17:54Z
format Article
id doaj.art-d5ec20cf464045be9b641a17ed7ca1fe
institution Directory Open Access Journal
issn 1681-6900
2412-0758
language English
last_indexed 2024-03-08T06:17:54Z
publishDate 2017-01-01
publisher Unviversity of Technology- Iraq
record_format Article
series Engineering and Technology Journal
spelling doaj.art-d5ec20cf464045be9b641a17ed7ca1fe2024-02-04T17:18:59ZengUnviversity of Technology- IraqEngineering and Technology Journal1681-69002412-07582017-01-01351A294010.30684/etj.2017.127308127308Numerical Study of the Effects of Aneurysm and Stenosis in the Left Coronary Artery on the Human Blood StreamN Mahmoud0A AI.allaq1Mechanical Engineering Dept. University of Technology , Baghdad , IraqMinistry of High Education and Scientific Research , Office Reconstruction and Projects Baghdad, IraqThe heart is the most important muscular organ in human's body, which pumps blood through the arteries to supply the body with oxygen and nutrients. The heart is supplied by the coronary blood vessel; therefore, the effect of aneurysm and stenosis in left coronary artery on the velocity of blood, wall shear stress of artery and mass flow rate of blood have been investigated in this study. The simulation program (ANSYS Fluent) was used to execute the numerical study. Typical geometry of left coronary artery and physiological parameters of human blood values were obtained from measured values reported in literature. The problem of the effect of the aneurysm and stenosis on the human blood stream has been solved numerically under three conditions, healthy artery and two infected cases (30%, 50%) percentage of aneurysm in left main stem (LMS) and stenosis in left anterior descending (LAD). It has been shown, in stenosis region that the velocity of blood will suffer fast flowing and an increase in the shear stress on the artery wall, in contrast with the aneurysm case, blood velocity becomes slow and low wall shear stress. Also irregularity was shown in mass flow rate of blood in the left coronary artery which suffers from aneurysm and stenosis compared with healthy artery.https://etj.uotechnology.edu.iq/article_127308_408c7a7c4c8f349097b98b49b393cf2c.pdfaneurysmblood velocitycoronary artery diseasecfdmass flow ratestenosiswall shear stress
spellingShingle N Mahmoud
A AI.allaq
Numerical Study of the Effects of Aneurysm and Stenosis in the Left Coronary Artery on the Human Blood Stream
Engineering and Technology Journal
aneurysm
blood velocity
coronary artery disease
cfd
mass flow rate
stenosis
wall shear stress
title Numerical Study of the Effects of Aneurysm and Stenosis in the Left Coronary Artery on the Human Blood Stream
title_full Numerical Study of the Effects of Aneurysm and Stenosis in the Left Coronary Artery on the Human Blood Stream
title_fullStr Numerical Study of the Effects of Aneurysm and Stenosis in the Left Coronary Artery on the Human Blood Stream
title_full_unstemmed Numerical Study of the Effects of Aneurysm and Stenosis in the Left Coronary Artery on the Human Blood Stream
title_short Numerical Study of the Effects of Aneurysm and Stenosis in the Left Coronary Artery on the Human Blood Stream
title_sort numerical study of the effects of aneurysm and stenosis in the left coronary artery on the human blood stream
topic aneurysm
blood velocity
coronary artery disease
cfd
mass flow rate
stenosis
wall shear stress
url https://etj.uotechnology.edu.iq/article_127308_408c7a7c4c8f349097b98b49b393cf2c.pdf
work_keys_str_mv AT nmahmoud numericalstudyoftheeffectsofaneurysmandstenosisintheleftcoronaryarteryonthehumanbloodstream
AT aaiallaq numericalstudyoftheeffectsofaneurysmandstenosisintheleftcoronaryarteryonthehumanbloodstream