Validation of Fully Automated VMAT Plan Generation for Library-Based Plan-of-the-Day Cervical Cancer Radiotherapy.

To develop and validate fully automated generation of VMAT plan-libraries for plan-of-the-day adaptive radiotherapy in locally-advanced cervical cancer.Our framework for fully automated treatment plan generation (Erasmus-iCycle) was adapted to create dual-arc VMAT treatment plan libraries for cervic...

Full description

Bibliographic Details
Main Authors: Abdul Wahab M Sharfo, Sebastiaan Breedveld, Peter W J Voet, Sabrina T Heijkoop, Jan-Willem M Mens, Mischa S Hoogeman, Ben J M Heijmen
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2016-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC5199117?pdf=render
_version_ 1818616071457865728
author Abdul Wahab M Sharfo
Sebastiaan Breedveld
Peter W J Voet
Sabrina T Heijkoop
Jan-Willem M Mens
Mischa S Hoogeman
Ben J M Heijmen
author_facet Abdul Wahab M Sharfo
Sebastiaan Breedveld
Peter W J Voet
Sabrina T Heijkoop
Jan-Willem M Mens
Mischa S Hoogeman
Ben J M Heijmen
author_sort Abdul Wahab M Sharfo
collection DOAJ
description To develop and validate fully automated generation of VMAT plan-libraries for plan-of-the-day adaptive radiotherapy in locally-advanced cervical cancer.Our framework for fully automated treatment plan generation (Erasmus-iCycle) was adapted to create dual-arc VMAT treatment plan libraries for cervical cancer patients. For each of 34 patients, automatically generated VMAT plans (autoVMAT) were compared to manually generated, clinically delivered 9-beam IMRT plans (CLINICAL), and to dual-arc VMAT plans generated manually by an expert planner (manVMAT). Furthermore, all plans were benchmarked against 20-beam equi-angular IMRT plans (autoIMRT). For all plans, a PTV coverage of 99.5% by at least 95% of the prescribed dose (46 Gy) had the highest planning priority, followed by minimization of V45Gy for small bowel (SB). Other OARs considered were bladder, rectum, and sigmoid.All plans had a highly similar PTV coverage, within the clinical constraints (above). After plan normalizations for exactly equal median PTV doses in corresponding plans, all evaluated OAR parameters in autoVMAT plans were on average lower than in the CLINICAL plans with an average reduction in SB V45Gy of 34.6% (p<0.001). For 41/44 autoVMAT plans, SB V45Gy was lower than for manVMAT (p<0.001, average reduction 30.3%), while SB V15Gy increased by 2.3% (p = 0.011). AutoIMRT reduced SB V45Gy by another 2.7% compared to autoVMAT, while also resulting in a 9.0% reduction in SB V15Gy (p<0.001), but with a prolonged delivery time. Differences between manVMAT and autoVMAT in bladder, rectal and sigmoid doses were ≤ 1%. Improvements in SB dose delivery with autoVMAT instead of manVMAT were higher for empty bladder PTVs compared to full bladder PTVs, due to differences in concavity of the PTVs.Quality of automatically generated VMAT plans was superior to manually generated plans. Automatic VMAT plan generation for cervical cancer has been implemented in our clinical routine. Due to the achieved workload reduction, extension of plan libraries has become feasible.
first_indexed 2024-12-16T16:43:58Z
format Article
id doaj.art-d65b9a39989f419089918fd132b66513
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-12-16T16:43:58Z
publishDate 2016-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-d65b9a39989f419089918fd132b665132022-12-21T22:24:14ZengPublic Library of Science (PLoS)PLoS ONE1932-62032016-01-011112e016920210.1371/journal.pone.0169202Validation of Fully Automated VMAT Plan Generation for Library-Based Plan-of-the-Day Cervical Cancer Radiotherapy.Abdul Wahab M SharfoSebastiaan BreedveldPeter W J VoetSabrina T HeijkoopJan-Willem M MensMischa S HoogemanBen J M HeijmenTo develop and validate fully automated generation of VMAT plan-libraries for plan-of-the-day adaptive radiotherapy in locally-advanced cervical cancer.Our framework for fully automated treatment plan generation (Erasmus-iCycle) was adapted to create dual-arc VMAT treatment plan libraries for cervical cancer patients. For each of 34 patients, automatically generated VMAT plans (autoVMAT) were compared to manually generated, clinically delivered 9-beam IMRT plans (CLINICAL), and to dual-arc VMAT plans generated manually by an expert planner (manVMAT). Furthermore, all plans were benchmarked against 20-beam equi-angular IMRT plans (autoIMRT). For all plans, a PTV coverage of 99.5% by at least 95% of the prescribed dose (46 Gy) had the highest planning priority, followed by minimization of V45Gy for small bowel (SB). Other OARs considered were bladder, rectum, and sigmoid.All plans had a highly similar PTV coverage, within the clinical constraints (above). After plan normalizations for exactly equal median PTV doses in corresponding plans, all evaluated OAR parameters in autoVMAT plans were on average lower than in the CLINICAL plans with an average reduction in SB V45Gy of 34.6% (p<0.001). For 41/44 autoVMAT plans, SB V45Gy was lower than for manVMAT (p<0.001, average reduction 30.3%), while SB V15Gy increased by 2.3% (p = 0.011). AutoIMRT reduced SB V45Gy by another 2.7% compared to autoVMAT, while also resulting in a 9.0% reduction in SB V15Gy (p<0.001), but with a prolonged delivery time. Differences between manVMAT and autoVMAT in bladder, rectal and sigmoid doses were ≤ 1%. Improvements in SB dose delivery with autoVMAT instead of manVMAT were higher for empty bladder PTVs compared to full bladder PTVs, due to differences in concavity of the PTVs.Quality of automatically generated VMAT plans was superior to manually generated plans. Automatic VMAT plan generation for cervical cancer has been implemented in our clinical routine. Due to the achieved workload reduction, extension of plan libraries has become feasible.http://europepmc.org/articles/PMC5199117?pdf=render
spellingShingle Abdul Wahab M Sharfo
Sebastiaan Breedveld
Peter W J Voet
Sabrina T Heijkoop
Jan-Willem M Mens
Mischa S Hoogeman
Ben J M Heijmen
Validation of Fully Automated VMAT Plan Generation for Library-Based Plan-of-the-Day Cervical Cancer Radiotherapy.
PLoS ONE
title Validation of Fully Automated VMAT Plan Generation for Library-Based Plan-of-the-Day Cervical Cancer Radiotherapy.
title_full Validation of Fully Automated VMAT Plan Generation for Library-Based Plan-of-the-Day Cervical Cancer Radiotherapy.
title_fullStr Validation of Fully Automated VMAT Plan Generation for Library-Based Plan-of-the-Day Cervical Cancer Radiotherapy.
title_full_unstemmed Validation of Fully Automated VMAT Plan Generation for Library-Based Plan-of-the-Day Cervical Cancer Radiotherapy.
title_short Validation of Fully Automated VMAT Plan Generation for Library-Based Plan-of-the-Day Cervical Cancer Radiotherapy.
title_sort validation of fully automated vmat plan generation for library based plan of the day cervical cancer radiotherapy
url http://europepmc.org/articles/PMC5199117?pdf=render
work_keys_str_mv AT abdulwahabmsharfo validationoffullyautomatedvmatplangenerationforlibrarybasedplanofthedaycervicalcancerradiotherapy
AT sebastiaanbreedveld validationoffullyautomatedvmatplangenerationforlibrarybasedplanofthedaycervicalcancerradiotherapy
AT peterwjvoet validationoffullyautomatedvmatplangenerationforlibrarybasedplanofthedaycervicalcancerradiotherapy
AT sabrinatheijkoop validationoffullyautomatedvmatplangenerationforlibrarybasedplanofthedaycervicalcancerradiotherapy
AT janwillemmmens validationoffullyautomatedvmatplangenerationforlibrarybasedplanofthedaycervicalcancerradiotherapy
AT mischashoogeman validationoffullyautomatedvmatplangenerationforlibrarybasedplanofthedaycervicalcancerradiotherapy
AT benjmheijmen validationoffullyautomatedvmatplangenerationforlibrarybasedplanofthedaycervicalcancerradiotherapy