Reactive power adjustable ability of HVDC under steady state condition

The high voltage direct current (HVDC) converter has a certain dynamic reactive power regulation ability. Making full use of the reactive power regulation ability of the converter station can significantly improve the stability of the HVDC. In this paper, the adjustable capability of reactive power...

Full description

Bibliographic Details
Main Authors: GUAN Xiaoyu, WANG Juanjuan, HE Qihao
Format: Article
Language:zho
Published: Editorial Department of Electric Power Engineering Technology 2024-01-01
Series:电力工程技术
Subjects:
Online Access:https://www.epet-info.com/dlgcjsen/article/abstract/230224165
_version_ 1797346896522510336
author GUAN Xiaoyu
WANG Juanjuan
HE Qihao
author_facet GUAN Xiaoyu
WANG Juanjuan
HE Qihao
author_sort GUAN Xiaoyu
collection DOAJ
description The high voltage direct current (HVDC) converter has a certain dynamic reactive power regulation ability. Making full use of the reactive power regulation ability of the converter station can significantly improve the stability of the HVDC. In this paper, the adjustable capability of reactive power of HVDC during steady-state operation is studied, and the coupling characteristics of active power and reactive power are analyzed. Taking conference International des grands reseaux electriques (CIGRE) HVDC standard test model and Guiguan Ⅱ direct current transmission engineering model as examples, the operating range of direct current under steady-state condition is analyzed, and then the adjustable capability of reactive power on both sides of rectifier and inverter is obtained and applied in reactive power control. It is found that CIGRE HVDC standard test model has similar regulating capacity of capacitive reactive power and inductive reactive power, while regulating capacity of inductive reactive power is higher than that of capacitive reactive power in Guiguang Ⅱ direct current transmission engineering model. The application value of reactive power adjustable capability is verified in electromagnetic transient simulation program PSCAD/EMTDC.
first_indexed 2024-03-08T11:39:51Z
format Article
id doaj.art-d63c1febe11541a0bb748b487b66d7a4
institution Directory Open Access Journal
issn 2096-3203
language zho
last_indexed 2024-03-08T11:39:51Z
publishDate 2024-01-01
publisher Editorial Department of Electric Power Engineering Technology
record_format Article
series 电力工程技术
spelling doaj.art-d63c1febe11541a0bb748b487b66d7a42024-01-25T07:27:35ZzhoEditorial Department of Electric Power Engineering Technology电力工程技术2096-32032024-01-0143110010710.12158/j.2096-3203.2024.01.011230224165Reactive power adjustable ability of HVDC under steady state conditionGUAN Xiaoyu0WANG Juanjuan1HE Qihao2School of Electric Power, South China University of Technology, Guangzhou 510641, ChinaSchool of Electric Power, South China University of Technology, Guangzhou 510641, ChinaSchool of Electric Power, South China University of Technology, Guangzhou 510641, ChinaThe high voltage direct current (HVDC) converter has a certain dynamic reactive power regulation ability. Making full use of the reactive power regulation ability of the converter station can significantly improve the stability of the HVDC. In this paper, the adjustable capability of reactive power of HVDC during steady-state operation is studied, and the coupling characteristics of active power and reactive power are analyzed. Taking conference International des grands reseaux electriques (CIGRE) HVDC standard test model and Guiguan Ⅱ direct current transmission engineering model as examples, the operating range of direct current under steady-state condition is analyzed, and then the adjustable capability of reactive power on both sides of rectifier and inverter is obtained and applied in reactive power control. It is found that CIGRE HVDC standard test model has similar regulating capacity of capacitive reactive power and inductive reactive power, while regulating capacity of inductive reactive power is higher than that of capacitive reactive power in Guiguang Ⅱ direct current transmission engineering model. The application value of reactive power adjustable capability is verified in electromagnetic transient simulation program PSCAD/EMTDC.https://www.epet-info.com/dlgcjsen/article/abstract/230224165high voltage direct current(hvdc)steady state conditiondirect currentactive powerac bus voltagereactive power
spellingShingle GUAN Xiaoyu
WANG Juanjuan
HE Qihao
Reactive power adjustable ability of HVDC under steady state condition
电力工程技术
high voltage direct current(hvdc)
steady state condition
direct current
active power
ac bus voltage
reactive power
title Reactive power adjustable ability of HVDC under steady state condition
title_full Reactive power adjustable ability of HVDC under steady state condition
title_fullStr Reactive power adjustable ability of HVDC under steady state condition
title_full_unstemmed Reactive power adjustable ability of HVDC under steady state condition
title_short Reactive power adjustable ability of HVDC under steady state condition
title_sort reactive power adjustable ability of hvdc under steady state condition
topic high voltage direct current(hvdc)
steady state condition
direct current
active power
ac bus voltage
reactive power
url https://www.epet-info.com/dlgcjsen/article/abstract/230224165
work_keys_str_mv AT guanxiaoyu reactivepoweradjustableabilityofhvdcundersteadystatecondition
AT wangjuanjuan reactivepoweradjustableabilityofhvdcundersteadystatecondition
AT heqihao reactivepoweradjustableabilityofhvdcundersteadystatecondition